Performance simulation of dual pressure HRSG in combined cycle power plant

被引:0
|
作者
机构
来源
Energy Eng | 2007年 / 1卷 / 64-78期
关键词
Combined cycle power plants - Exhaust gases - Gas turbine power plants - Gas turbines - Steam engineering - Steam generators - Steam power plants - Steam turbines - Waste heat utilization;
D O I
10.1080/01998590709509487
中图分类号
学科分类号
摘要
Combined cycle power plants play an important role in the present energy sector. The main challenge in designing a combined cycle power plant is how to transfer gas turbine exhaust heat to the steam cycle to achieve optimum steam turbine output. Most of the combined cycle developers focus on the gas turbine and steam turbine, but the performance of the heat recovery steam generator (HRSG) strongly affects the overall performance of the combined cycle power plant. Therefore, the present article undertakes the problem of optimal utilization of the waste heat from gas turbine exhaust with dual pressure HRSG confi guration. The combined cycle effi ciency has been analyzed parametrically from both the first and second law of thermodynamics. It is observed that in the dual cycle the high-pressure steam pressure must be relatively high, and low-pressure steam pressure must be low for better heat recovery from HRSG.
引用
收藏
相关论文
共 50 条
  • [21] Exergo-economic study of a dual-pressure HRSG in gas/steam combined cycle plants
    Sharma, Meeta
    Singh, Onkar
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2020, 41 (01) : 50 - 57
  • [22] OPTIMIZATION OF THE TRIPLE-PRESSURE COMBINED CYCLE POWER PLANT
    Alus, Muammer
    Petrovic, Milan V.
    THERMAL SCIENCE, 2012, 16 (03): : 901 - 914
  • [23] Modelling and simulation of the effect of ambient parameters on the performance of a combined cycle gas turbine power plant
    Plis, Marcin
    Rusinowski, Henryk
    PROCEEDINGS OF THE 2016 17TH INTERNATIONAL CARPATHIAN CONTROL CONFERENCE (ICCC), 2016, : 590 - 595
  • [24] Multi-criteria performance analysis of dual miller cycle-Organic rankine cycle combined power plant
    Zerom, Merhawi Samuel
    Gonca, Guven
    ENERGY CONVERSION AND MANAGEMENT, 2020, 221
  • [25] Performance improvement of heat recovery steam generator (HRSG) in combined cycle power plant by replacing tube of HP economizer and HP evaporator
    Adi, Waskito
    Caesarendra, Wahyu
    2021 11TH INTERNATIONAL CONFERENCE ON POWER, ENERGY AND ELECTRICAL ENGINEERING (CPEEE 2021), 2021, : 266 - 271
  • [26] Performance optimization of a new combined power cycle based on power density analysis of the dual cycle
    Sahin, B
    Kesgin, U
    Kodal, A
    Vardar, N
    ENERGY CONVERSION AND MANAGEMENT, 2002, 43 (15) : 2019 - 2031
  • [27] The optimum performance of the combined cycle power plant: A comprehensive review
    Ibrahim, Thamir K.
    Mohammed, Mohammed Kamil
    Awad, Omar I.
    Rahman, M. M.
    Najafi, G.
    Basrawi, Firdaus
    Abd Alla, Ahmed N.
    Mamat, Rizalman
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 79 : 459 - 474
  • [28] Effect of supplementary firing on the performance of a combined cycle power plant
    Abdollahian, Afshin
    Ameri, Mehran
    APPLIED THERMAL ENGINEERING, 2021, 193
  • [29] Aligning Combined Cycle Power Plant Performance with Field Measurements
    Najjar, Yousef S. H.
    Manaserh, Yaman Mohammad Ali
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2019, 44 (02) : 1657 - 1669
  • [30] PERFORMANCE TESTING OF COMBINED CYCLE POWER PLANT IN PHASED CONSTRUCTION
    Jin, Hugh
    Sullivan, Terrence B.
    Friedman, Jeffrey R.
    ASME POWER CONFERENCE, 2010, 2010, : 865 - 871