Detection of localized corrosion in ferromagnetic metal pipe under insulation with pulsed eddy current testing

被引:0
作者
机构
[1] Key Laboratory of Nondestructive Testing, Ministry of Education, Nanchang Hangkong University
来源
Fu, Y. (fuyuewen@126.com) | 2013年 / Editorial Board of Journal of Basic Science and卷 / 21期
关键词
Corrosion; Finite element; Insulation; Pipe; Pulsed eddy current;
D O I
10.3969/j.issn.1005-0930.2013.04.020
中图分类号
学科分类号
摘要
Probe design was studied by simulation and experiments to improve detection sensitivity of localized corrosion in ferromagnetic metal pipe under insulation with pulsed eddy current (PEC) non-destructive testing. A reversely-connected dual coil was used as excitation source to produce a focused and intense magnetic field without the need of large current in the coil. Finite element method was used to simulate and compare the distribution of magnetic field and eddy current of single coil excitation and dual coil excitation, and a series of experiments were then performed. The experimental results agreed well with the simulation and showed that a much higher sensitivity was achieved using reversely-connected dual coil as excitation than using single coil excitation in the localized corrosion detection of ferromagnetic metal pipe under insulation with PEC testing. This research provides reference for probe design in the localized corrosion detection in metal pipe under insulation with PEC method.
引用
收藏
页码:786 / 795
页数:9
相关论文
共 50 条
[31]   Excitation current waveform for eddy current testing on the thickness of ferromagnetic plates [J].
Chen, Xingle ;
Lei, Yinzhao .
NDT & E INTERNATIONAL, 2014, 66 :28-33
[32]   Detection of circumferential cracks in heat exchanger tubes using pulsed eddy current testing [J].
Yu, Zhaohu ;
Fu, Yuewen ;
Jiang, Lifan ;
Yang, Fan .
NDT & E INTERNATIONAL, 2021, 121
[33]   Reduction of lift-off effect in pulsed eddy current testing for surface hardness classification of ferromagnetic steel [J].
Duan, Zhaoqi ;
Kang, Yihua ;
Chen, Yanting ;
Wan, Zifu ;
Wang, Shenghan .
MEASUREMENT, 2022, 205
[34]   Analysis of a Pulsed Eddy Current Testing Method for Ferromagnetic Pipeline Wall Thickness Determination Considering Minor Hysteresis [J].
Xin, Wei ;
Lei, Yin-Zhao .
ELECTROMAGNETIC NONDESTRUCTIVE EVALUATION (XVIII), 2015, 40 :117-124
[35]   Time-to-peak of time derivative signals of pulsed eddy current testing for evaluating the thickness of ferromagnetic samples [J].
Wen, Dongdong ;
Wang, Shuchen ;
Zhang, Lei ;
Zhang, Jianhua .
INSIGHT, 2021, 63 (02) :88-94
[36]   Characteristics of Focusing Probe in Pulsed Eddy Current Detection of Water-Wall Tube Corrosion [J].
Tao, Aijun ;
Yang, Fan ;
Fu, Yuewen ;
Huang, Wenfeng ;
Xing, Renfei ;
Tang, Chenhuai ;
Cao, Aisong .
Zhendong Ceshi Yu Zhenduan/Journal of Vibration, Measurement and Diagnosis, 2025, 45 (02) :367-375and416
[37]   Steel Corrosion Characterization Using Pulsed Eddy Current Systems [J].
He, Yunze ;
Tian, Guiyun ;
Zhang, Hong ;
Alamin, Mohammed ;
Simm, Anthony ;
Jackson, Paul .
IEEE SENSORS JOURNAL, 2012, 12 (06) :2113-2120
[38]   Pulsed Eddy Current Response to General Corrosion in Concrete Rebar [J].
Eddy, Ian ;
Underhill, P. R. ;
Morelli, J. ;
Krause, T. W. .
JOURNAL OF NONDESTRUCTIVE EVALUATION, DIAGNOSTICS AND PROGNOSTICS OF ENGINEERING SYSTEMS, 2020, 3 (04)
[39]   Factors Affecting Spatial Resolution in Pulsed Eddy Current Inspection of Pipe [J].
Fu, Y. ;
Underhill, P. R. ;
Krause, T. W. .
JOURNAL OF NONDESTRUCTIVE EVALUATION, 2020, 39 (02)
[40]   Factors Affecting Spatial Resolution in Pulsed Eddy Current Inspection of Pipe [J].
Y. Fu ;
P. R. Underhill ;
T. W. Krause .
Journal of Nondestructive Evaluation, 2020, 39