A Geant4 Monte Carlo toolkit-based radiative transfer model for studying the impact of aerosols

被引:0
|
作者
Boudjella, M. Y. [1 ]
Belbachir, A. H. [1 ]
Dib, A. S. A. [1 ]
Meftah, M. [2 ]
机构
[1] Univ Sci & Technol Oran Mohamed Boudiaf USTO MB, Fac Phys, Lab Anal & Applicat Radiat LAAR, BP 1505, Oran 31000, Algeria
[2] Univ Paris Saclay, Sorbonne Univ, Univ Versailles St Quentin En Yvelines, Lab Atmospheres Milieux Observat Spatiales LATMOS,, 11 Blvd Alembert, F-78280 Guyancourt, France
关键词
Geant4; DISORT code; Global irradiance; Diffuse irradiance; TOA reflected irradiance; Radiative forcing; SKY SOLAR IRRADIANCE; PHOTOSYNTHETICALLY ACTIVE RADIATION; LIBRADTRAN SOFTWARE PACKAGE; MULTIPLE-SCATTERING; PART I; ATMOSPHERE; CODE; PERFORMANCE; VALIDATION; VERSION;
D O I
10.1016/j.asr.2024.07.057
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Radiative transfer models are of prime importance in quantifying the earth-atmosphere energy budget. A radiative transfer model based on the Geant4 Monte Carlo toolkit was developed. This model is able to perform calculations of the spectral atmospheric transmittance, surface solar irradiance, as well as the Top of the Atmosphere (TOA) reflected irradiance over the spectral range from 280 nm to 3000 nm. Through this study, the Geant4 toolkit was used to study the effect of rural aerosols concentration on different radiative characteristics. Geant4 radiative calculations in the presence and absence of aerosols were compared to that of DISORT code. For both surface and Top of the atmosphere simulations, good agreement was observed between the two models. Specifically, under atmospheric visibility conditions of 23 km, the mean relative difference between Geant4 and DISORT code was found to be less than 2.46 % for Global irradiance calculations and less than 7.9 % for TOA reflected irradiance. A comparative analysis between the measured total global irradiance in Adrar city and the irradiance estimated by Geant4 demonstrated the general effectiveness of Geant4, with a coefficient of determination of 0.991 and a Mean Absolute Percentage Error (MAPE) of 5.851 %.<br /> (c) 2024 COSPAR. Published by Elsevier B.V. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
引用
收藏
页码:74 / 90
页数:17
相关论文
共 48 条
  • [21] Monte Carlo calculations of electrons impinging on a copper target: A comparison of EGSnrc, Geant4 and MCNP5
    Archambault, John Paul
    APPLIED RADIATION AND ISOTOPES, 2018, 132 : 129 - 134
  • [22] MONTE-CARLO RADIATIVE TRANSFER MODEL OF THE DIFFUSE GALACTIC LIGHT
    Seon, Kwang-Il
    JOURNAL OF THE KOREAN ASTRONOMICAL SOCIETY, 2015, 48 (01) : 57 - 66
  • [23] A sourceless efficiency calibration model of airborne γ-spectrometry based on Geant4
    Mei, Cong
    Fu, Chen
    Zhang, Wei
    Li, Jiangkun
    Liang, Xudong
    Wu, Xue
    Luo, Qibin
    Yang, Yaxin
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2025, 57 (08)
  • [24] Specific absorbed fractions of electrons and photons for Digimouse voxelized phantom using GATE/GEANT4 Monte-Carlo simulation
    Laazouzi, Khaoula
    Boukhal, Hamid
    Chakir, El Mahjoub
    Arectout, Assia
    Hadouachi, Maryam
    Belhaj, Omaima Essaad
    APPLIED RADIATION AND ISOTOPES, 2023, 193
  • [25] Evaluation of the dose perturbation around gold and steel fiducial markers in a medical linac through Geant4 Monte Carlo simulation
    Pontoriero, Antonio
    Amato, Ernesto
    Iati, Giuseppe
    De Renzis, Costantino
    Pergolizzi, Stefano
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2015, 23 (02) : 135 - 140
  • [26] Scintillation event localization in hemi-ellipsoid detector for SPECT, a simulation study using Geant4 Monte-Carlo
    Soysal, H. R.
    Dey, J.
    Donahue, W. P.
    Matthews, K. L.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (05)
  • [27] Feasibility of using Geant4 Monte Carlo simulation for IMRT dose calculations for the Novalis Tx with a HD-120 multi-leaf collimator
    Jung, Hyunuk
    Shin, Jungsuk
    Chung, Kwangzoo
    Han, Youngyih
    Kim, Jinsung
    Choi, Doo Ho
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 66 (10) : 1489 - 1494
  • [28] Evaluation of GATE-RTion (GATE/Geant4) Monte Carlo simulation settings for proton pencil beam scanning quality assurance
    Winterhalter, Carla
    Taylor, Michael
    Boersma, David
    Elia, Alessio
    Guatelli, Susanna
    Mackay, Ranald
    Kirkby, Karen
    Maigne, Lydia
    Ivanchenko, Vladimir
    Resch, Andreas F.
    Sarrut, David
    Sitch, Peter
    Vidal, Marie
    Grevillot, Loic
    Aitkenhead, Adam
    MEDICAL PHYSICS, 2020, 47 (11) : 5817 - 5828
  • [29] Monte Carlo simulation of ruthenium eye plaques with GEANT4: influence of multiple scattering algorithms, the spectrum and the geometry on depth dose profiles
    Sommer, H.
    Ebenau, M.
    Spaan, B.
    Eichmann, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (05) : 1848 - 1864
  • [30] A Functionalized Monte Carlo 3D Radiative Transfer Model: Radiative Effects of Clouds Over Reflecting Surfaces
    Villefranque, Najda
    Barker, Howard W. W.
    Cole, Jason N. S.
    Qu, Zhipeng
    JOURNAL OF ADVANCES IN MODELING EARTH SYSTEMS, 2023, 15 (07)