Study on the frequency-scan quadrupole ion trap mass spectrometry

被引:0
|
作者
Cui, Fenping [1 ]
Pei, Shijin [2 ]
Liu, Yanli [1 ]
Chen, Yulin [1 ]
机构
[1] College of Math and Physics, Nanjing University of Information Science and Technology, Nanjing, Jiangsu 210044, China
[2] College of Technology and Engineering, Lanzhou University of Science and Technology, Lanzhou, Gansu 730050, China
来源
Guangxue Xuebao/Acta Optica Sinica | 2009年 / 29卷 / SUPPL.期
关键词
Mass spectrometry;
D O I
10.3788/AOS200929S1.223
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Charge detection quadrupole ion trap (QIT) mass spectrometry (MS) is an effective technique for high-speed mass analysis of micron-sized particles such as biological cells and aerosols. In this technique, the trap can be operated by scanning the frequency of the ac field under a low-vacuum condition. This paper describes a calibration method which involves determination of the points of ejection (qeject) of the individual particles to be analyzed how the ejection points vary with the pressure of buffer gas. Using NIST polystyrene size as the test samples, a mean ejection point of qeject = 0.952 is attained at the trap driving voltage amplitude of 1617 V, with He buffer gas pressure of 5.33 Pa, and a frequency scan rate of 70 Hz/s over the scan range of 450-100 Hz. The mean value (0.947) of qeject is measured without the buffer gas. The result indicates the buffer gas has an effect on the ejection point of particle in the trap.
引用
收藏
页码:223 / 225
相关论文
共 50 条
  • [41] Identifying hypertension biomarkers by triple quadrupole linear ion trap mass triple spectrometry
    Hunter, C
    Basa, L
    LC GC EUROPE, 2004, : 27 - 28
  • [42] Optimization of a quadrupole ion storage trap as a source for time-of-flight mass spectrometry
    Dangi, Beni B.
    Ervin, Kent M.
    JOURNAL OF MASS SPECTROMETRY, 2012, 47 (01): : 41 - 48
  • [43] ENHANCED MASS RESOLUTION IN A QUADRUPOLE ION TRAP
    LONDRY, FA
    WELLS, GJ
    MARCH, RE
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (01) : 43 - 45
  • [44] Multiple precursor ion monitoring - a new scan strategy on hybrid quadrupole/linear ion trap mass spectrometers?
    Rogalski, JC
    Lin, SJ
    Kast, J
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (06) : 739 - 741
  • [45] Effects of fragile ions on mass resolution and on isolation for tandem mass spectrometry in the quadrupole ion trap mass spectrometer
    McClellan, JE
    Murphy, JP
    Mulholland, JJ
    Yost, RA
    ANALYTICAL CHEMISTRY, 2002, 74 (02) : 402 - 412
  • [46] A dual quadrupole ion trap mass spectrometer
    Zerega, Y
    Perrier, P
    Carette, M
    Brincourt, G
    Nguema, T
    Andre, J
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1999, 191 : 59 - 68
  • [47] Ion-molecule reactions in quadrupole ion trap mass spectrometry: implications for lightweight gas analysis
    Ottens, AK
    Arkin, CR
    Griffin, TP
    Palmer, PT
    Harrison, WW
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2005, 243 (01) : 31 - 39
  • [49] THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY WITH A QUADRUPOLE ION TRAP MASS-SPECTROMETER
    KAISER, RE
    WILLIAMS, JD
    LAMMERT, SA
    COOKS, RG
    ZAKETT, D
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 562 (1-2): : 3 - 11
  • [50] Ion energy in quadrupole mass spectrometry
    Baranov, V
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2004, 15 (01) : 48 - 54