Application of the control methods for radiant floor cooling system in residential buildings

被引:82
|
作者
Department of Architecture, College of Engineering, Seoul National University, Seoul, Korea, Republic of [1 ]
不详 [2 ]
不详 [3 ]
机构
来源
Build. Environ. | 2006年 / 1卷 / 60-73期
关键词
Buildings - Computer simulation - Condensation - Control system analysis - Control system synthesis - Floors - Flow control - Flow of water - Structural design - Temperature control;
D O I
10.1016/j.buildenv.2005.01.019
中图分类号
学科分类号
摘要
In applying radiant floor cooling, its control system must prevent the floor surface condensation in hot and humid weather conditions. With no additional dehumidification system, only the radiant floor cooling system prevents floor condensation. In this case, the effects of the control of the cooling system on the indoor conditions can be changed because of the thermal inertia of the systems. Also different types of control system can be composed according to the control methods, which can affect the construction cost in the design stage. Therefore, the control methods for the radiant cooling system with respect to floor surface condensation must be studied. Furthermore, because Korean people's lifestyle involves sitting on the floor, it is necessary to evaluate if a floor cooling system will influence the thermal comfort of the occupants. This study intends to clarify the control methods of the radiant floor cooling system and to analyze the control performance and applicability of each control method with regard to the floor surface condensation and comfort by computer simulations and experiments on the control methods of the radiant floor cooling system. The results of computer simulations and experiments show that water temperature control is better than water flow control with respect to temperature fluctuations in controlling room air temperature. To prevent floor surface condensation, the supply water temperature could be manipulated according to the dew point temperature in the most humid room, and in individual rooms, the water flow rate (on/off control) can be controlled. Also, the results of radiant cooling experiments show that the floor surface temperature remained above 21 °C, the temperature difference among surfaces remained below 6 °C, and the vertical air temperature difference remained below 1.9 °C, conforming well to comfort standards. © 2005 Elsevier Ltd. All rights reserved.
引用
收藏
相关论文
共 50 条
  • [41] Applicability of Radiant Heating-Cooling Ceiling Panels in Residential Buildings in Different Climates of Iran
    Moslehi, S.
    Maerefat, M.
    Arababadi, R.
    ICSDEC 2016 - INTEGRATING DATA SCIENCE, CONSTRUCTION AND SUSTAINABILITY, 2016, 145 : 18 - 25
  • [42] Downdraft Assessment of Glass Curtain Wall Buildings with a Radiant Floor Heating System
    Joe, Goosang
    Kim, Dongwoo
    Park, Sanghoon
    Park, Sojeong
    Yeo, Myoungsouk
    Kim, Kwangwoo
    APPLIED SCIENCES-BASEL, 2017, 7 (10):
  • [43] Comparison of the Floor and Infrared Radiant Heating System in Large-Space Buildings
    Jia, Lizhi
    Liu, Junjie
    Xiao, Wu
    Zhang, Haiqiao
    PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 1906 - 1912
  • [44] Application of PCM for radiant heating of residential buildings in Canada towards achieving nearly zero energy buildings
    Hosseini, Mohammadmehdi
    Tasnim, Syeda Humaira
    Mahmud, Shohel
    JOURNAL OF ENERGY STORAGE, 2024, 102
  • [45] Research on Suitable Application Sites of Radiant Cooling System
    Shou, Q.
    He, J.
    2011 2ND INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY ENGINEERING (ICAEE), 2012, 14 : 1002 - 1007
  • [46] Effects of controls and floor construction of radiant floor heating systems for residential application with high variability of solar gains
    Brideau, Sebastien A.
    Beausoleil-Morrison, Ian
    Kummert, Michael
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2020, 26 (04) : 524 - 540
  • [47] Experimental Study on Ceiling Radiant Cooling Panel System with Personal Floor Diffuser
    Ito, Sei
    Kawashima, Minoru
    Arai, Yoshito
    Suzuki, Michiya
    Murakami, Koji
    Nobe, Tatsuo
    ASHRAE TRANSACTIONS 2012, VOL 118, PT 2, 2012, 118 : 330 - 337
  • [48] Evaluating the passive and free cooling application methods of phase change materials in residential buildings: A comparative study
    Alam, Morshed
    Sanjayan, Jay
    Zou, Patrick X. W.
    Ramakrishnan, Sayanthan
    Wilson, John
    ENERGY AND BUILDINGS, 2017, 148 : 238 - 256
  • [49] Developing a collaborative control strategy of a combined radiant floor cooling and ventilation system: A PMV-based model
    Ren, Jing
    Liu, Jiying
    Zhou, Shiyu
    Kim, Moon Keun
    Miao, Jikui
    JOURNAL OF BUILDING ENGINEERING, 2022, 54
  • [50] A Simplified Thermal Comfort Calculation Method of Radiant Floor Cooling Technology for Office Buildings in Northern China
    Wang, Xiaolong
    Mu, Tian
    Zhang, Lili
    Zhang, Wenke
    Zhang, Linhua
    BUILDINGS, 2022, 12 (04)