Biomechanical analysis of atlantoaxial intraarticular fusion cages with posterior pedicle screws fixation using finite element method

被引:2
|
作者
Gu Y. [1 ]
He S. [1 ]
Wang Y. [2 ]
Xu D. [2 ]
Ma W. [2 ]
Zhao L. [2 ]
机构
[1] Shanghai Tenth People's Hospital, School of Medicine, Tongji University, 301#, Yanchang Zhong Road, Shanghai City
[2] Ningbo Sixth Hospital, 1059#, Zhongshan Dong Road, Ningbo City, Zhejiang Province
关键词
Atlantoaxial fixation; Atlantoaxial intraarticular fusion cage; Biomechanics; Finite element analysis;
D O I
10.1016/j.clinbiomech.2022.105735
中图分类号
学科分类号
摘要
Background: Cadaveric biomechanical studies indicated that atlantoaxial intraarticular fusion cages with posterior pedicle screws fixation could increase the multi-axial rigidity. However, the stress distribution of the fixation construct is still unclear. Methods: From computed tomography images, a nonlinear intact three-dimensional C0–2 finite element model was developed and validated. Four finite element models were reconstructed: intact model, unstable model, bilateral atlantoaxial pedicle screws combined bilateral cages model, bilateral atlantoaxial pedicle screws model. The range of motion and maximum von Mises stresses were compared under flexion, extension, lateral bending, and axial rotation. Findings: Compared with unstable model, both bilateral atlantoaxial pedicle screws combined bilateral cages model and bilateral atlantoaxial pedicle screws model fixation techniques reduced range of motion by >99% in extension, flexion, lateral bending and axial rotation. For bilateral atlantoaxial pedicle screws combined bilateral cages model, the maximum von Mises stress was in the base of the C2 screw head site. In the bilateral atlantoaxial pedicle screws model was stressed at the rod linked C1 and C2 screws. Compared with bilateral atlantoaxial pedicle screws model, bilateral atlantoaxial pedicle screws combined bilateral cages model reduced the maximum von Mises stress on the implants by >90% in extension, flexion, lateral bending and axial rotation. Interpretation: The finite element model study indicated that, compared with posterior C1-C2 pedicle screws fixation, atlantoaxial intraarticular fusion cages with posterior pedicle screws fixation could not only significantly restore stability to the atlantoaxial junction, but also dramatically reduce the maximum von Mises stress in the C1-C2 pedicle screws. © 2022 Elsevier Ltd
引用
收藏
相关论文
共 50 条
  • [21] Biomechanical comparison of posterior intermediate screw fixation techniques with hybrid monoaxial and polyaxial pedicle screws in the treatment of thoracolumbar burst fracture: a finite element study
    Huan Liu
    Hongwei Wang
    Jun Liu
    Changqing Li
    Yue Zhou
    Liangbi Xiang
    Journal of Orthopaedic Surgery and Research, 14
  • [22] The effect of screw tunnels on the biomechanical stability of vertebral body after pedicle screws removal: a finite element analysis
    Jia-Ming Liu
    Yu Zhang
    Yang Zhou
    Xuan-Yin Chen
    Shan-Hu Huang
    Zi-Kai Hua
    Zhi-Li Liu
    International Orthopaedics, 2017, 41 : 1183 - 1187
  • [23] Biomechanical analysis of cages for posterior lumbar interbody fusion
    Fantigrossi, Alfonso
    Galbusera, Fabio
    Raimondi, Manuela Teresa
    Sassi, Marco
    Fornari, Maurizio
    MEDICAL ENGINEERING & PHYSICS, 2007, 29 (01) : 101 - 109
  • [24] Biomechanical differences between two different shapes of oblique lumbar interbody fusion cages on whether to add posterior internal fixation system: a finite element analysis
    Liu, Jianchao
    Geng, Ziming
    Wang, Jian
    Zhang, Zepei
    Zhang, Xingze
    Miao, Jun
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [25] Decisive factor in increase of loading at adjacent segments after lumbar fusion: operative technique, pedicle screws, or fusion itself. - biomechanical analysis using finite element
    Park, Joon-Hee
    Kim, Ho-Joong
    Kang, Kyoung-Tak
    Kim, Ka-yeon
    Chun, Heoung-Jae
    Moon, Seong-Hwan
    Lee, Hwan-Mo
    FOURTH INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS, 2010, 7522
  • [26] Biomechanical differences between two different shapes of oblique lumbar interbody fusion cages on whether to add posterior internal fixation system: a finite element analysis
    Jianchao Liu
    Ziming Geng
    Jian Wang
    Zepei Zhang
    Xingze Zhang
    Jun Miao
    Journal of Orthopaedic Surgery and Research, 18
  • [27] Biomechanical Evaluation of an Atlantoaxial Lateral Mass Fusion Cage With C1-C2 Pedicle Fixation
    Li, Songkai
    Ni, Bin
    Xie, Ning
    Wang, Mingfei
    Guo, Xiang
    Zhang, Feng
    Wang, Jian
    Zhao, Weidong
    SPINE, 2010, 35 (14) : E624 - E632
  • [28] Biomechanical Effects of Lateral Inclination C1 and C2 Pedicle Screws on Atlantoaxial Fixation
    Zhang, Lei
    Wang, Huan
    ORTHOPAEDIC SURGERY, 2021, 13 (07) : 2027 - 2033
  • [29] Biomechanical Comparison of Posterior Fixation Combinations with an Allograft Spacer between the Lateral Mass and Pedicle Screws
    Lee, Soo-Bin
    Lee, Hwan-Mo
    Park, Tae-Hyun
    Lee, Sung Jae
    Kwon, Young-Woo
    Moon, Seong-Hwan
    Lee, Byung Ho
    APPLIED SCIENCES-BASEL, 2020, 10 (20): : 1 - 12
  • [30] Biomechanical study of tarsometatarsal joint fusion using finite element analysis
    Wang, Yan
    Li, Zengyong
    Zhang, Ming
    MEDICAL ENGINEERING & PHYSICS, 2014, 36 (11) : 1394 - 1400