Forced Oscillation Source Location of Doubly-fed Wind Turbine Based on Transient Energy Flow

被引:0
|
作者
Cao N. [1 ]
Zhao X. [1 ]
Yu Q. [1 ]
机构
[1] College of Electrical Engineering and Automation, Shandong University of Science and Technology, Qingdao
来源
Zhao, Xu (2465740593@qq.com) | 1600年 / Automation of Electric Power Systems Press卷 / 44期
关键词
Doubly-fed wind turbine; Energy flow power; Forced oscillation source; Transient energy flow;
D O I
10.7500/AEPS20190527005
中图分类号
学科分类号
摘要
Transient energy flow method is a new method for locating oscillation sources. Firstly, according to the calculation formula of transient energy flow, combined with the shafting model, the grid-side converter model of doubly-fed wind turbine and the third-order simplified model of doubly-fed induction motor, the transient energy flow for doubly-fed wind turbine is deduced and the energy flow power is defined as an index of the energy flow direction. Secondly, the frequency characteristics of the doubly-fed wind turbine are analyzed after the forced sources are added. Finally, based on the PSCAD/EMTDC electromagnetic transient simulation platform, a single-machine infinite system with forced oscillation sources and a grid connection system of several wind turbines via series compensated line are built for time-domain simulation. Transient energy flow and energy flow power are calculated using the collected data. The validity of the transient energy flow method for locating the forced oscillation sources of doubly-fed wind turbines is verified. © 2020 Automation of Electric Power Systems Press.
引用
收藏
页码:103 / 110
页数:7
相关论文
共 23 条
  • [1] Wang W., Zhang C., He G., Et al., Overview of research on subsynchronous oscillations in large-scale wind farm integrated system, Power System Technology, 41, 4, pp. 1050-1059, (2017)
  • [2] Wang L., Xie X., Jiang Q., Et al., Analysis and mitigation of SSR problems in large-scale wind farms with doubly-fed wind turbines, Automation of Electric Power Systems, 38, 22, pp. 26-31, (2014)
  • [3] Dong X., Tian X., Zhang Y., Et al., Practical SSR incidence and influencing factor analysis of DFIG-based series-compensated transmission system in Guyuan farms, High Voltage Engineering, 43, 1, pp. 321-328, (2017)
  • [4] Research on sub-synchronous oscillation analysis and suppression strategy for large-scale series-compensated DFIG-based wind farm, (2018)
  • [5] Dong X., Xie X., Yang Y., Et al., Impacting factors and stable area analysis of subsynchronous resonance in DFIG based wind farms connected to series-compensated power system, Power System Technology, 39, 1, pp. 189-193, (2015)
  • [6] Cao X., Liu T., Li X., Disturbance source location for forced power oscillations by wind turbines, Electric Machines and Control, 18, 10, pp. 81-86, (2014)
  • [7] Chen L., Min Y., Hu W., Low frequency oscillation analysis and oscillation source location based on oscillation energy: Part one mathematical foundation and energy flow computation, Automation of Electric Power Systems, 36, 3, pp. 22-27, (2012)
  • [8] Chen L., Chen Y., Min Y., Et al., Low frequency oscillation analysis and oscillation source location based on oscillation energy: Part two method for oscillation source location and case studies, Automation of Electric Power Systems, 36, 4, pp. 1-5, (2012)
  • [9] Li W., Guo J., Li Y., Et al., Power system oscillation analysis and oscillation source location based on WAMS: Part 1 method of cutset energy, Proceedings of the CSEE, 33, 25, pp. 41-46, (2013)
  • [10] Li W., Li Y., Zhou X., Et al., Power system oscillation analysis and oscillation source location based on WAMS: Part 2 method of torques decomposition, Proceedings of the CSEE, 33, 25, pp. 47-53, (2013)