Finite element analysis of the biomechanical effects of PEEK dental implants on the peri-implant bone

被引:0
|
作者
Department of Dental Materials and Biomaterial Research, School of Dentistry, Charité-University Medicine, Berlin, Germany [1 ]
不详 [2 ]
机构
来源
J. Biomech. | / 1卷 / 1-7期
关键词
Engineering Village;
D O I
暂无
中图分类号
学科分类号
摘要
Biomechanical behavior - Biomechanical effects - Carbon fiber reinforced - Endolign - Minimum safety factor - Optimal stress distribution - Peri-implant bones - Potential problems
引用
收藏
相关论文
共 50 条
  • [31] Stability of the Implant-Alveolar Bone Complex According to the Peri-Implant Bone Loss and Bone Quality: A Finite Element Analysis Study
    Yoon, Youngjae
    Kim, Jae-Eun
    Kim, Eunji
    Park, Soyeon
    Kang, Inyeong
    Kwon, Yong-Dae
    APPLIED SCIENCES-BASEL, 2024, 14 (24):
  • [32] EFFECTS OF DENTAL IMPLANT LENGTH AND BONE QUALITY ON BIOMECHANICAL RESPONSES IN BONE AROUND IMPLANTS: A 3-D NON-LINEAR FINITE ELEMENT ANALYSIS
    Lin, Chun-Li
    Kuo, Yu-Chan
    Lin, Ting-Sheng
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2005, 17 (01): : 44 - 49
  • [33] The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis
    Sugiura, Tsutomu
    Yamamoto, Kazuhiko
    Horita, Satoshi
    Murakami, Kazuhiro
    Tsutsumi, Sadami
    Kirita, Tadaaki
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2016, 46 (03): : 152 - 165
  • [34] Finite Element Analysis (FEA) for Influence of Variation in Dental Implant Dimensions (Length and Diameter) on Peri-implant Bone Stress/Strain Distribution: A Systematic Review
    Sayed, Arshad Jamal
    Mohsin, Syed Fareed
    Garg, Kamlesh Kumar
    Agwan, Muhammad Atif Saleem
    Tareen, Sabahat Ullah Khan
    Alruthea, Mohammed Sulaiman
    Mohan, Sasankoti
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2025, 41 (01) : 318 - 330
  • [35] The effect of diameter, length and elastic modulus of a dental implant on stress and strain levels in peri-implant bone: A 3D finite element analysis
    Robau-Porrua, Amanda
    Perez-Rodriguez, Yoan
    Soris-Rodriguez, Laura M.
    Perez-Acosta, Osmel
    Gonzalez, Jesus E.
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2020, 30 (5-6) : 541 - 558
  • [36] Dental implants in reconstructed jaws: Implant longevity and peri-implant tissue outcomes
    Cheung, LK
    Leung, ACF
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2003, 61 (11) : 1263 - 1274
  • [37] Biomechanical evaluation of stress distributions at the implant-abutment complex and peri-implant bone around mandibular dental implants with different neck geometries and inclinations
    Dinc, Murat M.
    Turkoglu, Pinar
    Selvi, Firat
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2021, 235 (09) : 1035 - 1045
  • [38] Peri-Implant bone response around porous-surface dental implants: A preclinical meta-analysis
    Ahmed, Abeer
    Al-Rasheed, Abdulaziz
    Badwelan, Mohammed
    Alghamdi, Hamdan S.
    SAUDI DENTAL JOURNAL, 2021, 33 (05) : 239 - 247
  • [39] Effect of crown-to-implant ratio on peri-implant stress: A finite element analysis
    Verri, Fellippo Ramos
    de Souza Batista, Victor Eduardo
    Santiago, Joel Ferreira, Jr.
    de Faria Almeida, Daniel Augusto
    Pellizzer, Eduardo Piza
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 45 : 234 - 240
  • [40] Histologic and Histomorphometric Analyses of Peri-implant Bone from Loaded Dental Implants: A Case Report
    Chiou, Lan-Lin
    Tanaka, Yoshiatsu
    Iwanaga, Joe
    Tubbs, R. Shane
    Blanchard, Steven
    Hamada, Yusuke
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2023, 43 (03) : 371 - 377