Optimizing Industrial Solid-Phase Peptide Synthesis: Integration of Raman Spectroscopy as Process Analytical Technology

被引:1
作者
Stager, Michael A. [1 ]
Peroza, Carlos [1 ]
Villaumie, Julien [2 ]
Bilham, Christopher [1 ]
Desmond, Cameron [1 ]
Harris, Marcus [1 ]
Sambasivan, Ramya [1 ]
Rowe, Gary [1 ]
Chen, Lin [1 ]
Tucker, Charles [1 ]
机构
[1] Corden Pharm Colorado, 2075 55th St, Boulder, CO 80301 USA
[2] Corden Pharm Int LLC, CH-4051 BASEL, Switzerland
关键词
Solid-Phase PeptideSynthesis (SPPS); Process AnalyticalTechnology (PAT); Raman Spectroscopy; IN-LINE; TOOL;
D O I
10.1021/acs.oprd.4c00432
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Peptide therapeutics have exploded in popularity in recent years, motivating the need for advanced manufacturing methods which can be applied across the solid-phase peptide synthesis (SPPS) process. The Food and Drug Administration's Process Analytical Technology (PAT) initiative offers a platform to implement advanced methods to improve the efficiency and understanding of pharmaceutical manufacturing processes and shows great promise in application toward industrial SPPS. In this work, Raman spectroscopy was used as the main PAT tool to implement methods for on-line and real-time monitoring of the entire SPPS process, from Fmoc removal, to coupling, and through the extensive solvent-washing steps. Raman spectroscopy is a rapid, specific, and nondestructive technique that can provide rich real-time information for SPPS processes and can be used to improve efficiency in solvent use and save process time. Specifically, this work reports on the development of PAT methods for monitoring of amino acid coupling during the coupling stage and residual piperidine concentration during the post-deprotection washing stage of SPPS, to help reduce solvent use and better understand the coupling reaction and its time frame. We show a significant reduction in solvent use is possible by employing Raman spectroscopy along with a partial least squares model to predict the piperidine concentration in real time during continuous wash. In addition, Raman spectroscopy offers a greater understanding of coupling reaction kinetics during SPPS, which could lead to significant improvements in total SPPS process time.
引用
收藏
页码:4501 / 4512
页数:12
相关论文
共 38 条
[1]   2022 FDA TIDES (Peptides and Oligonucleotides) Harvest [J].
Al Musaimi, Othman ;
Al Shaer, Danah ;
Albericio, Fernando ;
de la Torre, Beatriz G. .
PHARMACEUTICALS, 2023, 16 (03)
[2]   PAT-based batch statistical process control of a manufacturing process for a pharmaceutical ointment [J].
Bostijn, N. ;
Dhondt, W. ;
Vervaet, C. ;
De Beer, T. .
EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2019, 136
[3]   Green Solid-Phase Peptide Synthesis: Oxyma-Triggered Spectrophotometric Monitoring of Residual Piperidine [J].
Broman, Soren Lindbaek ;
Rosenberg, Martin ;
Wojcik, Felix ;
Hansen, Anders Holm ;
Egelund, Peter Hammer Guldager ;
Malmstrom, Joan ;
Pedersen, Daniel Sejer .
ORGANIC PROCESS RESEARCH & DEVELOPMENT, 2024, 28 (03) :666-673
[4]   Applications of Raman Spectroscopy in Biopharmaceutical Manufacturing: A Short Review [J].
Buckley, Kevin ;
Ryder, Alan G. .
APPLIED SPECTROSCOPY, 2017, 71 (06) :1085-1116
[5]   Raman database of amino acids solutions: a critical study of Extended Multiplicative Signal Correction [J].
Candeloro, Patrizio ;
Grande, Elisabetta ;
Raimondo, Raffaella ;
Di Mascolo, Daniele ;
Gentile, Francesco ;
Coluccio, Maria Laura ;
Perozziello, Gerardo ;
Malara, Natalia ;
Francardi, Marco ;
Di Fabrizio, Enzo .
ANALYST, 2013, 138 (24) :7331-7340
[6]   Raman spectroscopy as a process analytical technology (PAT) tool for the in-line monitoring and understanding of a powder blending process [J].
De Beer, T. R. M. ;
Bodson, C. ;
Dejaegher, B. ;
Walczak, B. ;
Vercruysse, P. ;
Burggraeve, A. ;
Lemos, A. ;
Delattre, L. ;
Heyden, Y. Vander ;
Remon, J. P. ;
Vervaete, C. ;
Baeyens, W. R. G. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 48 (03) :772-779
[7]   Implementation of a process analytical technology system in a freeze-drying process using Raman Spectroscopy for in-line process monitoring [J].
De Beer, T. R. M. ;
Alleso, M. ;
Goethals, F. ;
Coppens, A. ;
Heyden, Y. Vander ;
De Diego, H. Lopez ;
Rantanen, J. ;
Verpoort, F. ;
Vervaet, C. ;
Remon, J. P. ;
Baeyens, W. R. G. .
ANALYTICAL CHEMISTRY, 2007, 79 (21) :7992-8003
[8]   In-Line and Real-Time Process Monitoring of a Freeze Drying Process Using Raman and NIR Spectroscopy as Complementary Process Analytical Technology (PAT) Tools [J].
De Beer, T. R. M. ;
Vercruysse, P. ;
Burggraeve, A. ;
Quinten, T. ;
Ouyang, J. ;
Zhang, X. ;
Vervaet, C. ;
Remon, J. P. ;
Baeyens, W. R. G. .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2009, 98 (09) :3430-3446
[9]   Refractive Index: The Ultimate Tool for Real-Time Monitoring of Solid-Phase Peptide Synthesis. Greening the Process [J].
de la Torre, Beatriz G. ;
Ramkisson, Shaveer ;
Albericio, Fernando ;
Lopez, John .
ORGANIC PROCESS RESEARCH & DEVELOPMENT, 2021, 25 (04) :1047-1053
[10]   Fmoc-Removal with Pyrrolidine Expands the Available Solvent Space in Green Solid-Phase Peptide Synthesis [J].
Egelund, Peter H. G. ;
Jadhav, Sandip ;
Martin, Vincent ;
Castro, Henrik Johansson ;
Richner, Franziska ;
Le Quement, Sebastian Thordal ;
Dettner, Frank ;
Lechner, Carolin ;
Schoenleber, Ralph ;
Pedersen, Daniel Sejer .
ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2021, 9 (42) :14202-14215