A Geant4 Monte Carlo toolkit-based radiative transfer model for studying the impact of aerosols

被引:0
|
作者
Boudjella, M. Y. [1 ]
Belbachir, A. H. [1 ]
Dib, A. S. A. [1 ]
Meftah, M. [2 ]
机构
[1] Univ Sci & Technol Oran Mohamed Boudiaf USTO MB, Fac Phys, Lab Anal & Applicat Radiat LAAR, BP 1505, Oran 31000, Algeria
[2] Univ Paris Saclay, Sorbonne Univ, Univ Versailles St Quentin En Yvelines, Lab Atmospheres Milieux Observat Spatiales LATMOS,, 11 Blvd Alembert, F-78280 Guyancourt, France
关键词
Geant4; DISORT code; Global irradiance; Diffuse irradiance; TOA reflected irradiance; Radiative forcing; SKY SOLAR IRRADIANCE; PHOTOSYNTHETICALLY ACTIVE RADIATION; LIBRADTRAN SOFTWARE PACKAGE; MULTIPLE-SCATTERING; PART I; ATMOSPHERE; CODE; PERFORMANCE; VALIDATION; VERSION;
D O I
10.1016/j.asr.2024.07.057
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Radiative transfer models are of prime importance in quantifying the earth-atmosphere energy budget. A radiative transfer model based on the Geant4 Monte Carlo toolkit was developed. This model is able to perform calculations of the spectral atmospheric transmittance, surface solar irradiance, as well as the Top of the Atmosphere (TOA) reflected irradiance over the spectral range from 280 nm to 3000 nm. Through this study, the Geant4 toolkit was used to study the effect of rural aerosols concentration on different radiative characteristics. Geant4 radiative calculations in the presence and absence of aerosols were compared to that of DISORT code. For both surface and Top of the atmosphere simulations, good agreement was observed between the two models. Specifically, under atmospheric visibility conditions of 23 km, the mean relative difference between Geant4 and DISORT code was found to be less than 2.46 % for Global irradiance calculations and less than 7.9 % for TOA reflected irradiance. A comparative analysis between the measured total global irradiance in Adrar city and the irradiance estimated by Geant4 demonstrated the general effectiveness of Geant4, with a coefficient of determination of 0.991 and a Mean Absolute Percentage Error (MAPE) of 5.851 %.<br /> (c) 2024 COSPAR. Published by Elsevier B.V. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
引用
收藏
页码:74 / 90
页数:17
相关论文
共 48 条
  • [1] Calculation of surface spectral irradiance using the Geant4 Monte Carlo toolkit
    Boudjella, Manal Yasmine
    Belbachir, Ahmed Hafid
    Dib, Samy Anis Amine
    Meftah, Mustapha
    JOURNAL OF ATMOSPHERIC AND SOLAR-TERRESTRIAL PHYSICS, 2023, 248
  • [2] Cellular Dosimetry Using the Geant4 Monte Carlo Toolkit REPLY
    Cai, Zhongli
    Pignol, Jean-Philippe
    Chan, Conrad
    Reilly, Raymond M.
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (09) : 1489 - 1489
  • [3] Monte Carlo modeling and validation of a proton treatment nozzle by using the Geant4 toolkit
    Kim, Dae-Hyun
    Kang, Young Nam
    Suh, Tae-Suk
    Shin, Jungwook
    Kim, Jong Won
    Yoo, Seung Hoon
    Park, Seyjoon
    Lee, Sang Hoon
    Cho, Sungkoo
    Shin, Dongho
    Kim, Dae Yong
    Lee, Se Byeong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 61 (07) : 1125 - 1130
  • [4] Monte Carlo modeling and validation of a proton treatment nozzle by using the Geant4 toolkit
    Dae-Hyun Kim
    Young Nam Kang
    Tae-Suk Suh
    Jungwook Shin
    Jong Won Kim
    Seung Hoon Yoo
    Seyjoon Park
    Sang Hoon Lee
    Sungkoo Cho
    Dongho Shin
    Dae Yong Kim
    Se Byeong Lee
    Journal of the Korean Physical Society, 2012, 61 : 1125 - 1130
  • [5] Monte Carlo method for gamma spectrometry based on GEANT4 toolkit: Efficiency calibration of BE6530 detector
    Joel, Guembou Shouop Cebastien
    Maurice, Ndontchueng Moyo
    Jilbert, Nguelem Mekongtso Eric
    Ousmanou, Motapon
    David, Strivay
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2018, 189 : 109 - 119
  • [6] Validation of GEANT4, an object-oriented Monte Carlo toolkit, for simulations in medical physics
    Carrier, JF
    Archambault, L
    Beaulieu, L
    Roy, R
    MEDICAL PHYSICS, 2004, 31 (03) : 484 - 492
  • [7] Characterizing a Geant4 Monte Carlo model of a multileaf collimator for a TrueBeam™ linear accelerator
    Kandlakunta, Praneeth
    Momin, Shadab
    Sloop, Austin
    Zhang, Tiezhi
    Khan, Rao
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 59 : 1 - 12
  • [8] Benchmarking a GATE/Geant4 Monte Carlo model for proton beams in magnetic fields
    Padilla-Cabal, Fatima
    Alejandro Fragoso, Jose
    Resch, Andreas Franz
    Georg, Dietmar
    Fuchs, Hermann
    MEDICAL PHYSICS, 2020, 47 (01) : 223 - 233
  • [9] A computationally efficient moment-preserving Monte Carlo proton transport method in Geant4
    Dixon, D. A.
    Prinja, A. K.
    McCartney, A. P.
    Hughes, H. G.
    ICRS-13 & RPSD-2016, 13TH INTERNATIONAL CONFERENCE ON RADIATION SHIELDING & 19TH TOPICAL MEETING OF THE RADIATION PROTECTION AND SHIELDING DIVISION OF THE AMERICAN NUCLEAR SOCIETY - 2016, 2017, 153
  • [10] Validating Geant4 with Monte Carlo simulations in the context of nuclear disarmament verification
    Kreutle, Manuel
    Borella, Alessandro
    Hebel, Simon
    Kirchner, Gerald
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1057