Development of a portable total nitrogen detection system based on microelectrodes

被引:0
|
作者
机构
[1] State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing
[2] University of Chinese Academy of Sciences, Beijing
来源
Bian, C. (cbian@mail.ie.ac.cn) | 1600年 / SAGE Publications Ltd卷 / 228期
关键词
Electrochemical modification; Microelectrode; Nitrogen detection; Portable;
D O I
10.1177/1740349913487520
中图分类号
学科分类号
摘要
This article presents a portable total nitrogen detection system based on microelectrode chip. The microelectrode chip, integrated with a working electrode modified with copper and a counter electrode, was fabricated by microelectromechanical systems technology and was used to detect the concentration of nitrate after total nitrogen digestion. MSP430F4793 microcontroller was applied in this portable system to realize multifunction such as electrochemical modification of the working electrode, detection of the current response, storage of the detection results, calibration, and communication. Water samples from a lake were detected by this developed system, an electrochemical analyzer, and a commercial total nitrogen monitoring system at the same time. Correlation coefficients of 92.9% and 98.15% were shown by the developed system with the electrochemical analyzer and the commercial total nitrogen monitoring system, respectively. Compared with the traditional analyzer system, this portable detection system has the advantages of miniaturization, low cost, and low power consumption. © IMechE 2013.
引用
收藏
页码:46 / 51
页数:5
相关论文
共 50 条
  • [21] A novel portable electrochemiluminescence detection device based on SiPM
    Yu, Changqing
    Wu, Yangbo
    2024 9TH INTERNATIONAL CONFERENCE ON ELECTRONIC TECHNOLOGY AND INFORMATION SCIENCE, ICETIS 2024, 2024, : 104 - 110
  • [22] Portable projection-based AR system
    Oh, Jihyun
    Seo, Byung-Kuk
    Lee, Moon-Hyun
    Park, Hanhoon
    Park, Jong-Il
    ADVANCES IN VISUAL COMPUTING, PROCEEDINGS, PT 2, 2007, 4842 : 742 - 750
  • [23] Evaluation of the efficacy of a portable LIBS system for detection of CWA on surfaces
    D. L’Hermite
    E. Vors
    T. Vercouter
    G. Moutiers
    Environmental Science and Pollution Research, 2016, 23 : 8219 - 8226
  • [24] A Portable Impedance Immunosensing System for Rapid Detection of Salmonella Typhimurium
    Wen, Tao
    Wang, Ronghui
    Sotero, America
    Li, Yanbin
    SENSORS, 2017, 17 (09):
  • [25] Radon fast detection and environmental monitoring with a portable wireless system
    Nodari, Benedetta
    Caldara, Michele
    Re, Valerio
    Fabris, Lorenzo
    2015 6TH IEEE INTERNATIONAL WORKSHOP ON ADVANCES IN SENSORS AND INTERFACES (IWASI), 2015, : 254 - 259
  • [26] Evaluation of the efficacy of a portable LIBS system for detection of CWA on surfaces
    L'Hermite, D.
    Vors, E.
    Vercouter, T.
    Moutiers, G.
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2016, 23 (09) : 8219 - 8226
  • [27] Is a portable accelerometer-based navigation system useful in total hip arthroplasty?: A systematic review and meta-analysis
    Shigemura, Tomonori
    Baba, Yoshihiko
    Murata, Yasuaki
    Yamamoto, Yohei
    Shiratani, Yuki
    Hamano, Hiroyuki
    Wada, Yuichi
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2021, 107 (01)
  • [28] Portable Accelerometer-Based Navigation System for Cup Placement of Total Hip Arthroplasty: A Prospective, Randomized, Controlled Study
    Tanino, Hiromasa
    Nishida, Yasuhiro
    Mitsutake, Ryo
    Ito, Hiroshi
    JOURNAL OF ARTHROPLASTY, 2020, 35 (01) : 172 - 177
  • [29] Development of Glass Microelectrodes Pipette Puller Based on Monitoring and Controlling Heating Strength
    Wang, Yuan
    Fan, Li-Feng
    Wang, Jian-Xu
    Chen, Yang
    Huang, Lan
    Wang, Zhong-Yi
    Computer and Computing Technologies in Agriculture VIII, 2015, 452 : 426 - 436
  • [30] Optimization of acetylcholinesterase immobilization on microelectrodes based on nitrophenyl diazonium for sensitive organophosphate insecticides detection
    Ovidiu Ilie Covaci
    Bogdan Bucur
    Madalina Petruta Bucur
    Gabriel Lucian Radu
    Microchimica Acta, 2010, 169 : 335 - 343