Fixation of femoral neck fractures using divergent versus parallel cannulated screws

被引:2
|
作者
Papanastassiou I.D. [1 ,2 ]
Mavrogenis A.F. [2 ]
Kokkalis Z.T. [2 ]
Nikolopoulos K. [2 ]
Skourtas K. [1 ]
Papagelopoulos P.J. [2 ]
机构
[1] First Department of Orthopedics, KAT Hospital, Athens
[2] First Department of Orthopedics, Athens University Medical School, Athens
关键词
Cannulated screws; Divergent; Femoral neck fractures; Internal fixation; Parallel; Stainless steel;
D O I
10.1615/JLongTermEffMedImplants.v21.i1.50
中图分类号
学科分类号
摘要
Controversy exists regarding the optimal method of internal fixation in femoral neck fractures. Biomechanical data suggest that calcar fixation is superior to central screws placement. We propose a divergent technique for placing 3 cannulated stainless steel screws engaging the calcar femorale. Fiftytwo patients admitted to our institution for a femoral neck fracture were treated with the divergent screw technique, over a 7-year period. Four patients were deceased and 4 were lost to follow-up. Of the remaining 44 patients there were 10 males and 34 females, aged from 33 to 78 years (mean, 58 years). All patients were operated on by the same surgeon and were followed-up for a minimum of 2 years (mean: 33.6 months, range: 2-6 years). Twenty-four patients sustained a non-displaced fracture (Garden I-II) and 20 sustained a displaced fracture (Garden III-IV) of the femoral neck. Mean Harris hip score (HHS) was 89.6 points. Avascular necrosis was evident in 4 patients (9%) with displaced fractures. Non-unions or failed internal fixations were not encountered. There was a significant difference in the HHS, in favor of the divergent group (P = 0.006), while more complications were encountered in the parallel group including 6 cases with non-union. In conclusion, parallel screw placement is not critical for an excellent clinical outcome. Our proposed fixation method using 3 screws that diverge and lie in diff erent coronal planes (1 engaging the calcar femorale) with a free-hand technique may off er enhanced fixation. Biomechanical data along with larger clinical studies are needed to establish our proposed method. © 2011 by Begell House, Inc.
引用
收藏
页码:63 / 69
页数:6
相关论文
共 50 条
  • [21] Clinical outcome of femoral neck system versus cannulated compression screws for fixation of femoral neck fracture in younger patients
    Huaijian Hu
    Jingbo Cheng
    Mingli Feng
    Zhihua Gao
    Jingwei Wu
    Shibao Lu
    Journal of Orthopaedic Surgery and Research, 16
  • [22] Cannulated versus non-cannulated cancellous screw fixation for femoral neck fractures: a synthetic bone biomechanical study
    Gardner, A. W.
    Toh, M. Z.
    Yew, K. S. A.
    Lie, D. T. T.
    Chou, S. M.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2015, 23 (01) : 41 - 46
  • [23] Proximal Femoral Locking Plate With Cannulated Screws for the Treatment of Femoral Neck Fractures
    Lin, Dasheng
    Lian, Kejian
    Ding, Zhenqi
    Zhai, Wenliang
    Hong, Jiayuan
    ORTHOPEDICS, 2012, 35 (01) : E1 - E5
  • [24] A Comparative Biomechanical Analysis of Fixation Devices for Unstable Femoral Neck Fractures: The Intertan Versus Cannulated Screws or a Dynamic Hip Screw
    Rupprecht, Martin
    Grossterlinden, Lars
    Ruecker, Andreas H.
    de Oliveira, Alexander Novo
    Sellenschloh, Kay
    Nuechtern, Jakob
    Pueschel, Klaus
    Morlock, Michael
    Rueger, Johannes Maria
    Lehmann, Wolfgang
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 71 (03): : 625 - 634
  • [25] A Comparative Analysis of Femoral Neck System and Three Cannulated Screws Fixation in the Treatment of Femoral Neck Fractures: A Six-Month Follow-Up
    Zhang, Ya-zhong
    Lin, Yan
    Li, Chao
    Yue, Xi-jun
    Li, Gao-yu
    Wang, Bin
    Wang, Yun-qing
    Zhu, Zi-qiang
    ORTHOPAEDIC SURGERY, 2022, 14 (04) : 686 - 693
  • [26] A new angle and its relationship with early fixation failure of femoral neck fractures treated with three cannulated compression screws
    Zhang, Y. L.
    Zhang, W.
    Zhang, C. Q.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (02) : 229 - 234
  • [27] Comparison of femoral neck system versus cannulated screws for treatment of femoral neck fractures: a systematic review and meta-analysis
    Jiang, Jiabao
    Chen, Jialei
    Xing, Fei
    Liu, Hao
    Xiang, Zhou
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [28] Comparison of femoral neck system versus cannulated screws for treatment of femoral neck fractures: a systematic review and meta-analysis
    Jiabao Jiang
    Jialei Chen
    Fei Xing
    Hao Liu
    Zhou Xiang
    BMC Musculoskeletal Disorders, 24
  • [29] Femoral neck system versus multiple cannulated screws for the fixation of Pauwels classification type II femoral neck fractures in older female patients with low bone mass
    Yeoh, Soon-Chin
    Wu, Wen-Tien
    Peng, Cheng-Huan
    Yao, Ting-Kuo
    Chang, Chia-Ming
    Liu, Kuan-Lin
    Yu, Tzai-Chiu
    Chen, Ing-Ho
    Wang, Jen-Hung
    Yeh, Kuang-Ting
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [30] Non-cannulated versus cannulated cancellous screws for the internal fixation of femoral neck fractures in osteoporotic patients: A single-blind randomized clinical trial
    Sadeghpour, Alireza
    Mahdipour, Shahab
    Sales, Jafar Ghanjpour
    Aslani, Hossein
    Moharrami, Mohammad Reza
    Alizadeh, Hadi
    JOURNAL OF ORTHOPAEDICS, 2024, 51 : 32 - 38