Investigation on ultimate capacity of built-up columns with double channel sections under axial compression

被引:0
作者
机构
[1] Department of Building Engineering, Tongji University, Shanghai
来源
Li, Yuanqi (liyq@tongji.edu.cn) | 1600年 / Science Press卷 / 35期
关键词
Axial compression; Buckling behaviors; Buckling strength; Built-up column; Built-up section; Cold-formed thin-walled steel;
D O I
10.14006/j.jzjgxb.2014.12.014
中图分类号
学科分类号
摘要
Built-up section members have been widely used in cold-formed thin-walled steel structures, but nowadays design methods for load-carrying capacity provided in related specifications in China are rather rough. The existing axial compression tests on lipped channel section members and built-up box section members, which are composed of lipped channel section members by self-drilling screws, are briefly introduced. The structural behaviors differences of built-up members and individual members were studied through existing experimental data, numerical analysis and theoretical studies. Then, the effects of installation errors and fastener spacing on built-up members' ultimate capacity were studied. Finally, a design method for built-up members with box and I sections under axial compression was proposed based on the above analysis. It can be concluded from this research that built-up box section member's global and distortional buckling strength and built-up I section member's global buckling strength are higher than corresponding single section member's strength, and the existing test results can verify the reasonability of the proposed design method. ©, 2014, Science Press. All right reserved.
引用
收藏
页码:104 / 113
页数:9
相关论文
共 19 条
  • [11] Gardner L., Nethercot D., Numerical modeling of stainless steel structural components: a consistent approach, Journal of Structural Engineering, ASCE, 130, 10, pp. 1586-1601, (2004)
  • [12] Ellobody E., Young B., Structural performance of cold-formed high strength stainless steel columns, Journal of Constructional Steel Research, 61, 12, pp. 1631-1649, (2005)
  • [13] Schafer B.W., Local, distortional and Euler buckling of thin-walled columns, Journal of Structural Engineering, ASCE, 128, 3, pp. 289-299, (2002)
  • [14] Atle G., Stability of built-up columns, Journal of Engineering Mechanics, ASCE, 117, 6, pp. 1331-1345, (1991)
  • [15] Liu H., Compression tests and theoretical research of open section built-up cold-formed steel stub columns, pp. 10-28, (2010)
  • [16] AS/NZS No. 4600: 2005 Cold-formed steel structures, (2005)
  • [17] Thomasson P., Thin-walled C-shaped panels in axial compression, Journal of Structural Engineering, ASCE, 116, 5, pp. 1230-1246, (1978)
  • [18] Yang X., Yao J., Experimental study and finite element analysis on cold-formed channel columns with connecting bars between lips, Bulletin of Science and Technology, 23, 5, pp. 729-935, (2007)
  • [19] Li Y., Liu X., Shen Z., Et al., Experimental study on distortional buckling control for high-strength cold-for med thin-walled steel lipped channel columns subject to axial compression, Journal of Building Structures, 31, 11, pp. 10-16, (2010)