Faulty line selection in non-solid earthed network based on zero sequence frequency characteristic of transmission line

被引:0
|
作者
School of Electrical Engineering, Wuhan University, Wuhan 430072, China [1 ]
不详 [2 ]
机构
来源
Dianli Zidonghua Shebei Electr. Power Autom. Equip. | 2006年 / 4卷 / 59-62期
关键词
Capacitors - Electric lines - Frequencies - Transients - Wavelet transforms;
D O I
暂无
中图分类号
学科分类号
摘要
According to the frequency characteristic of an even transmission line, when the frequency is lower than fm, the input impedance of an unloaded even transmission line is capacitive, and the line maybe modeled as a capacitor. The healthy line is unloaded for zero-sequence component when a single-phase fault occurs in a non-solid earthed network. The zero-sequence angle -frequency characteristic of the lines are studied based on it and the characteristics of transient zero-sequence current in different frequency bands when a single-phase fault occurs in a non-solid earthed network are found. In SFB (Selected Frequency Band), the polarity of transient zero-sequence current in faulty line is opposite to that in healthy ones. The wavelet packet is used to decompose transient zero-sequence current and the coefficients represent the polarity of the current. Comparison of coefficient signs can find out the faulty line. The EMTDC simulations indicate that the method can find out the faulty line correctly and prove that the analysis of the angle-frequency characteristic of zero impedance of the line is correct.
引用
收藏
相关论文
共 50 条
  • [1] Selecting the Faulty Line through Correlation of Zero-Sequence Currents in Non-solid Earthed Network
    Xing Ya-hui
    Lv Yan-ping
    Zhao Jun
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 1949 - 1952
  • [2] Faulty line selection with correlativity of zero sequence current in non-solid-earthed network
    Xing, Yahui
    Dianli Zidonghua Shebei / Electric Power Automation Equipment, 2008, 28 (09): : 64 - 67
  • [3] Fault line selection device for non-solid earthed network based on transient zero-sequence current features
    Xu, Jingdong
    Zhang, Baohui
    You, Min
    Yan, Haishan
    Liu, Haifeng
    Yang, Lu
    Dianli Zidonghua Shebei / Electric Power Automation Equipment, 2009, 29 (04): : 101 - 105
  • [4] An Improved Fault Line Selection Method Based on Traveling waves in Non-solid Earthed Network
    Zhang, Qing
    Zhao, Yong
    Han, Xianfang
    Sun, Yingtao
    2017 CHINESE AUTOMATION CONGRESS (CAC), 2017, : 4553 - 4557
  • [5] Faulty line selection based on transient wavelet energy for non-solid-earthed network
    Wu, Lepeng
    Huang, Chun
    Lin, Dabin
    Zhu, Zhijun
    Jiang, Hongtao
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2013, 33 (05): : 70 - 75
  • [6] A method of fault line selection in resonant earthed system based on zero sequence impedance characteristic of lines
    Tang, Tao
    Huang, Chun
    Jiang, Yaqun
    Luo, Xunhua
    Liu, Penghui
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2016, 31 (20): : 192 - 201
  • [7] A New Adaptive Fault Line Selection Method Based on Multi-scale Wavelet Packet Decomposition in Non-solid Earthed Network
    Liang Zhenglin
    Zhang Feng
    Liang Jun
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [8] Faulty line detection based on instantaneous zero-sequence power for resonant earthed system
    Faculty of Electric Power Engineering, Kunming University of Science and Technology, Kunming 650500, China
    Li, B. (kmlb@vip.sina.com), 2013, Electric Power Automation Equipment Press (33):
  • [9] Principle of directional earth fault protection using zero sequence transients in non-solid earthed network
    Xue, Yong-Duan
    Xu, Bing-Yin
    Feng, Zu-Ren
    Li, Tian-You
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2003, 23 (07): : 51 - 56
  • [10] Faulty line selection based on time-frequency characteristics of transient zero-sequence current
    Shu, Hongchun
    Zhu, Mengmeng
    Huang, Wenzhen
    Duan, Ruimin
    Dong, Jun
    Gao, Li
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2013, 33 (09): : 1 - 6