The influence of simulated worn shoe and foot inversion on heel internal biomechanics during running impact: A subject-specific finite element analysis

被引:13
作者
Song, Yang [1 ]
Cen, Xuanzhen [2 ]
Wang, Meizi [1 ,2 ]
Balint, Kovacs [2 ,3 ]
Tan, Qitao [1 ]
Sun, Dong [2 ]
Gao, Shunxiang [2 ]
Li, Fengping [2 ]
Gu, Yaodong [2 ]
Wang, Yan [1 ]
Zhang, Ming [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Biomed Engn, Hong Kong, Peoples R China
[2] Ningbo Univ, Fac Sports Sci, Ningbo, Peoples R China
[3] Hungarian Univ Sports Sci, Dept Kinesiol, Budapest, Hungary
关键词
Running; Worn footwear; Foot inversion; Foot biomechanics; Finite element analysis; PLANTAR PRESSURE; PATTERNS; RUNNERS; STRIKE; RISK;
D O I
10.1016/j.jbiomech.2025.112517
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This study explored how systematic changes in running shoe degradation and foot inversion alter the distribution and peak value of heel pressure and calcaneus stress, as well as the total stress-concentration exposure (TSCE) within the calcaneal bone. A foot-shoe finite element model was employed and three shoe wear conditions (new shoe (CON), moderate worn shoe (MWSC), excessive worn shoe (EWSC)) coupled with three foot inversion angles (0 degrees, 10 degrees, 20 degrees) were further modulated. Simulations were conducted at the impact peak instant during running. Compared to CON0, heel pressure during neutral landings shifted medially and increased with progressive shoe wear, peaking under EWSC0. This shift expanded the high-pressure area by 1.333 cm2 and raised peak pressure by 24.42 %. Foot inversion landings exhibited an opposite trend: increased shoe wear promoted balanced pressure distribution, centralizing the load and eliminating high-pressure areas under EWSC10, where peak pressure was 11.36 % lower than CON10. Calcaneus stress during neutral landings, initially concentrated on the medial calcaneal surface and inferior tuberosity, intensified with wear, expanding high-stress area by 5.276 cm2 and increasing peak stress by 22.79 % under EWSC0. For foot inversion, the high-stress region shifted to the inferior tuberosity, with wear reducing peak stress by 10.41 % and eliminating high-stress area in EWSC10 compared to CON10. TSCE analysis revealed that EWSC10 had the lowest stress exposure (0 %kPa) across all conditions. Worn-out shoes would exacerbate heel internal biomechanics, while these effects may be mitigated by foot inversion, likely due to the formation of a relatively flat and larger contact area between the lateral sole and the ground.
引用
收藏
页数:9
相关论文
共 44 条
[41]   Finite element analysis of subtalar joint arthroereisis on adult-acquired flexible flatfoot deformity using customised sinus tarsi implant [J].
Wong, Duo Wai-Chi ;
Wang, Yan ;
Niu, Wenxin ;
Zhang, Ming .
JOURNAL OF ORTHOPAEDIC TRANSLATION, 2021, 27 :139-145
[42]   Functional restoration and risk of non-union of the first metatarsocuneiform arthrodesis for hallux valgus: A finite element approach [J].
Wong, Duo Wai-Chi ;
Wang, Yan ;
Zhang, Ming ;
Leung, Aaron Kam-Lun .
JOURNAL OF BIOMECHANICS, 2015, 48 (12) :3142-3148
[43]   Design feature combinations effects of running shoe on plantar pressure during heel landing: A finite element analysis with Taguchi optimization approach [J].
Yang, Zihan ;
Cui, Chuyi ;
Wan, Xianglin ;
Zheng, Zhiyi ;
Yan, Songhua ;
Liu, Hui ;
Qu, Feng ;
Zhang, Kuan .
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
[44]   Effects of different contact angles during forefoot running on the stresses of the foot bones: a finite element simulation study [J].
Zhou, Huiyu ;
Xu, Datao ;
Quan, Wenjing ;
Ugbolue, Ukadike Chris ;
Gu, Yaodong .
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12