Shipboard Medium-Voltage DC Integrated Power System Ⅱ: Protection and Fault Management Technology

被引:0
|
作者
Yang, Yayu [1 ,2 ]
Tai, Nengling [2 ,3 ]
Huang, Wentao [2 ]
Yu, Moduo [2 ]
Liu, Yu [4 ]
机构
[1] Logistics Engineering College, Shanghai Maritime University, Shanghai,201306, China
[2] Key Laboratory of Control of Power Transmission and Conversion, Ministry of Education, Shanghai Jiao Tong University, Shanghai,200240, China
[3] College of Smart Energy, Shanghai Jiao Tong University, Shanghai,200240, China
[4] School of Information Science and Technology, ShanghaiTech University, Shanghai,201210, China
关键词
Transient analysis;
D O I
10.19595/j.cnki.1000-6753.tces.231646
中图分类号
学科分类号
摘要
The shipboard medium-voltage DC (MVDC) integrated power system (IPS) is the technological development direction of the shipboard IPS. As the second part, this paper focuses on the protection and fault management technology of the shipboard MVDC IPS, which includes four parts: fault characteristics analysis, protection principle, fault isolation scheme and reconfiguration method. First of all, the special technical requirements for the protection and fault management technology are analyzed. The shipboard MVDC IPS has high requirements for selectivity and speed. The protection and fault management scheme needs to fully consider the shipboard multiple operating modes and the transient response of multi-type power electronic converters. Then, the fault characteristics analysis method and the protection principle are summarized, and the limitations are outlined. Subsequently, the fault isolation scheme and reconfiguration method are comprehensive reviewed, and the detailed comparisons are made respectively. Finally, the future research trends of the protection and fault management technology of the shipboard MVDC IPS are pointed out. 1) Fault characteristics analysis. The fault transient characteristics analysis methods based on time-frequency domain transformation, nodal impedance matrix analysis, topology simplification, and pole-mode transformation analysis in multi-terminal DC (MTDC) transmission and distribution system provide important references for the shipboard MVDC IPS. However, the fault characteristic analysis model of the complex topology shipboard MVDC IPS containing multi-type power electronic converters, multiple system nodes and multiple operating modes still needs to be studied. 2) Protection principle. Intelligent protection methods require a large amount of training data, which limits the engineering applications. The shipboard MVDC IPS protection can draw on the existing MTDC transmission and distribution system protection method to a certain extent. However, due to the short ship cables, inconsistent DC line boundaries, multiple system nodes, and complex topology, more detailed and in-depth research is still needed. 3) Fault isolation scheme. The hybrid DC circuit breaker (DCCB) has the advantages of low on-state loss of mechanical DC circuit breaker (MCB) and fast breaking speed of solid-state DCCB, which is one of the main technological development directions of DCCB. Currently, the fault isolation scheme based on inductive DC fault current limiter (DCFCL) and DCCB is more suitable for the shipboard MVDC IPS. The simple topology and low cost-based current-limiting DCCB and the high reliability multi-port DCCB are the future research directions. 4) Reconfiguration method. Combining the advantages of centralized manner-based reconfiguration methods and distributed reconfiguration methods, the muti-level distributed reconfiguration method is a meaningful research direction. What is more, the objective function and constraints of the shipboard MVDC IPS reconfiguration method require further study. © 2024 China Machine Press. All rights reserved.
引用
收藏
页码:7341 / 7364
相关论文
共 50 条
  • [21] Study of Liquid Metal Fault Current Limiter for Medium-Voltage DC Power Systems
    He, Hailong
    Wu, Yi
    Yang, Zhuo
    Zhao, Peng
    Zhu, Xiaonan
    Niu, Chunping
    Rong, Mingzhe
    IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY, 2018, 8 (08): : 1391 - 1400
  • [22] Real-time Simulation of Grounding Fault Protection Method Used for Medium-voltage DC Power System Based on RT-LAB
    Fan, Xuexin
    Guo, Penghui
    Ma, Fan
    Wang, Ruitian
    Yang, Guorun
    2018 37TH CHINESE CONTROL CONFERENCE (CCC), 2018, : 5842 - 5847
  • [23] Fault Protection in Medium Voltage DC Microgrids
    Deng, Qiu
    Dougal, Roger A.
    2017 IEEE SECOND INTERNATIONAL CONFERENCE ON DC MICROGRIDS (ICDCM), 2017, : 61 - 68
  • [24] An adaptive hybrid dynamic state estimation method of the medium-voltage DC integrated power system with pulse load
    Xiao, Runlong
    Wang, Gang
    Fu, Lijun
    Ma, Fan
    Li, Chun
    Huang, Renji
    Hao, Xiaoliang
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 134
  • [25] Research on Flexible Medium-voltage DC Distribution Technology Based Shore-to-ship Power Supply System
    Xu, Feng
    Lu, Yi
    Xuan, Xiaohua
    Qiu, Peng
    Tong, Kai
    Xuan, Jiazhuo
    Chen, Qian
    Jiang, Daozhuo
    IECON 2017 - 43RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2017, : 405 - 409
  • [26] A NEW FAULT-INTERRUPTING DEVICE FOR IMPROVED MEDIUM-VOLTAGE SYSTEM AND EQUIPMENT PROTECTION
    GLENN, DJ
    COOK, CJ
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1985, 21 (05) : 1324 - 1332
  • [27] Integrated Protection System Design for Shipboard Power System
    Gong, Yanfeng
    Huang, Yan
    Schulz, Noel N.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2008, 44 (06) : 1930 - 1936
  • [28] Integrated protection system design for shipboard power system
    Gong, YF
    Huang, Y
    Schulz, N
    2005 IEEE Electric Ship Technologies Symposium, 2005, : 237 - 243
  • [29] Fault Diagnosis of Shipboard Medium-Voltage Alternating Current Power System with Fault Recording Data-Driven SE-ResNet18-1 Model
    Peng, Fengjian
    Mu, Longhua
    Fang, Chongkai
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2024, 19 (03) : 403 - 413
  • [30] Fault Detection and Classification in Medium Voltage DC Shipboard Power Systems With Wavelets and Artificial Neural Networks
    Li, Weilin
    Monti, Antonello
    Ponci, Ferdinanda
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2014, 63 (11) : 2651 - 2665