Comparative analysis of transient thermal behaviour and efficiency in longitudinal metal porous fin with combined heat and mass transfer under dehumidification conditions

被引:1
作者
Kumar, P. L. Pavan [1 ]
Gireesha, B. J. [1 ]
Venkatesh, P. [2 ]
Keerthi, M. L. [3 ]
机构
[1] Kuvempu Univ, Dept PG Studies & Res Math, Shivamogga 577451, Karnataka, India
[2] Kuvempu Univ, Sahyadri Sci Coll, Dept Math, Shankaraghatta, Karnataka, India
[3] JNN Coll Engn, Dept Math, Shivamogga, India
关键词
Heat and mass transfer; Unsteady; Dehumidification; Relative humidity; Metal fin; Longitudinal porous fin; DIFFERENT SECTION SHAPES; TEMPERATURE-DEPENDENT PROPERTIES; REFRIGERATION EFFICIENCY; OPTIMIZATION ANALYSIS; DECOMPOSITION METHOD; NATURAL-CONVECTION; RECTANGULAR FIN; PERFORMANCE; AIR; DESIGN;
D O I
10.1016/j.applthermaleng.2024.125069
中图分类号
O414.1 [热力学];
学科分类号
摘要
This investigation explores the transient thermal characteristics of longitudinal porous fins made of Aluminium (Al) and Copper (Cu), exposed to a dynamic moist airstream under dehumidification conditions. Heat and mass transfer processes are initiated when the fin surface temperature falls below the dew point temperature of the surrounding air, driven by differences in temperature and humidity ratios. Heat transfer within the porous structure is modelled using temperature-dependent convective coefficients and Darcy's flow model, with the governing nonlinear partial differential equation transformed into dimensionless form and solved using the Finite Difference Method (FDM) to analyse the fin thermal profile and efficiency over time. These results reveal that Cu fin due to their superior thermal conductivity exhibit higher temperature profile and efficiency compared to Al fin across all pertinent parameters. A key finding is the significant impact of Relative Humidity (RH) on the thermal behaviour of the fin: as RH increases by 400%, the temperature distribution from base to tip decreases by 138% in Al due to its higher specific heat capacity, which enables it to absorb more latent heat and 85% in Cu, where the superior thermal conductivity allows for faster heat dissipation. As Darcy number (Da) decreases by 99%, the temperature distribution along the fin from base to tip increases by 0.058% in Al due to its lower thermal conductivity and 0.041% in Cu, where its higher thermal conductivity enables more efficient heat dispersion. These insights are pivotal for advancing fin design and optimization, facilitating improved thermal management in industrial applications under transient and dehumidifying conditions.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Dehumidification-driven efficiency and thermal performance of porous wavy metallic fin: A comparative study of copper and aluminium
    Kumar, P. L. Pavan
    Gireesha, B. J.
    Venkatesh, P.
    APPLIED THERMAL ENGINEERING, 2025, 272
  • [2] Experimental visualization and analysis of transient heat and mass transfer during natural dehumidification of air around square finned tubes under various operating conditions
    Ahmadi, Behrooz
    Arasteh, Hossein
    Yaghoubi, Mahmoud
    Rahbari, Alireza
    ENERGY CONVERSION AND MANAGEMENT, 2022, 255
  • [3] Thermal analysis of a constructal T-shaped porous fin with simultaneous heat and mass transfer
    Hazarika, Saheera Azmi
    Deshamukhya, Tuhin
    Bhanja, Dipankar
    Nath, Sujit
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2017, 25 (09) : 1121 - 1136
  • [4] Analysis of heat transfer through different profiled longitudinal porous fin by differential transformation method
    Sowmya, G.
    Gireesha, Bijjanal Jayanna
    HEAT TRANSFER, 2022, 51 (02) : 2165 - 2180
  • [5] Comparative analysis of thermal behaviour in functionally graded material fin under convective-radiative heat transfer: Homotopy perturbation method
    Kumar, P. L. Pavan
    Gireesha, B. J.
    Venkatesh, P.
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 155
  • [6] 2-D Numerical Analysis of fin efficiency on Straight Rectangular Fin with Combined Heat and Mass Transfer
    Mao, Jin Feng
    Wang, Bo
    Geng, Shi Bin
    Sui, Lu Yan
    VIBRATION, STRUCTURAL ENGINEERING AND MEASUREMENT I, PTS 1-3, 2012, 105-107 : 2117 - 2120
  • [7] Numerical analysis of heat and mass transfer in a compact finned tubes air heat exchanger under dehumidification conditions
    Benelmir, Riad
    Mokraoui, Salim
    HEAT AND MASS TRANSFER, 2012, 48 (04) : 663 - 682
  • [8] A two-dimensional fin efficiency analysis of combined heat and mass transfer in elliptic fins
    Lin, CN
    Jang, JY
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2002, 45 (18) : 3839 - 3847
  • [9] Combined heat and mass transfer analysis for LiCl dehumidification process in a plate type heat exchanger
    Lee, Jae Hyun
    Ro, Gu Hyun
    Kang, Yong Tae
    Chang, Young Soo
    Kim, Seon Chang
    Kim, Young Lyoul
    APPLIED THERMAL ENGINEERING, 2016, 96 : 250 - 257
  • [10] Stretching/shrinking impact on the transient heat transfer in a radial moving porous fin of a longitudinal trapezoidal structure
    Swetha, D. S.
    Madhura, K. R.
    NUMERICAL HEAT TRANSFER PART B-FUNDAMENTALS, 2023, : 1641 - 1653