Assessing the Precision and Accuracy of Foraminifera Elemental Analysis at Low Ratios

被引:0
|
作者
Lu, Wanyi [1 ,2 ]
Guo, Weifu [2 ]
Oppo, Delia W. [2 ]
机构
[1] Tongji Univ, State Key Lab Marine Geol, Shanghai, Peoples R China
[2] Woods Hole Oceanog Inst, Woods Hole, MA 02543 USA
基金
美国国家科学基金会;
关键词
ICP-MS; iCAP Qc; foraminifera; trace element; carbonate; ATLANTIC;
D O I
10.1029/2024GC011560
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
The minor and trace element compositions of biogenic carbonates such as foraminifera are important tools in paleoceanography research. However, most studies have focused primarily on samples with element to calcium (El/Ca) ratios higher than the El/Ca range often found in benthic foraminifera. Here, we systematically assess the precision and accuracy of foraminifera elemental analysis across a wide range of El/Ca especially at relatively low ratios, using a method on a Thermo Scientific iCAP Qc quadrupole Inductively Coupled Plasma Mass Spectrometer (ICP-MS). We focus on two benthic foraminifera species, Hoeglundina elegans and Cibicidoides pachyderma, and prepared a suite of solution standards based on their typical El/Ca ranges to correct for signal drift and matrix effects during ICP-MS analysis and to determine analytical precision. We observe comparable precisions with published studies at high El/Ca, and higher relative standard deviations for each element at lower El/Ca, as expected from counting statistics. The overall long-term analytical precision (2 sigma) of the H. elegans-like consistency standard solutions was 6.5%, 4.6%, 5.0%, for Li/Ca, Mg/Ca, Mg/Li, and 6.4%, 10.0%, 4.2% for B/Ca, Cd/Ca, Sr/Ca. The precision for H. elegans-like Mg/Li is equivalent to a temperature uncertainty of 0.5-1.1 degrees C. Measurement precisions were also assessed based on three international standards (one solution and two powder standards) and replicate measurements of H. elegans and C. pachyderma samples. We provide file templates and program scripts that can be used to design calibration and consistency standards, prepare run sequences, and convert the raw ICP-MS data into molar ratios.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] A Novel Approach to Assessing the Accuracy and Precision of Capillary Collection Devices
    Springer, Lee
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2016, 146
  • [22] ASSESSING PRECISION AND ACCURACY IN BLOOD-GAS PROFICIENCY TESTING
    HANSEN, JE
    CASABURI, R
    CRAPO, RO
    JENSEN, RL
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1990, 141 (05): : 1190 - 1193
  • [23] Assessing precision and accuracy of false-profile hip radiographs
    Li, Ryan T.
    Neral, Mithun
    Gould, Heath
    Hu, Emily
    Liu, Raymond W.
    Salata, Michael J.
    HIP INTERNATIONAL, 2021, 31 (02) : 258 - 263
  • [24] ASSESSING PRECISION AND ACCURACY IN BLOOD-GAS PROFICIENCY TESTING
    RAO, AV
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1992, 145 (02): : 498 - 498
  • [25] Assessing Parent Material Uniformity by Elemental Analysis
    Shinkarev, A. A.
    Kornilova, A. G.
    Lygina, T. Z.
    Giniyatullin, K. G.
    Gilmutdinov, R. R.
    UCHENYE ZAPISKI KAZANSKOGO UNIVERSITETA-SERIYA ESTESTVENNYE NAUKI, 2010, 152 (04): : 78 - 91
  • [27] On the precision and accuracy of impact analysis techniques
    Hattori, Lile
    Guerrero, Dalton
    Figueiredo, Jorge
    Brunet, Joao
    Damasio, Jemerson
    7TH IEEE/ACIS INTERNATIONAL CONFERENCE ON COMPUTER AND INFORMATION SCIENCE IN CONJUNCTION WITH 2ND IEEE/ACIS INTERNATIONAL WORKSHOP ON E-ACTIVITY, PROCEEDINGS, 2008, : 513 - 518
  • [28] PRECISION AND ACCURACY OF RIS-ANALYSIS
    ZILLIACUS, R
    LIKONEN, J
    AUTERINEN, I
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1991, (114): : 279 - 282
  • [29] Precision and accuracy in standards analysis by PIXE
    Waksman, S.Y.
    Pape, A.
    Heitz, C.
    Journal of Radioanalytical and Nuclear Chemistry, 1995, 196 (01): : 135 - 143
  • [30] PRECISION AND ACCURACY OF INFRARED MILK ANALYSIS
    BIGGS, DA
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1972, 55 (03): : 488 - &