Automatic fault location method for traveling wave on HVDC transmission line using single-terminal data

被引:0
作者
机构
[1] School of Electrical Engineering, Xi'an Jiaotong University
[2] State Power Economic Research Institute of Jibei
来源
Jin, D. (nealdh@stu.xjtu.edu.cn) | 1600年 / Science Press卷 / 40期
关键词
Automatic; DC filter; DC transmission line; Fault location; Single-ended; Traveling wave;
D O I
10.13336/j.1003-6520.hve.2014.02.035
中图分类号
学科分类号
摘要
Traditional traveling wave methods for locating faults on transmission lines have the deficiency of being hard to catch the second wave head and unable to automatically achieve. A novel automatic method to the single-ended traveling wave fault location for CSC-HVDC transmission lines is presented. When a fault occurs on a DC line, the DC filter and the smoothing reactor which are located in the end of the DC line constitute a physic boundary for the voltage traveling wave, and the boundary will cause total reflection to high-frequency traveling voltage waves. Since the refraction of the traveling wave at the fault point is much stronger than the reflection, based on the distributed parameter model, the voltage distribution of the DC line can be calculated by using the high-frequency voltage and current measured in the local terminal. Therefore, the fault can be located by seeking the strongest superposition point that is constituted by the forward and back voltage waves. Different from traditional traveling wave methods, the proposed method does not need to catch the second wave head and it is automatic. Simulation results show that this method has satisfying accuracy that the error of 1000 km is only 800 meter, and its results are free from the influence of transition resistance.
引用
收藏
页码:588 / 596
页数:8
相关论文
共 24 条
  • [11] Song G., Cai X., Gao S., Et al., New pilot protection for VSC-HVDC transmission line using natural frequency characteristic of current, High Voltage Engineering, 37, 8, pp. 1-6, (2011)
  • [12] Murthy P.K., Amarnath J., Kamakshiah S., Et al., Wavelet transform approach for detection and location of faults in HVDC system, 2008 IEEE Region 10 Colloquium and the Third ICIIS, pp. 8-10, (2008)
  • [13] Chen P., Xu B., Li J., Et al., Modern travelling wave based fault location techniques for HVDC transmission lines, Transactions on Tianjin University, 14, 2, pp. 4-7, (2008)
  • [14] Shu H., Zhang M., Zhang G., Et al., A RG color pattern detection of single-ended traveling wave fault location on ±800 kV UHVDC transmission lines, Transactions of China Electrotechnical Society, 25, 11, pp. 155-163, (2010)
  • [15] Liao K., He Z., Li X., A novel faultlocation method for HVDC transmission lines based on natural frequency of traveling wave, Automation of Electric Power Systems, 36, 18, pp. 1-6, (2012)
  • [16] Song G., Zhou D., Jiao Z., Et al., A novel fault location principle for HVDC transmission line, Automation of Electric Power Systems, 31, 24, pp. 57-61, (2007)
  • [17] Gao S., Suonan J., Song G., Et al., Fault location method for HVDC transmission lines on the basis of the distributed parameter model, Proceedings of the CSEE, 30, 13, pp. 75-80, (2010)
  • [18] Cai X., Song G., Gao S., Et al., A novel fault-location method for VSC-HVDC transmission lines based on natural frequency of current, Proceedings of the CSEE, 31, 28, pp. 112-119, (2011)
  • [19] Song G., Li D., Chu X., Et al., One-terminal fault location for VSC-HVDC transmission lines based on principles of parameter identification, Power System Technology, 36, 12, pp. 94-99, (2012)
  • [20] Song G., Suonan J., Xu Q., Et al., Fault location for parallel transmission lines on the same tower based on one-terminal current, Relay, 32, 7, pp. 1-6, (2004)