A novel integrated lateral flow immunoassay platform for the detection of cardiac troponin I using hierarchical dendritic copper-nickel nanostructures

被引:4
|
作者
Tan, Yuxin [1 ]
Zhang, Shirong [1 ]
Liu, Yilei [1 ]
Li, Jishun [2 ]
Zhang, Shenglan [3 ]
Pan, Hongcheng [1 ,2 ]
机构
[1] Guilin Univ Technol, Coll Chem & Bioengn, Guangxi Key Lab Electrochem & Magnetochem Funct Ma, Guilin 541004, Peoples R China
[2] Guilin Univ Technol, Coll Environm Sci & Engn, Guilin 541004, Peoples R China
[3] Guilin Univ Technol, Coll Mech & Control Engn, Guilin 541004, Peoples R China
基金
中国国家自然科学基金;
关键词
Integrated lateral flow immunoassay; Hierarchical dendritic copper-nickel film; Background fluorescence quenching; Cardiac troponin I; COMSOL multiphysics simulation; IMMUNOCHROMATOGRAPHIC ASSAY; WICKING;
D O I
10.1016/j.talanta.2024.126332
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Cardiac troponin I (cTnI) is a critical biomarker for the diagnosis of acute myocardial infarction (AMI). Herein, we report a novel integrated lateral flow immunoassay (LFIA) platform for highly sensitive point-of-care testing (POCT) of cTnI using hierarchical dendritic copper-nickel (HD-nanoCu-Ni) nanostructures. The electrodeposited HD-nanoCu-Ni film (similar to 22 mu m thick) on an ITO-coated glass substrate exhibits superior capillary action and structural integrity. These properties enable efficient sample transport and antibody immobilization, making it a compelling alternative to conventional multi-component paper-based LFIA test strips, which are often plagued by structural fragility and susceptibility to moisture damage. The biofunctionalized HD-nanoCu-Ni substrates were laser-etched with lateral flow channels, including a sample loading/conjugate release zone, a test zone, and a control zone. Numerical simulations were used to further optimize the design of these channels to achieve optimal fluid flow and target capture. The HD-nanoCu-Ni LFIA device utilizes a fluorescence quenching based sandwich immunoassay format using antibody-labeled gold nanoparticles (AuNPs) as quenchers. Two different fluorescent materials, fluorescein isothiocyanate (FITC) and CdSe@ZnS quantum dots (QDs), were used as background fluorophores in the device. Upon the formation of a sandwich immunocomplex with cTnI on the HDnanoCu-Ni device, introduced AuNPs led to the fluorescence quenching of the background fluorophores. The total assay time was approximately 15 min, demonstrating the rapid and efficient nature of the HD-nanoCu-Ni LFIA platform. For FITC, both inner filter effect (IFE) and fluorescence resonance energy transfer (FRET) contributed to the AuNP-mediated quenching. In the case of CdSe@ZnS QDs, IFE dominated the AuNP-induced quenching. Calibration curves were established based on the relationship between the fluorescence quenching intensity and cTnI concentration in human serum samples, ranging from 0.5 to 128 ng/mL. The limits of detection (LODs) were determined to be 0.27 ng/mL and 0.40 ng/mL for FITC and CdSe@ZnS QDs, respectively. A method comparison study using Passing-Bablok regression analysis on varying cTnI concentrations in human serum samples confirmed the equivalence of the HD-nanoCu-Ni LFIA platform to a commercial fluorescence cTnI LFIA assay kit, with no significant systematic or proportional bias observed.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] A Fluorescent Lateral Flow Immunoassay for the Detection of Skeletal Muscle Troponin I in Serum for Muscle Injury Monitoring at the Point of Care
    Tang, Deding
    Wu, Shuang
    Kong, Mengqi
    Liu, Zhaonan
    Li, Zonghao
    Han, Ying
    Gong, Yan
    Hu, Jie
    BIOSENSORS-BASEL, 2024, 14 (08):
  • [22] EARLIER DETECTION OF ACUTE MYOCARDIAL INJURY USING A HIGH-SENSITIVITY CARDIAC TROPONIN I IMMUNOASSAY
    Maruta, Toyoaki
    Li, Tian
    Morrissey, Jeremiah
    Blood, Jane
    Macy, Elizabeth
    Bach, Richard
    Townsend, R.
    Boyle, Walter
    CRITICAL CARE MEDICINE, 2012, 40 (12) : U76 - U76
  • [23] Sensitive and quantitative detection of cardiac troponin I with upconverting nanoparticle lateral flow test with minimized interference
    Bayoumy, Sherif
    Martiskainen, Iida
    Heikkila, Taina
    Rautanen, Carita
    Hedberg, Pirjo
    Hyytia, Heidi
    Wittfooth, Saara
    Pettersson, Kim
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [24] Sensitive and quantitative detection of cardiac troponin I with upconverting nanoparticle lateral flow test with minimized interference
    Sherif Bayoumy
    Iida Martiskainen
    Taina Heikkilä
    Carita Rautanen
    Pirjo Hedberg
    Heidi Hyytiä
    Saara Wittfooth
    Kim Pettersson
    Scientific Reports, 11
  • [25] A signal amplifying fluorescent nanoprobe and lateral flow assay for ultrasensitive detection of cardiac biomarker troponin I
    Lou, Doudou
    Fan, Lin
    Ji, Yongxin
    Gu, Ning
    Zhang, Yu
    ANALYTICAL METHODS, 2019, 11 (28) : 3506 - 3513
  • [26] Evaluation of the analytical performance of a new ADVIA immunoassay using the Centaur XPT platform system for the measurement of cardiac troponin I
    Musetti, Veronica
    Masotti, Silvia
    Prontera, Concetta
    Storti, Simona
    Ndreu, Rudina
    Zucchelli, Gian Carlo
    Passino, Claudio
    Emdin, Michele
    Clerico, Aldo
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2018, 56 (09) : E229 - E231
  • [27] Merging Lateral Flow Immunoassay with Electroanalysis as a Novel Sensing Platform: Prostate Specific Antigen Detection as Case of Study
    Miglione, Antonella
    Di Nardo, Fabio
    Cavalera, Simone
    Serra, Thea
    Baggiani, Claudio
    Cinti, Stefano
    Anfossi, Laura
    ANALYTICAL CHEMISTRY, 2024, 96 (06) : 2297 - 2302
  • [28] Time-resolved fluorescence resonance energy transfer-based lateral flow immunoassay using a raspberry-type europium particle and a single membrane for the detection of cardiac troponin I
    Lee, Kyung Won
    Kim, Ka Ram
    Chun, Hyeong Jin
    Jeong, Kwan Young
    Hong, Dong-Ki
    Lee, Kook-Nyung
    Yoon, Hyun C.
    BIOSENSORS & BIOELECTRONICS, 2020, 163
  • [29] A novel fluorescent aptasensor for the highly sensitive and selective detection of cardiac troponin I based on a graphene oxide platform
    Dongkui Liu
    Xing Lu
    Yiwen Yang
    Yunyun Zhai
    Jian Zhang
    Lei Li
    Analytical and Bioanalytical Chemistry, 2018, 410 : 4285 - 4291
  • [30] A novel fluorescent aptasensor for the highly sensitive and selective detection of cardiac troponin I based on a graphene oxide platform
    Liu, Dongkui
    Lu, Xing
    Yang, Yiwen
    Zhai, Yunyun
    Zhang, Jian
    Li, Lei
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (18) : 4285 - 4291