Shipboard Medium-Voltage DC Integrated Power System Ⅱ: Protection and Fault Management Technology

被引:0
|
作者
Yang, Yayu [1 ,2 ]
Tai, Nengling [2 ,3 ]
Huang, Wentao [2 ]
Yu, Moduo [2 ]
Liu, Yu [4 ]
机构
[1] Logistics Engineering College, Shanghai Maritime University, Shanghai,201306, China
[2] Key Laboratory of Control of Power Transmission and Conversion, Ministry of Education, Shanghai Jiao Tong University, Shanghai,200240, China
[3] College of Smart Energy, Shanghai Jiao Tong University, Shanghai,200240, China
[4] School of Information Science and Technology, ShanghaiTech University, Shanghai,201210, China
关键词
Transient analysis;
D O I
10.19595/j.cnki.1000-6753.tces.231646
中图分类号
学科分类号
摘要
The shipboard medium-voltage DC (MVDC) integrated power system (IPS) is the technological development direction of the shipboard IPS. As the second part, this paper focuses on the protection and fault management technology of the shipboard MVDC IPS, which includes four parts: fault characteristics analysis, protection principle, fault isolation scheme and reconfiguration method. First of all, the special technical requirements for the protection and fault management technology are analyzed. The shipboard MVDC IPS has high requirements for selectivity and speed. The protection and fault management scheme needs to fully consider the shipboard multiple operating modes and the transient response of multi-type power electronic converters. Then, the fault characteristics analysis method and the protection principle are summarized, and the limitations are outlined. Subsequently, the fault isolation scheme and reconfiguration method are comprehensive reviewed, and the detailed comparisons are made respectively. Finally, the future research trends of the protection and fault management technology of the shipboard MVDC IPS are pointed out. 1) Fault characteristics analysis. The fault transient characteristics analysis methods based on time-frequency domain transformation, nodal impedance matrix analysis, topology simplification, and pole-mode transformation analysis in multi-terminal DC (MTDC) transmission and distribution system provide important references for the shipboard MVDC IPS. However, the fault characteristic analysis model of the complex topology shipboard MVDC IPS containing multi-type power electronic converters, multiple system nodes and multiple operating modes still needs to be studied. 2) Protection principle. Intelligent protection methods require a large amount of training data, which limits the engineering applications. The shipboard MVDC IPS protection can draw on the existing MTDC transmission and distribution system protection method to a certain extent. However, due to the short ship cables, inconsistent DC line boundaries, multiple system nodes, and complex topology, more detailed and in-depth research is still needed. 3) Fault isolation scheme. The hybrid DC circuit breaker (DCCB) has the advantages of low on-state loss of mechanical DC circuit breaker (MCB) and fast breaking speed of solid-state DCCB, which is one of the main technological development directions of DCCB. Currently, the fault isolation scheme based on inductive DC fault current limiter (DCFCL) and DCCB is more suitable for the shipboard MVDC IPS. The simple topology and low cost-based current-limiting DCCB and the high reliability multi-port DCCB are the future research directions. 4) Reconfiguration method. Combining the advantages of centralized manner-based reconfiguration methods and distributed reconfiguration methods, the muti-level distributed reconfiguration method is a meaningful research direction. What is more, the objective function and constraints of the shipboard MVDC IPS reconfiguration method require further study. © 2024 China Machine Press. All rights reserved.
引用
收藏
页码:7341 / 7364
相关论文
共 50 条
  • [41] Controller Optimization for Bidirectional Power Flow in Medium-Voltage DC Power Systems
    Chung, Il-Yop
    Liu, Wenxin
    Cartes, David A.
    Cho, Soo-Hwan
    Kang, Hyun-Koo
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2011, 6 (06) : 750 - 759
  • [42] Fault Detection of the Medium-Voltage DC Cable by Using the Featured Modal Signals
    Peng, Nan
    Xu, Lihua
    Liang, Rui
    Zhou, Guangyang
    Zhang, Peng
    Jin, Mohan
    Hou, Meng
    Li, Jian
    Pan, Yihang
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2024, 20 (08) : 10473 - 10487
  • [43] Medium-voltage power line carrier communication system
    Xiao, H
    Zeng, XJ
    Fan, SS
    Wu, XB
    Kuang, L
    2004 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY - POWERCON, VOLS 1 AND 2, 2004, : 1536 - 1539
  • [44] Generation control system for improving design and stability of medium-voltage DC power systems on ships
    Arcidiacono, V.
    Monti, A.
    Sulligoi, G.
    IET ELECTRICAL SYSTEMS IN TRANSPORTATION, 2012, 2 (03) : 158 - 167
  • [45] Comprehensive Protection of Medium-Voltage Microgrids
    Ranjbar, Siavash
    Jamali, Sadegh
    2014 SMART GRID CONFERENCE (SGC), 2014,
  • [46] Core balance ground fault protection of motors on a low-resistance grounded, medium-voltage system
    Breitkreutz, B
    Frere, A
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1995, 31 (06) : 1398 - 1401
  • [47] A High-Power Density DC Converter for Medium-Voltage DC Distribution Networks
    Wan, Dai
    Zhou, Qianfan
    Duan, Xujin
    Zhu, Jiran
    Li, Junhao
    Zhou, Hengyi
    ELECTRONICS, 2023, 12 (18)
  • [48] Fault Detection and Isolation in Medium-Voltage DC Microgrids: Coordination Between Supply Power Converters and Bus Contactors
    Cairoli, Pietro
    Dougal, Roger A.
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (05) : 4535 - 4546
  • [49] PROVIDING BETTER PROTECTION FOR MEDIUM-VOLTAGE POWER DISTRIBUTION-SYSTEMS
    SMITH, RL
    PLANT ENGINEERING, 1978, 32 (12) : 139 - 143
  • [50] Legal guarantee of bird protection on medium-voltage overhead power lines
    Hellermann J.
    Natur und Recht, 2018, 40 (12) : 805 - 812