Spray dust control measures of tunnel blasting dust based on CFD dust-droplet coupling model and orthogonal test

被引:3
作者
Chen, Zheng [1 ]
Zhao, Shulei [1 ]
Dong, Chen [2 ]
Wang, Shuaishuai [3 ]
Guo, Yabin [3 ]
Gao, Xuan [3 ]
Sun, Bing [4 ]
Chen, Wengan [4 ]
Guo, Chun [1 ]
机构
[1] Southwest Jiaotong Univ, Coll Civil Engn, Key Lab Transportat Tunnel Engn, MOE, Chengdu, Peoples R China
[2] Southwest Jiaotong Univ, Sch Transportat & Logist, Chengdu, Peoples R China
[3] CCCC Second Highway Engn Co Ltd, Res & Dev Ctr Construct Technol Long Bridge & Tunn, Xian 710065, Peoples R China
[4] 3 Construct Co, China Railway Engn Grp 10, Hefei 230031, Peoples R China
关键词
Railway tunnel; Blasting dust; Spray; Dust suppression; Coupling model; AIRBORNE DUST; FACE; FLOW; LAW;
D O I
10.1016/j.tust.2024.106233
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In extra-long tunnels, the dust generated by blasting excavation is difficult to discharge through ventilation, which can easily lead to secondary dust generation, severely affecting the health of construction personnel inside the tunnel and potentially increasing the construction interval. To shorten the dust removal time and enhance efficiency during tunnel blasting, this study utilized a single-hole single-track railway tunnel to conduct on-site measurements and numerical simulations of blasting dust. The effectiveness of the dust mist coupling model was validated through indoor model experiments, showing a maximum deviation of 16.94 % between the average concentration at numerical simulation monitoring points and that from model test measurements. Additionally, the model's stability was assessed using three grid sizes: coarse, medium, and fine, with the maximum relative change in dust removal rate reaching 14.75 %. In combination with the original forced ventilation system, a three-section spray dedusting method was designed. The first nozzle was positioned at the center of the forced air duct outlet, with a nozzle diameter of SH2.4 mm. The second section, located 50 m from the tunnel face, contained two nozzles placed at the top and bottom of the section. The third section, situated approximately 100 m from the tunnel face, featured two X-core circular nozzles with a diameter of 2 mm, operating at a spray pressure of 8 MPa. Nine groups of orthogonal experiments were designed using CFD, identifying the spray angle, compressed air duct volume, and spray ring spacing as the most influential factors in dust removal time. Through the addition of Experiment 10 to the orthogonal set and subsequent comparisons, the optimal spray parameters were determined to be a spray angle of 15 degrees, a compressed air duct air volume of 26 m3/s, and a spray ring spacing of 50 m. Based on the analysis of numerical results, it can be concluded that the spray dust reduction measures effectively reduced the dust concentration within 200 m of the tunnel face to a safe level 900 s after blasting.
引用
收藏
页数:19
相关论文
共 46 条
[1]  
[Anonymous], 2023, T/CSRME 029-2023
[2]   Three-stage numerical simulation of tunnel blasting dust diffusion based on field monitoring and CFD [J].
Chen, Zheng ;
Zhao, Shulei ;
Dong, Chen ;
Wang, Shuaishuai ;
Guo, Yabin ;
Gao, Xuan ;
Sun, Bing ;
Chen, Wengan ;
Guo, Chun .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2024, 150
[3]   COLLECTION OF AIRBORNE DUST BY WATER SPRAYS [J].
CHENG, L .
INDUSTRIAL & ENGINEERING CHEMISTRY PROCESS DESIGN AND DEVELOPMENT, 1973, 12 (03) :221-225
[4]   How do dunes along a desert urban motorway affect the driving safety of sedans? Evidences from long- and short-term monitoring and IDDES [J].
Deng, E. ;
Liu, Xin-Yuan ;
Yue, Huan ;
Yang, Wei-Chao ;
Ouyang, De-Hui ;
Ni, Yi-Qing .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2023, 243
[5]   Aerodynamic impact of wind-sand flow on moving trains in tunnel-embankment transition section: from field testing to CFD modeling [J].
Deng, E. ;
Yue, Huan ;
Liu, Xin-Yuan ;
Ni, Yi-Qing .
ENGINEERING APPLICATIONS OF COMPUTATIONAL FLUID MECHANICS, 2023, 17 (01)
[6]  
Fluent A N. S. Y. S., 2020, Ansys fluent theory guide
[7]  
[龚景松 GONG Jingsong], 2006, [热能动力工程, Journal of Engineering for Thermal Energy and Power], V21, P632
[8]   Effect of water supply pressure on atomization characteristics and dust-reduction efficiency of internal mixing air atomizing nozzle [J].
Han, Han ;
Wang, Pengfei ;
Li, Yongjun ;
Liu, Ronghua ;
Tian, Chang .
ADVANCED POWDER TECHNOLOGY, 2020, 31 (01) :252-268
[9]  
[蒋仲安 Jiang Zhong'an], 2023, [煤炭学报, Journal of China Coal Society], V48, P263
[10]  
[蒋仲安 Jiang Zhong'an], 2017, [哈尔滨工业大学学报, Journal of Harbin Institute of Technology], V49, P151