The effect of laser surface texturing on ZnO/MWCNT nanocomposite modified screen-printed carbon electrode for non-enzymatic glucose biosensor

被引:2
|
作者
Jazi, Hamidreza Kaviani [1 ]
Sarafbidabad, Mohsen [1 ]
Ben Henda, Mouna [2 ]
Ahmadipour, Mohsen [3 ]
机构
[1] Univ Isfahan, Fac Engn, Dept Biomed Engn, Esfahan, Iran
[2] Majmaah Univ, Coll Sci, Dept Phys, Al Majmaah 11952, Saudi Arabia
[3] Univ Tenaga Nas, Inst Power Engn, Serdang, Malaysia
关键词
Biosensor; Non-enzymatic; Nanocomposite; Laser; Screen-printed electrode; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; CHEMICALLY-MODIFIED ELECTRODES; ZINC-OXIDE NANOPARTICLES; GLASS THIN-FILM; SENSOR; NANOMATERIALS; NANOTUBES; FABRICATION; ACTIVATION; OXIDATION;
D O I
10.1016/j.diamond.2024.111845
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A novel platform was proposed for the development of glucose biosensors, focusing on an innovative fabrication process based on simple surface modification techniques and non-enzymatic catalytic materials. The platform aimed to enhance biomolecule detection by utilizing a disposable and portable electrode design. Specifically, a screen-printed carbon electrode (SPCE) was selected as the base, and its carbon substrate was engraved using a pulsed fiber laser. Consequently, multi-walled carbon nanotubes (MWCNT) and zinc oxide (ZnO) nanoparticles were deposited on the surface of the laser-engraved screen-printed carbon electrode (LSPCE) using drop-casting and radio frequency (RF) sputtering techniques, respectively. The surface morphology and electrochemical performance of the modified electrodes was thoroughly characterized using field emission scanning electron microscopy (FESEM) and energy dispersive X-ray analysis (EDAX) electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The ZnO/MWCNT nanocomposite was successfully applied to the LSPCE electrode surface, creating a porous spongy structure with mesopores in the 2-50 nm range. The ZnO/MWCNT/LSPCE exhibited high electrocatalytic activity for glucose oxidation when tested in phosphate-buffered saline (PBS) solution with a pH of 7.4. The developed glucose biosensor demonstrated a linear detection range from 1 to 10 mM of glucose with a sensitivity of 0.068 mu A mM- 1 and a detection limit of 0.43 mM. These findings indicate that the ZnO/MWCNT/LSPCE biosensor exhibits high performance in glucose detection, making it a promising candidate for practical applications in glucose monitoring.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Screen printed carbon electrode modified with WS2 nanosheet incorporated with cobalt oxide for non-enzymatic detection of lactic acid
    Jeevanandham, Gayathri
    Kuppuswamy, Guru Prasad
    Sesu, Divya Catherin
    Vediappan, Kumaran
    SURFACES AND INTERFACES, 2023, 40
  • [32] Rapid Determination of Hydrogen Peroxide in Milk with Non-enzymatic Amperometric Sensor Based on Porous Gold Modified Screen-printed Electrode in Online Dialysis System
    Maksuk, Chakkarin
    Tinala, Chonnatee
    Somboot, Wasin
    Jakmunee, Jaroon
    Marken, Frank
    Kanyanee, Tinakorn
    ELECTROANALYSIS, 2023, 35 (02)
  • [33] MIL-88B(Fe) MOF modified screen-printed electrodes for non-enzymatic electrochemical sensing of malathion
    Janjani, Prachi
    Bhardwaj, Upasana
    Agarwal, Madhu
    Gupta, Ragini
    Kushwaha, Himmat Singh
    ENVIRONMENTAL TECHNOLOGY, 2024, 45 (13) : 2649 - 2659
  • [34] Bimetallic Mn/Fe MOF modified screen-printed electrodes for non-enzymatic electrochemical sensing of organophosphate
    Janjani, Prachi
    Bhardwaj, Upasana
    Gupta, Ragini
    Kushwaha, Himmat Singh
    ANALYTICA CHIMICA ACTA, 2022, 1202
  • [35] Ferrocene Decorated N-doped Carbon Modified Electrode with Enhanced Electrocatalytic Activity Towards Non-enzymatic Glucose Detection
    Mathi, Selvam
    Karthikeyan, Venkatraman
    Jayabharathi, Jayaraman
    ELECTROANALYSIS, 2022, 34 (05) : 820 - 829
  • [36] A non-enzymatic glucose amperometric biosensor based on a simple one-step electrodeposition of Cu microdendrites onto single-walled carbon nanohorn-modified electrode
    Zhao, Shuang
    Wang, Tingting
    Wang, Liangliang
    Xu, Shukun
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2015, 19 (03) : 831 - 839
  • [37] An electrochemical biosensor for 3-hydroxybutyrate detection based on screen-printed electrode modified by coenzyme functionalized carbon nanotubes
    Fahimeh Khorsand
    Maedeh Darziani Azizi
    Ali Naeemy
    Bagher Larijani
    Kobra Omidfar
    Molecular Biology Reports, 2013, 40 : 2327 - 2334
  • [38] A Well-Dispersed Pt/Ni/TiO2 Nanotubes Modified Electrode as an Amperometric Non-Enzymatic Glucose Biosensor
    Mahshid, Sahar Sadat
    Luo, Shenglian
    Yang, Lixia
    Mahshid, Sara
    Dolati, Abolghasem
    Ghorbani, Mohammad
    Cai, Qingyun
    SENSOR LETTERS, 2011, 9 (05) : 1598 - 1605
  • [39] Polyaniline/Cerium Oxide Hybrid Modified Carbon Paste Electrode for Non-Enzymatic Glucose Detection
    Zhang, Jie
    Guan, Panpan
    Li, Yongjian
    Li, Wei
    Guo, Qingping
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2016, 37 (07): : 985 - 986
  • [40] A non-enzymatic glucose sensor based on CuO-nanostructure modified carbon ceramic electrode
    Rahim, Abdur
    Rehman, Zia Ur
    Mir, Sadullah
    Muhammad, Nawshad
    Rehman, Fozia
    Nawaz, Mian Hasnain
    Yaqub, Mustansara
    Siddiqi, Saadat Anwar
    Chaudhry, Aqif Anwar
    JOURNAL OF MOLECULAR LIQUIDS, 2017, 248 : 425 - 431