Effect of platform design of dental implant abutment on loosening and fatigue performance

被引:0
作者
Sun, Fei [1 ]
Xu, Li-Bing [1 ]
Lai, Song-Xian [1 ]
Xu, Hai [2 ]
Li, Xin-Chang [1 ,2 ]
Lin, Zeng [1 ]
机构
[1] Northeastern Univ, Sch Mech Engn & Automat, Shenyang 110004, Peoples R China
[2] WEGO JERICOM Biomat Co Ltd, Weihai 264210, Peoples R China
基金
中国博士后科学基金;
关键词
Abutment; Structural design; Loosening; Fatigue; FEA; IN-VITRO; TORQUE; CONNECTIONS; SCREW; STRENGTH; SURVIVAL; HEXAGON; CYCLES;
D O I
10.1016/j.engfailanal.2024.109134
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Under the influence of daily occlusal forces, mechanical complications such as loose connections and fatigue damage are significant factors contributing to dental implant failure. The structural design of implant components is crucial in enhancing the long-term durability of implant systems. This research explores the impact of the platform structure of the abutment on connection loosening and fatigue properties. Four abutments with varying platform structures were designed and produced. The study involved testing and comparing screw loosening behavior before and after loading, as well as evaluating static load strength and fatigue characteristics. Observations were made on abutment surface wear and fatigue sections. A three-dimensional model was utilized to confirm damage location using the finite element method. Results indicate that the abutment's platform structure enhances anti-loosening performance and static failure load, while reducing fatigue life. Additionally, the position of fatigue fracture in the abutment is influenced by the load magnitude. The finite element analysis (FEA) findings align with the results of the static load tests.
引用
收藏
页数:12
相关论文
共 50 条
[41]   Zirconia as a Dental Implant Abutment Material: A Systematic Review [J].
Nakamura, Keisuke ;
Kanno, Taro ;
Milleding, Percy ;
Ortengren, Ulf .
INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2010, 23 (04) :299-309
[42]   Analytical and experimental position stability of the abutment in different dental implant systems with a conical implant-abutment connection [J].
Semper-Hogg, Wiebke ;
Kraft, Silvan ;
Stiller, Sebastian ;
Mehrhof, Juergen ;
Nelson, Katja .
CLINICAL ORAL INVESTIGATIONS, 2013, 17 (03) :1017-1023
[43]   Effect of elbow implant design parameters on loosening: A finite element analysis [J].
Heidari, Milad ;
Rahmanivahid, Pooyan ;
Sharifi, Sayyed Nabi Al-Din ;
Hashemi, Mehdi ;
Mohammadian, Erfan ;
Akbari, Amir ;
Razaviyan, Zahrapanah .
REVISTA INTERNACIONAL DE METODOS NUMERICOS PARA CALCULO Y DISENO EN INGENIERIA, 2020, 36 (01)
[44]   Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit [J].
Velez, Jorge ;
Pelaez, Jesus ;
Lopez-Suarez, Carlos ;
Agustin-Panadero, Ruben ;
Tobar, Celia ;
Suarez, Maria J. .
JOURNAL OF CLINICAL MEDICINE, 2020, 9 (08) :1-13
[45]   Effect of Implant-Abutment Connection Design on Load Bearing Capacity and Failure Mode of Implants [J].
Dittmer, Stephanie ;
Dittmer, Marc Philipp ;
Kohorst, Philipp ;
Jendras, Michael ;
Borchers, Lothar ;
Stiesch, Meike .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2011, 20 (07) :510-516
[46]   Maximum insertion torque of a novel implant-abutment-interface design for PEEK dental implants [J].
Schwitalla, Andreas Dominik ;
Zimmermann, Tycho ;
Spintig, Tobias ;
Abou-Emara, Mohamed ;
Lackmann, Justus ;
Mueller, Wolf-Dieter ;
Houshmand, Alireza .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 77 :85-89
[47]   Dynamic and static load performance of dental biomaterial systems with conical implant-abutment connections [J].
Basgil, Mehmet Can ;
Kurtoglu, Cem ;
Soygun, Koray ;
Uslan, Yunus ;
Demi, Teyfik R. .
BIO-MEDICAL MATERIALS AND ENGINEERING, 2020, 31 (05) :319-328
[48]   In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening [J].
Kose, Onur Dincer ;
Karatasli, Burcin ;
Demircan, Sabit ;
Kose, Taha Emre ;
Cene, Erhan ;
Aya, Serhan Aydjn ;
Erdem, Mehmet Ali ;
Cankaya, Abdulkadir Burak .
BIOMED RESEARCH INTERNATIONAL, 2017, 2017
[49]   The impact of Morse taper implant design on microleakage at implant-healing abutment interface [J].
Kim, Soyeon ;
Lee, Joo Won ;
Kim, Jae-Heon ;
Truong, Van Mai ;
Park, Young-Seok .
DENTAL MATERIALS JOURNAL, 2022, 41 (05) :767-773
[50]   Rotational Load Fatigue Performance of a One-Size Implant-Abutment Connection System [J].
Ang, Kai Yuit ;
Quek, Christopher ;
Fei, Frank Lee Kong ;
Seetoh, Yoong Liang ;
Tan, Li Wen ;
Tan, Keson Beng Choon .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2024, 39 (06) :e223-e233