Effect of platform design of dental implant abutment on loosening and fatigue performance

被引:0
作者
Sun, Fei [1 ]
Xu, Li-Bing [1 ]
Lai, Song-Xian [1 ]
Xu, Hai [2 ]
Li, Xin-Chang [1 ,2 ]
Lin, Zeng [1 ]
机构
[1] Northeastern Univ, Sch Mech Engn & Automat, Shenyang 110004, Peoples R China
[2] WEGO JERICOM Biomat Co Ltd, Weihai 264210, Peoples R China
基金
中国博士后科学基金;
关键词
Abutment; Structural design; Loosening; Fatigue; FEA; IN-VITRO; TORQUE; CONNECTIONS; SCREW; STRENGTH; SURVIVAL; HEXAGON; CYCLES;
D O I
10.1016/j.engfailanal.2024.109134
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Under the influence of daily occlusal forces, mechanical complications such as loose connections and fatigue damage are significant factors contributing to dental implant failure. The structural design of implant components is crucial in enhancing the long-term durability of implant systems. This research explores the impact of the platform structure of the abutment on connection loosening and fatigue properties. Four abutments with varying platform structures were designed and produced. The study involved testing and comparing screw loosening behavior before and after loading, as well as evaluating static load strength and fatigue characteristics. Observations were made on abutment surface wear and fatigue sections. A three-dimensional model was utilized to confirm damage location using the finite element method. Results indicate that the abutment's platform structure enhances anti-loosening performance and static failure load, while reducing fatigue life. Additionally, the position of fatigue fracture in the abutment is influenced by the load magnitude. The finite element analysis (FEA) findings align with the results of the static load tests.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Analysis of the abutment-implant platform gap in internal hex dental implants.
    Cardozo, Ricardo
    Olate, Sergio
    Navarro, Pablo
    Araya, Javier
    Gonzalez, Omar
    Carrasco, Juan
    Zenteno, Claudia
    BIOMEDICAL RESEARCH-INDIA, 2017, 28 (08): : 3336 - 3339
  • [22] Performance of different abutment/implant joints as a result of a sealing agent
    Seloto, Camila Berbel
    Strazzi-Sahyon, Henrico Badaoui
    dos Santos, Paulo Henrique
    Assuncao, Wirley Goncalves
    JOURNAL OF PROSTHODONTIC RESEARCH, 2021, 65 (04) : 489 - 494
  • [23] Differences in micromorphology of the implant-abutment junction for original and third-party abutments on a representative dental implant
    Fokas, George
    Ma, Li
    Chronopoulos, Vasilios
    Janda, Martin
    Mattheos, Nikos
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (01) : 143 - 150
  • [24] The effect of clockwise and counterclockwise twisting moments on abutment screw loosening
    Yao, Kuang-Ta
    Kao, Hung-Chan
    Cheng, Cheng-Kung
    Fang, Hsu-Wei
    Yip, Shing-Wai
    Hsu, Ming-Lun
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (10) : 1181 - 1186
  • [25] Influence of the Titanium Base Abutment Design on Monolithic Zirconia Multiple-Unit Implant Fixed Dental Prostheses: A Laboratory Study
    Calderon, Ulises
    Hicklin, Stefan Paul
    Mojon, Philippe
    Fehmer, Vincent
    Nesic, Dobrila
    Mekki, Mustapha
    Sailer, Irena
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (01) : 19 - 29
  • [26] Effect of PEEK and PTFE coatings in fatigue performance of dental implant retaining screw joint: An in vitro study
    Chen, Xi
    Ma, Ruiyang
    Min, Jie
    Li, Zhi
    Yu, Ping
    Yu, Haiyang
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 103 (103)
  • [27] Effect of Loading Angles on Abutment Screw Loosening: In Vitro Study
    Sun, Fei
    Xu, Li-Bing
    Lin, Zeng
    Jiang, Lu-Lu
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2025, 27 (01)
  • [28] Implant-abutment interface design affects fatigue and fracture strength of implants
    Steinebrunner, Lars
    Wolfart, Stefan
    Ludwig, Klaus
    Kern, Matthias
    CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (12) : 1276 - 1284
  • [29] Influence of the implant abutment types and the dynamic loading on initial screw loosening
    Kim, Eun-Sook
    Shin, Soo-Yeon
    JOURNAL OF ADVANCED PROSTHODONTICS, 2013, 5 (01) : 21 - 28
  • [30] Stability of implant-abutment connection in three different systems after fatigue test
    Bajoghli, Farshad
    Sabouhi, Mohmoud
    Pourali, Mohamad
    Davoudi, Amin
    THE JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2022, 22 (04) : 338 - 342