Cuff-less and continuous blood pressure measurement based on pulse transit time from carotid and toe photoplethysmograms

被引:3
|
作者
Zuhair Sameen A. [1 ]
Jaafar R. [2 ]
Zahedi E. [3 ]
Kok Beng G. [2 ]
机构
[1] Department of Medical Instrumentation Engineering Techniques, College of Medical Techniques, Al-Farahidi University, Baghdad
[2] Department of Electrical Electronic and Systems Engineering, Faculty of Engineering, and Built Environment, University Kebangsaan Malaysia (UKM), Bangi
[3] SwifTek Consulting, Vancouver
来源
Journal of Medical Engineering and Technology | 2022年 / 46卷 / 07期
关键词
blood pressure (BP); electrocardiogram (ECG); photoplethysmogram (PPG); Pulse transit time (PTT); pulse wave velocity (PWV); system identification (SI);
D O I
10.1080/03091902.2022.2077998
中图分类号
学科分类号
摘要
Blood pressure (BP) is a vital health parameter that varies throughout the day. As a single reading of high BP may not indicate hypertension, continuous monitoring of BP is usually recommended by medical doctors to confirm the diagnosis of hypertension. In the last few decades, researchers have investigated cuff-less and continuous BP measurements based on pulse transit time (PTT). The main purpose of this research is to develop an autoregressive (ARX) system identification (SI)-based PTT calculation model using two PPG signals acquired from carotid and toe. The signals were recorded from 65 subjects with an age range between 20 and 60 years. The results of the study have been validated in two stages. The first validation comprised the estimated BP from PTT using SI compared to the measured BP using the cuff-based method for all subjects. The results of the estimated BP using the proposed method compared to the measured BP obtained using the standard BP cuff measurement method are highly correlated to both systolic blood pressure (R 2 = 0.8132) and diastolic blood pressure (R 2 = 0.8357). The second validation consisted of comparing PTT values using system identification to the results of the PTT derived from the ECG–PPG method. The results showed that both methods are highly correlated (R 2 = 0.7808), and there is no significant difference between them (p < 0.05) with a slightly better PTT estimation related to DBP in the proposed method. Our results have proven that the PTT obtained from the carotid PPG and toe PPG using the system identification approach yielded SBP and DBP estimations that are consistent with the values of the conventional BP cuff method. The newly proposed method has the advantage of being cuff-less and able to provide continuous BP measurements. © 2022 Informa UK Limited, trading as Taylor & Francis Group.
引用
收藏
页码:567 / 589
页数:22
相关论文
共 25 条
  • [1] Implementation of Cuff-less Continuous Blood Pressure Measurement System Based on Android
    Xu, Lisheng
    Guo, Xu
    Yang, Feifei
    Yin, Sainan
    Zhang, Xibin
    Meng, Max Q. -H.
    PROCEEDING OF THE IEEE INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION, 2012, : 552 - 556
  • [2] EDifferential Pulse Arrival Time: A Novel Approach to Continuous Cuff-less Blood Pressure Monitoring
    Pandit, Jay A.
    Miller, Kyle
    Wu, Jung-en
    Connell, Sean D.
    Shah, Sanjiv
    CIRCULATION, 2016, 134
  • [3] Differential Pulse Arrival Time: A Novel Approach to Continuous Cuff-less Blood Pressure Monitoring
    Pandit, Jay A.
    Miller, Kyle
    Wu, Jung-en
    Connell, Sean D.
    Shah, Sanjiv
    CIRCULATION, 2016, 134
  • [4] Cuff-less Blood Pressure measurement from Wireless ECG and PPG signals
    Dave, Tejal
    Pandya, Utpal
    Joshi, Maulin
    2021 IEEE INTERNATIONAL SYMPOSIUM ON SMART ELECTRONIC SYSTEMS (ISES 2021), 2021, : 33 - 37
  • [5] An Armband Wearable Device for Overnight and Cuff-Less Blood Pressure Measurement
    Zheng, Ya-Li
    Yan, Bryan P.
    Zhang, Yuan-Ting
    Poon, Carmen C. Y.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (07) : 2179 - 2186
  • [6] Distributed Model Architecture for Cuff-Less Blood Pressure Measurement System
    Dave T.
    Joshi M.
    Pandya U.
    SN Computer Science, 3 (6)
  • [7] PPG Sensor Contact Pressure Should Be Taken Into Account for Cuff-Less Blood Pressure Measurement
    Chandrasekhar, Anand
    Yavarimanesh, Mohammad
    Natarajan, Keerthana
    Hahn, Jin-Oh
    Mukkamala, Ramakrishna
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (11) : 3134 - 3140
  • [8] Cuff-less blood pressure measurement using fingertip photoplethysmogram signals and physiological characteristics
    Yang, S.
    Zhang, Y.
    Cho, Siu-Yeung
    Morgan, Stephen P.
    Correia, Ricardo
    Wen, L.
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS VIII, 2018, 10820
  • [9] A Novel Method for Continuous, Noninvasive, Cuff-Less Measurement of Blood Pressure: Evaluation in Patients With Nonalcoholic Fatty Liver Disease
    Seeberg, Trine M.
    Orr, James G.
    Opsahl, Hanne
    Austad
    Roed, Morten H.
    Dalgard, Steffen H.
    Houghton, David
    Jones, David E. J.
    Strisland, Frode
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (07) : 1469 - 1478
  • [10] Coefficient-Free Blood Pressure Estimation Based on Pulse Transit Time-Cuff Pressure Dependence
    Forouzanfar, Mohamad
    Ahmad, Saif
    Batkin, Izmail
    Dajani, Hilmi R.
    Groza, Voicu Z.
    Bolic, Miodrag
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (07) : 1814 - 1824