Enhanced capillary pumping performance of flexible heat pipe device with multi cross-section ultra-thin wick

被引:3
作者
Cui, Jiarong [1 ,2 ,3 ]
Xu, Wenjun [1 ,2 ,3 ]
Hu, Zhanpeng [1 ,2 ,3 ]
Jiang, Xiyang [1 ,2 ,3 ]
Ling, Weisong [1 ,2 ,3 ]
Zhou, Wei [1 ,2 ,3 ]
机构
[1] Xiamen Univ, Pen Tung Sah Inst Micronano Sci & Technol, Xiamen 361005, Peoples R China
[2] Xiamen Univ, Dept Mech & Elect Engn, Xiamen 361005, Peoples R China
[3] Xiamen Inst Technol, Higher Educ Key Lab Flexible Mfg Equipment Integra, Xiamen, Peoples R China
基金
中国国家自然科学基金;
关键词
Flexible heat pipe; Capillary pumping performance; Analytical solution; Multi cross-section wick; FABRICATION; OXYGENATOR; SIMULATION; FLUID;
D O I
10.1016/j.icheatmasstransfer.2024.108405
中图分类号
O414.1 [热力学];
学科分类号
摘要
Copper mesh, with its excellent flexibility and thermal conductivity, is an ideal material for the wick of flexible heat pipe. In this paper, a structure optimization strategy of wick with multi cross-section is proposed to enhance its capillary pumping performance. The analytical solution models of single-section and multi cross-section wicks are established by the kinetic equation of capillary pumping. Numerical simulation is used to analyze the capillary pumping performance of the multi cross-section wicks, and the results confirm the multi cross-section enhancement mechanism with the infrared experimental results. Laser processing, sintering and molding, and super-hydrophilic modification are used to fabricate the multi cross-section wick. Laser removal of rectangular units can modulate the capillary pumping performance of the multi cross-section wick. The capillary height h of the multi cross-section wick is enhanced by 13.4 % when the size of the rectangular unit l x w = 40 mm x 1.5 mm and the number of removals N = 5. Compared with the heat transfer performance of the single cross-section flexible heat pipe, the evaporator temperature T and thermal resistance R of the multi cross-section flexible heat pipe decreased by 16.6 % and 77.4 %, respectively. The effective thermal conductivity Keff reaches 10,560 W/ (m & sdot;K), which is 26 times higher than that of copper.
引用
收藏
页数:15
相关论文
共 39 条
[1]   Enhanced capillary and heat transfer performance of asymmetric micropost wicks [J].
Bang, Soosik ;
Kim, Jeonghwan ;
Ryu, Seunggeol ;
Ki, Seokkan ;
Heo, Yun Jung ;
Lee, Choongyeop ;
Nam, Youngsuk .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2023, 146
[2]   Thermal Management of On-Chip Hot Spot [J].
Bar-Cohen, Avram ;
Wang, Peng .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2012, 134 (05)
[3]   Enhanced wickability of single-columnar, non-uniform pore-size wick using Lattice Boltzmann Method [J].
Borumand, Mohammad ;
Lee, Taehun ;
Hwang, Gisuk .
COMPUTERS & FLUIDS, 2022, 238
[4]   Dynamic model of heat and mass transfer in an unsaturated porous wick of capillary pumped loop [J].
Boubaker, Riadh ;
Platel, Vincent ;
Berges, Alexis ;
Bancelin, Mathieu ;
Hannezo, Edouard .
APPLIED THERMAL ENGINEERING, 2015, 76 :1-8
[5]   Influence of microchannel condenser with different change rate of cross-sections along the flow field on the anti-gravity performance of loop heat pipe [J].
Cui, Jiarong ;
Ling, Weisong ;
Zhou, Wei ;
Hu, Zhanpeng ;
Zhu, Yi .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2024, 224
[6]   Numerical investigation of characteristics of wick structure and working fluid of U-shape heat pipe for CPU cooling [J].
Elnaggar, Mohamed H. A. .
MICROELECTRONICS RELIABILITY, 2014, 54 (01) :297-302
[7]   Predicting membrane oxygenator pressure drop using computational fluid dynamics [J].
Gage, KL ;
Gartner, MJ ;
Burgreen, GW ;
Wagner, WR .
ARTIFICIAL ORGANS, 2002, 26 (07) :600-607
[8]   Design, fabrication and performance tests for a polymer-based flexible flat heat pipe [J].
Hsieh, Shou-Shing ;
Yang, Ya-Ru .
ENERGY CONVERSION AND MANAGEMENT, 2013, 70 :10-19
[9]   Biomimetic porous wick with efficient fluid transport and excellent heat transfer for loop heat pipes [J].
Hu, Xianfeng ;
Hu, Chengzhi ;
Chen, Sizhou ;
He, Yichuan ;
Li, Lin ;
Tang, Dawei .
APPLIED THERMAL ENGINEERING, 2024, 249
[10]   Simulation examining the factors influencing capillary wick transport in a refrigerant direct cooling system for power battery packs [J].
Hu, Yun ;
Shan, Fengwu ;
Zeng, Jianbang ;
Liu, Shaohuan ;
Xing, Zhengyuan ;
Fu, Wenxiang ;
Luo, Yufeng .
SCIENTIFIC REPORTS, 2023, 13 (01)