Verification on collapse behaviors of high-rise buildings under fire using numerical approach

被引:0
作者
Isobe D. [1 ]
Le T.T.T. [1 ]
机构
[1] Dept. of Engineering Mechanics and Energy, Univ. of Tsukuba
来源
Journal of Structural and Construction Engineering | 2011年 / 76卷 / 667期
关键词
ASI-Gauss technique; Collapse behavior; Collapse initiation time; High-rise buildings; Outrigger truss system; Redundant strength;
D O I
10.3130/aijs.76.1659
中图分类号
学科分类号
摘要
Fire-induced collapse behaviors of a high-rise building with an outrigger truss system were verified using the ASI-Gauss technique. The effects of fire patterns and structural parameters on the redundant strengths were surveyed by observing the collapse initiation time: the duration from the beginning of the fire until collapse initiation. From the numerical results, it is confirmed that collapse initiation times are significantly affected by the member joint strengths if the axial force ratio is small on the condition that the fire pattern is nearly symmetrical, and the load paths to and from the outrigger truss system are sufficiently protected.
引用
收藏
页码:1659 / 1664
页数:5
相关论文
共 4 条
[1]  
World Trade Center Building Performance Study: Data Collection, Preliminary Observation and Recommendations, (2002)
[2]  
Federal Building and Fire Safety Investigation of the World Trade Center Disaster: Final Report on the Collapse of the World Trade Center Towers, (2005)
[3]  
Toi Y., Isobe D., Adaptively shifted integration technique for finite element collapse analysis of framed structures, Int. J. Numer. Methods Eng., 36, pp. 2323-2339, (1993)
[4]  
Bathe K.J., Finite Element Procedures, (1996)