Comparison of Nondestructive Methods for Detecting Reinforcing Bar Placement

被引:0
|
作者
Burney, David C. [1 ]
Kurtis, Kimberly E. [2 ]
Jacobs, Laurence J. [3 ]
Sherman, Ryan J. [4 ]
机构
[1] Lewis & Clark Coll, Portland, OR 97219 USA
[2] Georgia Inst Technol, Sch Mat Sci & Engn, Civil & Environm Engn, Atlanta, GA USA
[3] Georgia Inst Technol, Civil & Environm & Mech Engn, Atlanta, GA USA
[4] Georgia Inst Technol, Civil & Environm Engn, Atlanta, GA USA
关键词
cover; dowel; eddy current; epoxy-coated; galvanized; ground-penetrating radar (GPR); quality assurance; stainless steel; CONCRETE;
D O I
10.14359/51742260
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Despite improvements in nondestructive testing (NDT) technologies, the quality assurance of concrete reinforcing bar placement is still primarily conducted with conventional methodologies, which can be time-consuming, ineffective, and damaging to the concrete components. This study investigated the performance of two commercially available cover meters and one groundpenetrating radar (GPR) device. A cover meter was found to have the greatest accuracy for depths smaller than 3.19 in. (81.0 mm), while the GPR performed better for greater depths. The effect of reinforcing bar depth, diameter, and type; neighboring reinforcing bars; and concrete conditioning on the performance of the devices was quantified. The use of epoxy-coated reinforcing bar, galvanized reinforcing bar, and stainless-steel reinforcing bar were found to have a negligible effect on cover meter accuracy. A model was developed to predict the precision of the GPR post-measurement analysis given a depth and concrete dielectric constant.
引用
收藏
页码:27 / 40
页数:14
相关论文
共 50 条
  • [1] A comparison of nondestructive evaluation methods for bridge deck assessment
    Scott, M
    Rezaizadeh, A
    Delahaza, A
    Santos, CG
    Moore, M
    Graybeal, B
    Washer, G
    NDT & E INTERNATIONAL, 2003, 36 (04) : 245 - 255
  • [2] Probabilistic calibration for development length models of deformed reinforcing bar
    Yu, Bo
    Tang, Ruikai
    Li, Bing
    ENGINEERING STRUCTURES, 2019, 182 : 279 - 289
  • [3] Effects of the corrosion of main bar and stirrups on the bond behavior of reinforcing steel bar
    Lin, Hongwei
    Zhao, Yuxi
    Yang, Jia-Qi
    Feng, Peng
    Ozbolt, Josko
    Ye, Hailong
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 225 : 13 - 28
  • [4] Corrosion Evaluation by Estimating the Surface Resistivity of Reinforcing Bar
    Lim, Young-Chul
    Noguchi, Takafumi
    Shin, SungWoo
    JOURNAL OF ADVANCED CONCRETE TECHNOLOGY, 2010, 8 (02) : 113 - 119
  • [5] Study on metal hardness nondestructive detecting instrument
    Lu, JG
    Sun, YS
    ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, : 4905 - 4908
  • [6] Research on compressive strength deterioration of concrete by corrosion of reinforcing bar
    Zhang, XD
    Peng, XN
    Wei, SY
    Zhou, L
    PROCEEDINGS OF THE EIGHTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING FOR YOUNG EXPERTS, VOLS 1 AND 2, 2004, : 1145 - 1151
  • [7] Variability of chemical analysis of reinforcing bar produced in Saudi Arabia
    Salman, A.
    Djavanroodi, F.
    INTERNATIONAL CONFERENCE ON MATERIALS ENGINEERING AND APPLICATIONS, 2018, 348
  • [8] Elevated temperature material properties of stainless steel reinforcing bar
    Gardner, L.
    Bu, Y.
    Francis, P.
    Baddoo, N. R.
    Cashell, K. A.
    McCann, F.
    CONSTRUCTION AND BUILDING MATERIALS, 2016, 114 : 977 - 997
  • [9] Accelerated testing for concrete reinforcing bar corrosion protection systems
    Darwin, D
    Balma, J
    Locke, CE
    Nguyen, TV
    LONG TERM DURABILITY OF STRUCTURAL MATERIALS - DURABILITY 2000, 2001, : 97 - 108
  • [10] Corrosion Evaluation of Steel Reinforcing Bar Using Electromagnetic Method
    He, D. F.
    Takaya, S.
    Tsutsumi, N.
    Tsuchiya, K.
    2019 PHOTONICS & ELECTROMAGNETICS RESEARCH SYMPOSIUM - SPRING (PIERS-SPRING), 2019, : 690 - 693