Compact high-bandwidth single-beam optically-pumped magnetometer for biomagnetic measurement

被引:0
|
作者
Wu, Tianbo [1 ,2 ]
Xiao, Wei [1 ,2 ,3 ]
Peng, Xiang [1 ,2 ]
Wu, Teng [1 ,2 ]
Guo, Hong [1 ,2 ]
机构
[1] Peking Univ, Sch Elect, State Key Lab Adv Opt Commun Syst & Networks, Beijing 100871, Peoples R China
[2] Peking Univ, Ctr Quantum Informat Technol, Beijing 100871, Peoples R China
[3] Beijing Inst Technol, Adv Res Inst Multidisciplinary Sci, MIIT Key Lab Complex Field Intelligent Sensing, Beijing 100081, Peoples R China
来源
BIOMEDICAL OPTICS EXPRESS | 2025年 / 16卷 / 01期
基金
中国国家自然科学基金;
关键词
ATOMIC MAGNETOMETER; SYSTEM; MAGNETOENCEPHALOGRAPHY; MAGNETOCARDIOGRAPHY; PERFORMANCE; GENERATION;
D O I
10.1364/BOE.545624
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Optically-pumped magnetometer (OPM) has been of increasing interest for biomagnetic measurements due to its low cost and portability compared with superconducting quantum interference devices (SQUID). Miniaturized spin-exchange-relaxation-free (SERF) OPMs typically have limited bandwidth (less than a few hundred Hertz), making it difficult to measure high-frequency biomagnetic signals such as the magnetocardiography (MCG) signal of the mouse. Existing experiments mainly use SQUID systems to measure the signal. In this paper, we introduce a prototype miniaturized single-beam SERF magnetometer with a bandwidth of 1 kHz. Instead of operating the OPM in a closed-loop mode to improve the bandwidth of the OPM, which usually has a poorer performance in high-frequency range, we use the power-broadening effects to shorten the spin relaxation time and thus a faster response to the magnetic fields to be measured. Combined with light power stabilizations to improve both the sensitivity and stability, our magnetometer has a low noise floor of 30 fT / Hz1/2, which has been successfully adopted to measure the MCG signal of the mouse. (c) 2024 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement
引用
收藏
页码:235 / 244
页数:10
相关论文
共 35 条
  • [1] Light-noise suppression method for the single-beam optically-pumped magnetometer arrays
    Suo, Yuchen
    Song, Xinda
    Wu, Zhendong
    Yuan, Ziqi
    Jia, Le
    Long, Tengyue
    OPTICS EXPRESS, 2023, 31 (13) : 21280 - 21295
  • [2] Characterization of noise sources in a microfabricated single-beam zero-field optically-pumped magnetometer
    Krzyzewski, S. P.
    Perry, A. R.
    Gerginov, V.
    Knappe, S.
    JOURNAL OF APPLIED PHYSICS, 2019, 126 (04)
  • [3] High-sensitivity operation of single-beam optically pumped magnetometer in a kHz frequency range
    Savukov, I.
    Kim, Y. J.
    Shah, V.
    Boshier, M. G.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2017, 28 (03)
  • [4] Suppression of modulation-magnetic-fields crosstalk for single-beam optically-pumped magnetometers
    Suo, Yuchen
    Song, Xinda
    Jiang, Liwei
    Jia, Le
    Long, Tengyue
    Wu, Zhendong
    MEASUREMENT, 2023, 217
  • [5] Triaxial closed-loop measurement based on a single-beam zero-field optically pumped magnetometer
    Wang, Kun
    Zhang, Kaixuan
    Zhou, Binquan
    Lu, Fei
    Zhang, Shaowen
    Yan, Yeguang
    Wang, Weiyi
    Lu, Jixi
    FRONTIERS IN PHYSICS, 2022, 10
  • [6] Vector magnetometry employing a rotating RF field in a single-beam optically pumped magnetometer
    Zou, Yuntian
    Jiang, Liwei
    Bai, Huijing
    Liu, Jiali
    Fang, Chi
    Zhu, Jun
    Shao, Qi
    Xu, Jinghong
    Zhou, Xiangyang
    Quan, Wei
    SENSORS AND ACTUATORS A-PHYSICAL, 2024, 379
  • [7] A high sensitivity and strong stability miniaturized optically-pumped magnetometer
    Wu, Zinan
    Zhang, Yang
    He, Mengyang
    Ren, Bokang
    Yue, Huimin
    Ou, Zhonghua
    Zhou, Xiaojun
    Liu, Yong
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2022, 61 (07)
  • [8] Single-Beam Double-Pass Miniaturized Atomic Magnetometer for Biomagnetic Imaging Systems
    Li, Xiaojie
    Guo, Zhihao
    Yang, Rui
    Feng, Yanying
    IEEE SENSORS JOURNAL, 2023, 23 (12) : 12433 - 12440
  • [9] Triaxial precise magnetic field compensation of a zero-field optically pumped magnetometer based on a single-beam configuration
    Zhang, Shaowen
    Zhang, Kaixuan
    Zhou, Ying
    Ye, Mao
    Lu, Jixi
    OPTICS EXPRESS, 2022, 30 (14): : 24579 - 24588
  • [10] COMPACT, HIGH-EFFICIENCY, OPTICALLY-PUMPED NH3 LASER
    WALKER, B
    CHANTRY, GW
    MOSS, DG
    OPTICS COMMUNICATIONS, 1977, 23 (01) : 8 - 10