Fixation of femoral neck fractures using divergent versus parallel cannulated screws

被引:2
|
作者
Papanastassiou I.D. [1 ,2 ]
Mavrogenis A.F. [2 ]
Kokkalis Z.T. [2 ]
Nikolopoulos K. [2 ]
Skourtas K. [1 ]
Papagelopoulos P.J. [2 ]
机构
[1] First Department of Orthopedics, KAT Hospital, Athens
[2] First Department of Orthopedics, Athens University Medical School, Athens
关键词
Cannulated screws; Divergent; Femoral neck fractures; Internal fixation; Parallel; Stainless steel;
D O I
10.1615/JLongTermEffMedImplants.v21.i1.50
中图分类号
学科分类号
摘要
Controversy exists regarding the optimal method of internal fixation in femoral neck fractures. Biomechanical data suggest that calcar fixation is superior to central screws placement. We propose a divergent technique for placing 3 cannulated stainless steel screws engaging the calcar femorale. Fiftytwo patients admitted to our institution for a femoral neck fracture were treated with the divergent screw technique, over a 7-year period. Four patients were deceased and 4 were lost to follow-up. Of the remaining 44 patients there were 10 males and 34 females, aged from 33 to 78 years (mean, 58 years). All patients were operated on by the same surgeon and were followed-up for a minimum of 2 years (mean: 33.6 months, range: 2-6 years). Twenty-four patients sustained a non-displaced fracture (Garden I-II) and 20 sustained a displaced fracture (Garden III-IV) of the femoral neck. Mean Harris hip score (HHS) was 89.6 points. Avascular necrosis was evident in 4 patients (9%) with displaced fractures. Non-unions or failed internal fixations were not encountered. There was a significant difference in the HHS, in favor of the divergent group (P = 0.006), while more complications were encountered in the parallel group including 6 cases with non-union. In conclusion, parallel screw placement is not critical for an excellent clinical outcome. Our proposed fixation method using 3 screws that diverge and lie in diff erent coronal planes (1 engaging the calcar femorale) with a free-hand technique may off er enhanced fixation. Biomechanical data along with larger clinical studies are needed to establish our proposed method. © 2011 by Begell House, Inc.
引用
收藏
页码:63 / 69
页数:6
相关论文
共 50 条
  • [41] Comparison of femoral neck system versus cannulated cancellous screws for the fixation of femoral neck fracture: a single-center retrospective cohort study
    Caldaria, A.
    Gambuti, E.
    Biagi, N.
    Spadoni, E.
    Saracco, A.
    Massari, L.
    Caruso, G.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, : 3207 - 3213
  • [42] Comparison of Early Clinical Results for Femoral Neck System and Cannulated Screws in the Treatment of Unstable Femoral Neck Fractures
    Zhou, Xiao-Qiang
    Li, Zhi-Qiang
    Xu, Ren-Jie
    She, Yuan-Shi
    Zhang, Xiang-Xin
    Chen, Guang-Xiang
    Yu, Xiao
    ORTHOPAEDIC SURGERY, 2021, 13 (06) : 1802 - 1809
  • [43] Fixation of femoral neck fractures with three screws: results and complications
    Seyfettinoglu, Firat
    Ersan, Onder
    Kovalak, Emrah
    Duygun, Fatih
    Ozsar, Baris
    Ates, Yalim
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2011, 45 (01) : 6 - 13
  • [44] Comparison of femoral neck shortening after femoral neck system and cannulated cancellous screw fixation for displaced femoral neck fractures in young adults
    Zheng, Shunze
    Lin, Dongze
    Chen, Peisheng
    Lin, Chaohui
    Chen, Bin
    Zheng, Ke
    Lin, Fengfei
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (06):
  • [45] Low avascular necrosis rates in femoral neck fractures: efficacy of cannulated screw fixation
    Scattergood, S. D.
    Berry, A. L.
    Flannery, O.
    Burdon, A.
    Mitchell, S. R.
    Fletcher, J. W. A.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 34 (05): : 2565 - 2571
  • [46] Biomechanical Evaluation of the Femoral Neck System in Unstable Pauwels III Femoral Neck Fractures: A Comparison with the Dynamic Hip Screw and Cannulated Screws
    Stoffel, Karl
    Zderic, Ivan
    Gras, Florian
    Sommer, Christoph
    Eberli, Ursula
    Mueller, David
    Oswald, Martin
    Gueorguiev, Boyko
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2017, 31 (03) : 131 - 137
  • [47] Dynamic Hip and Cannulated Screws in Fixation of Adults Femoral Neck Fracture: A Comparative Study
    Al-Kelabi, Adnan Essa
    Mahmoud, Mustafa Shakir
    INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2018, 7 (03): : 135 - 142
  • [48] Biomechanical Evaluation of the Modified Cannulated Screws Fixation of Unstable Femoral Neck Fracture with Comminuted Posteromedial Cortex
    Liu, Jingwen
    Zhang, Baokun
    Yin, Bohao
    Chen, Hongchi
    Sun, Hui
    Zhang, Wei
    BIOMED RESEARCH INTERNATIONAL, 2019, 2019
  • [49] Biomechanical comparison of locking femoral neck plate versus cannulated screws with or without a medial buttress plate in Pauwels type 3 femoral neck fractures
    Onder, Yilmaz
    Bulut, Tugrul
    Eroglu, Osman Nuri
    Ciklacandir, Samet
    Isler, Yalcin
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2024, 58 (06)
  • [50] Comparison Between Femoral Neck Systems and Cannulated Cancellous Screws in Treating Femoral Neck Fractures: A Meta-Analysis
    Tian, Peng
    Kuang, Lan
    Li, Zhi-jun
    Xu, Gui-jun
    Fu, Xin
    GERIATRIC ORTHOPAEDIC SURGERY & REHABILITATION, 2022, 13