A novel integrated lateral flow immunoassay platform for the detection of cardiac troponin I using hierarchical dendritic copper-nickel nanostructures

被引:4
|
作者
Tan, Yuxin [1 ]
Zhang, Shirong [1 ]
Liu, Yilei [1 ]
Li, Jishun [2 ]
Zhang, Shenglan [3 ]
Pan, Hongcheng [1 ,2 ]
机构
[1] Guilin Univ Technol, Coll Chem & Bioengn, Guangxi Key Lab Electrochem & Magnetochem Funct Ma, Guilin 541004, Peoples R China
[2] Guilin Univ Technol, Coll Environm Sci & Engn, Guilin 541004, Peoples R China
[3] Guilin Univ Technol, Coll Mech & Control Engn, Guilin 541004, Peoples R China
基金
中国国家自然科学基金;
关键词
Integrated lateral flow immunoassay; Hierarchical dendritic copper-nickel film; Background fluorescence quenching; Cardiac troponin I; COMSOL multiphysics simulation; IMMUNOCHROMATOGRAPHIC ASSAY; WICKING;
D O I
10.1016/j.talanta.2024.126332
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Cardiac troponin I (cTnI) is a critical biomarker for the diagnosis of acute myocardial infarction (AMI). Herein, we report a novel integrated lateral flow immunoassay (LFIA) platform for highly sensitive point-of-care testing (POCT) of cTnI using hierarchical dendritic copper-nickel (HD-nanoCu-Ni) nanostructures. The electrodeposited HD-nanoCu-Ni film (similar to 22 mu m thick) on an ITO-coated glass substrate exhibits superior capillary action and structural integrity. These properties enable efficient sample transport and antibody immobilization, making it a compelling alternative to conventional multi-component paper-based LFIA test strips, which are often plagued by structural fragility and susceptibility to moisture damage. The biofunctionalized HD-nanoCu-Ni substrates were laser-etched with lateral flow channels, including a sample loading/conjugate release zone, a test zone, and a control zone. Numerical simulations were used to further optimize the design of these channels to achieve optimal fluid flow and target capture. The HD-nanoCu-Ni LFIA device utilizes a fluorescence quenching based sandwich immunoassay format using antibody-labeled gold nanoparticles (AuNPs) as quenchers. Two different fluorescent materials, fluorescein isothiocyanate (FITC) and CdSe@ZnS quantum dots (QDs), were used as background fluorophores in the device. Upon the formation of a sandwich immunocomplex with cTnI on the HDnanoCu-Ni device, introduced AuNPs led to the fluorescence quenching of the background fluorophores. The total assay time was approximately 15 min, demonstrating the rapid and efficient nature of the HD-nanoCu-Ni LFIA platform. For FITC, both inner filter effect (IFE) and fluorescence resonance energy transfer (FRET) contributed to the AuNP-mediated quenching. In the case of CdSe@ZnS QDs, IFE dominated the AuNP-induced quenching. Calibration curves were established based on the relationship between the fluorescence quenching intensity and cTnI concentration in human serum samples, ranging from 0.5 to 128 ng/mL. The limits of detection (LODs) were determined to be 0.27 ng/mL and 0.40 ng/mL for FITC and CdSe@ZnS QDs, respectively. A method comparison study using Passing-Bablok regression analysis on varying cTnI concentrations in human serum samples confirmed the equivalence of the HD-nanoCu-Ni LFIA platform to a commercial fluorescence cTnI LFIA assay kit, with no significant systematic or proportional bias observed.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Sensitive and Quantitative Determination of Cardiac Troponin I Based on Silica-Encapsulated CdSe/ZnS Quantum Dots and a Fluorescence Lateral Flow Immunoassay
    Wu, Min
    Zhang, Xian
    Wu, Ruili
    Wang, Guochun
    Li, Jinjie
    Chai, Yujuan
    Shen, Huaibin
    Li, Lin Song
    ANALYTICAL LETTERS, 2020, 53 (11) : 1757 - 1773
  • [32] Novel electrochemical sensing platform for ultrasensitive detection of cardiac troponin I based on aptamer-MoS2 nanoconjugates
    Qiao, Xiujuan
    Li, Kunxia
    Xu, Jinqiong
    Cheng, Ni
    Sheng, Qinglin
    Cao, Wei
    Yue, Tianli
    Zheng, Jianbin
    BIOSENSORS & BIOELECTRONICS, 2018, 113 : 142 - 147
  • [33] Highly sensitive detection of cardiac troponin I in human serum using gold nanoparticle-based enhanced sandwich immunoassay
    Kim, Wan-Joong
    Cho, Hyo Young
    Kim, Bong Kyu
    Huh, Chul
    Chung, Kwang Hyo
    Ahn, Chang-Geun
    Kim, Young Jun
    Kim, Ansoon
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 221 : 537 - 543
  • [34] Flower-shaped magnetic fluorescent nanoparticles based lateral flow biosensor for highly sensitive detection of cardiac troponin I
    Liu, Guan
    Chen, Mingrui
    Wang, Jiulin
    Cui, Xinyuan
    Wang, Kan
    Yang, Ziyang
    Gao, Ang
    Zhang, Amin
    Zhang, Qian
    Shen, Yulan
    Gao, Guo
    Cui, Daxiang
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 414
  • [35] Optimization of an enzyme linked DNA aptamer assay for cardiac troponin I detection: synchronous multiple sample analysis on an integrated microfluidic platform
    Gopinathan, Priya
    Sinha, Anirban
    Chung, Yi-Da
    Shiesh, Shu-Chu
    Lee, Gwo-Bin
    ANALYST, 2019, 144 (16) : 4943 - 4951
  • [36] Silver-enhanced colloidal gold dip strip immunoassay integrated with smartphone-based colorimetry for sensitive detection of cardiac marker troponin I
    Napakporn Poosinuntakul
    Theerawut Chanmee
    Sureerut Porntadavity
    Orawon Chailapakul
    Amara Apilux
    Scientific Reports, 12
  • [37] Silver-enhanced colloidal gold dip strip immunoassay integrated with smartphone-based colorimetry for sensitive detection of cardiac marker troponin I
    Poosinuntakul, Napakporn
    Chanmee, Theerawut
    Porntadavity, Sureerut
    Chailapakul, Orawon
    Apilux, Amara
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [38] Development and optimization of surface-enhancement Raman scattering-based lateral flow immunoassays for the ultrasensitive detection of cardiac troponin I
    Song, Eunyeong
    Kim, Insu
    Jeon, Changsu
    Pyun, Sunghyun
    MICROCHEMICAL JOURNAL, 2023, 193
  • [39] Dual Colorimetric/Electrochemical Detection of Salmonella typhimurium Using a Laser-Induced Graphene Integrated Lateral Flow Immunoassay Strip
    Preechakasedkit, Pattarachaya
    Panphut, Wattana
    Lomae, Atchara
    Wonsawat, Wanida
    Citterio, Daniel
    Ruecha, Nipapan
    ANALYTICAL CHEMISTRY, 2023, 95 (37) : 13904 - 13912
  • [40] A Novel Paper-plastic Microfluidic Hybrid Chip Integrated with a Lateral Flow Immunoassay for Dengue Nonstructural Protein 1 Antigen Detection