Application of the control methods for radiant floor cooling system in residential buildings

被引:82
|
作者
Department of Architecture, College of Engineering, Seoul National University, Seoul, Korea, Republic of [1 ]
不详 [2 ]
不详 [3 ]
机构
来源
Build. Environ. | 2006年 / 1卷 / 60-73期
关键词
Buildings - Computer simulation - Condensation - Control system analysis - Control system synthesis - Floors - Flow control - Flow of water - Structural design - Temperature control;
D O I
10.1016/j.buildenv.2005.01.019
中图分类号
学科分类号
摘要
In applying radiant floor cooling, its control system must prevent the floor surface condensation in hot and humid weather conditions. With no additional dehumidification system, only the radiant floor cooling system prevents floor condensation. In this case, the effects of the control of the cooling system on the indoor conditions can be changed because of the thermal inertia of the systems. Also different types of control system can be composed according to the control methods, which can affect the construction cost in the design stage. Therefore, the control methods for the radiant cooling system with respect to floor surface condensation must be studied. Furthermore, because Korean people's lifestyle involves sitting on the floor, it is necessary to evaluate if a floor cooling system will influence the thermal comfort of the occupants. This study intends to clarify the control methods of the radiant floor cooling system and to analyze the control performance and applicability of each control method with regard to the floor surface condensation and comfort by computer simulations and experiments on the control methods of the radiant floor cooling system. The results of computer simulations and experiments show that water temperature control is better than water flow control with respect to temperature fluctuations in controlling room air temperature. To prevent floor surface condensation, the supply water temperature could be manipulated according to the dew point temperature in the most humid room, and in individual rooms, the water flow rate (on/off control) can be controlled. Also, the results of radiant cooling experiments show that the floor surface temperature remained above 21 °C, the temperature difference among surfaces remained below 6 °C, and the vertical air temperature difference remained below 1.9 °C, conforming well to comfort standards. © 2005 Elsevier Ltd. All rights reserved.
引用
收藏
相关论文
共 50 条
  • [31] Experimental investigation on model predictive control of radiant floor cooling combined with underfloor ventilation system
    Zhang, Dongliang
    Cai, Ning
    Cui, Xiaobo
    Xia, Xueying
    Shi, Jianzhong
    Huang, Xiaoqing
    ENERGY, 2019, 176 : 23 - 33
  • [32] Possibilities and limitations of radiant floor cooling
    Olesen, BW
    ASHRAE TRANSACTIONS 1997, VOL 103, PT I, 1997, 103 : 42 - 48
  • [33] Radiant Conditioning Retrofitting for Residential Buildings
    Do, Hung Q.
    Luther, Mark B.
    Amirkhani, Mehdi
    Wang, Zheng
    Martek, Igor
    ENERGIES, 2022, 15 (02)
  • [34] Nationwide Energy Saving Analysis of Radiant Floor System for Commercial Buildings
    Li, Yanfei
    Niu, Fuxin
    Qian, Defeng
    O'Neill, Zheng
    2018 ASHRAE ANNUAL CONFERENCE, 2018,
  • [35] Improving a Heating Supply Water Temperature Control for Radiant Floor Heating Systems in Korean High-Rise Residential Buildings
    Yeom, Gyuhwan
    Jung, Dong Eun
    Do, Sung Lok
    SUSTAINABILITY, 2019, 11 (14)
  • [36] Performance evaluation of a radiant floor cooling system integrated with dehumidified ventilation
    Song, Doosam
    Kim, Taeyeon
    Song, Suwon
    Hwang, Suckho
    Leigh, Seung-Bok
    APPLIED THERMAL ENGINEERING, 2008, 28 (11-12) : 1299 - 1311
  • [37] Analysis of feasibility of floor radiant cooling system combined with displacement ventilation
    Li, DY
    Ren, YL
    Wang, ZJ
    2ND ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, PROCEEDINGS: NEW CONTRIBUTION TO ASIAN SUSTAINABLE DEVELOPMENT, 2004, : 634 - 637
  • [38] EXPERIMENTAL STUDY ON THERMAL PERFORMANCE OF THE RADIANT FLOOR COOLING SYSTEM IN BEIJING
    Wu, Pin
    Chen, Chao
    Lin, Jie
    Li, Qingqing
    Li, Zhuo
    Zhang, Ye
    Quan, Zhenhua
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 2139 - 2146
  • [39] Thermal performance of radiant floor cooling with phase change material for energy-efficient buildings
    Kamil, Qusay
    Abd, Najim
    OPEN ENGINEERING, 2024, 14 (01):
  • [40] Energy Saving Potential of Radiant Floor Heating Assisted by an Air Source Heat Pump in Residential Buildings
    Hwang, Yu-Jin
    Jeong, Jae-Weon
    ENERGIES, 2021, 14 (05)