Spray dust control measures of tunnel blasting dust based on CFD dust-droplet coupling model and orthogonal test

被引:3
作者
Chen, Zheng [1 ]
Zhao, Shulei [1 ]
Dong, Chen [2 ]
Wang, Shuaishuai [3 ]
Guo, Yabin [3 ]
Gao, Xuan [3 ]
Sun, Bing [4 ]
Chen, Wengan [4 ]
Guo, Chun [1 ]
机构
[1] Southwest Jiaotong Univ, Coll Civil Engn, Key Lab Transportat Tunnel Engn, MOE, Chengdu, Peoples R China
[2] Southwest Jiaotong Univ, Sch Transportat & Logist, Chengdu, Peoples R China
[3] CCCC Second Highway Engn Co Ltd, Res & Dev Ctr Construct Technol Long Bridge & Tunn, Xian 710065, Peoples R China
[4] 3 Construct Co, China Railway Engn Grp 10, Hefei 230031, Peoples R China
关键词
Railway tunnel; Blasting dust; Spray; Dust suppression; Coupling model; AIRBORNE DUST; FACE; FLOW; LAW;
D O I
10.1016/j.tust.2024.106233
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In extra-long tunnels, the dust generated by blasting excavation is difficult to discharge through ventilation, which can easily lead to secondary dust generation, severely affecting the health of construction personnel inside the tunnel and potentially increasing the construction interval. To shorten the dust removal time and enhance efficiency during tunnel blasting, this study utilized a single-hole single-track railway tunnel to conduct on-site measurements and numerical simulations of blasting dust. The effectiveness of the dust mist coupling model was validated through indoor model experiments, showing a maximum deviation of 16.94 % between the average concentration at numerical simulation monitoring points and that from model test measurements. Additionally, the model's stability was assessed using three grid sizes: coarse, medium, and fine, with the maximum relative change in dust removal rate reaching 14.75 %. In combination with the original forced ventilation system, a three-section spray dedusting method was designed. The first nozzle was positioned at the center of the forced air duct outlet, with a nozzle diameter of SH2.4 mm. The second section, located 50 m from the tunnel face, contained two nozzles placed at the top and bottom of the section. The third section, situated approximately 100 m from the tunnel face, featured two X-core circular nozzles with a diameter of 2 mm, operating at a spray pressure of 8 MPa. Nine groups of orthogonal experiments were designed using CFD, identifying the spray angle, compressed air duct volume, and spray ring spacing as the most influential factors in dust removal time. Through the addition of Experiment 10 to the orthogonal set and subsequent comparisons, the optimal spray parameters were determined to be a spray angle of 15 degrees, a compressed air duct air volume of 26 m3/s, and a spray ring spacing of 50 m. Based on the analysis of numerical results, it can be concluded that the spray dust reduction measures effectively reduced the dust concentration within 200 m of the tunnel face to a safe level 900 s after blasting.
引用
收藏
页数:19
相关论文
共 46 条
[31]  
Wang J.Y., 2019, Master thesis
[32]   Experimental characterization of multi-nozzle atomization interference for dust reduction between hydraulic supports at a fully mechanized coal mining face [J].
Wang, Jiayuan ;
Zhou, Gang ;
Wei, Xing ;
Wang, Shicong .
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2019, 26 (10) :10023-10036
[33]  
[王鹏飞 Wang Pengfei], 2016, [煤炭学报, Journal of China Coal Society], V41, P2256
[34]  
[王鹏飞 Wang Pengfei], 2015, [安全与环境学报, Journal of Safety and Environment], V15, P62
[35]  
[王鹏飞 Wang Pengfei], 2015, [煤炭学报, Journal of China Coal Society], V40, P2124
[36]   Study of high-pressure air curtain and combined dedusting of gas water spray in multilevel ore pass based on CFD-DEM [J].
Wang, Yapeng ;
Jiang, Zhongan ;
Chen, Jushi ;
Chen, Jihe ;
Wang, Ming .
ADVANCED POWDER TECHNOLOGY, 2019, 30 (09) :1789-1804
[37]  
Wigley G, 2004, EXP FLUIDS, V36, P565, DOI [10.1007/s00348-003-0690-1, 10.1007/S00348-003-0690-1]
[38]   Study on spray dust removal law for cleaner production at fully mechanized mining face with large mining height [J].
Xie, Yao ;
Cheng, Weimin ;
Yu, Haiming ;
Wang, Yuhuan .
POWDER TECHNOLOGY, 2021, 389 :48-62
[39]  
Xing S.Y., 2021, Study on dust transport law and control technology of tunnel blasting
[40]   Multi-factor numerical simulation study on spray dust suppression device in coal mining process [J].
Xu, Changwei ;
Nie, Wen ;
Liu, Zhiqiang ;
Peng, Huitian ;
Yang, Shibo ;
Liu, Qiang .
ENERGY, 2019, 182 :544-558