A pilot study for continuous non-invasive intracranial pressure screening

被引:0
|
作者
Pose, Fernando [1 ]
Videla, Carlos [2 ]
Campanini, Giovanni [1 ]
Redelico, Francisco O. [1 ,3 ]
Ciarrocchi, Nicolas [2 ]
机构
[1] Instituto de Medicina Translacional e Ingeniería Biomédica, CONICET-Hospital Italiano de Buenos Aires- Instituto Universitario del Hospital Italiano de Buenos Aires, Potosi 4265, Ciudad Autonoma de Buenos Aires
[2] Servicio de Terapia Intensiva de Adultos, Hospital Italiano de Buenos Aires, Tte. Gral. Juan Domingo Perón 4190, Ciudad Autonoma de Buenos Aires
[3] Departamento de Ciencia y Tecnologia, Universidad Nacional de Quilmes, Roque Sáenz Peña 352, Bernal, Provincia de Buenos Aires
关键词
Electroencephalogram; Intracranial pressure; Screening;
D O I
10.1016/j.compbiomed.2024.109611
中图分类号
学科分类号
摘要
Intracranial hypertension (ICH) is a common and critical condition in neurocritical care, often requiring immediate intervention. Current methods for continuous intracranial pressure (ICP) monitoring are invasive and costly, limiting their use in resource-limited settings. This study investigates the potential of the electroencephalography (EEG) as a non-invasive alternative for ICP monitoring. Using a generalized additive model (GAM) applied to porcine models, we analyzed the correlation between ICP and EEG features, including total EEG energy and the slope of the EEG power spectral density. Our model achieved moderate specificity (0.75) and sensitivity (0.73), accurately identifying 85% of ICH episodes with a 3-second window. These findings support the feasibility of using the EEG to detect ICH, particularly in low-resource environments. While further validation in human subjects is needed, our approach offers a promising, cost-effective method for non-invasive continuous ICP monitoring, enhancing ICH detection where traditional methods are impractical or inaccessible. © 2024
引用
收藏
相关论文
共 50 条
  • [41] Non-invasive measurement of intracranial pressure changes by otoacoustic emissions (OAEs) - a report of preliminary data
    Frank, AM
    Alexiou, C
    Hulin, P
    Janssen, T
    Arnold, W
    Trappe, AE
    ZENTRALBLATT FUR NEUROCHIRURGIE, 2000, 61 (04): : 177 - 180
  • [42] Non-invasive assessment of cerebral perfusion pressure in brain injured patients with moderate intracranial hypertension
    Edouard, AR
    Vanhille, E
    Le Moigno, S
    Benhamou, D
    Mazoit, JX
    BRITISH JOURNAL OF ANAESTHESIA, 2005, 94 (02) : 216 - 221
  • [43] Non-invasive Assessment of Intracranial Pressure in Severe Burned Patients: From Animal Models to Bedside
    Notaro, Maria
    Belotti, Laura M. B.
    Serafino, Marco D.
    Longobardi, Adele
    Villani, Romolo
    Aspide, Raffaele
    TRANSLATIONAL MEDICINE AT UNISA, 2024, 26 (01):
  • [44] Non-invasive screening for colorectal cancer in Asia
    Chiu, Han-Mo
    Chang, Li-Chun
    Hsu, Wen-Feng
    Chou, Chu-Kuang
    Wu, Ming-Shiang
    BEST PRACTICE & RESEARCH CLINICAL GASTROENTEROLOGY, 2015, 29 (06) : 953 - 965
  • [45] Non-invasive Intracranial Pressure Assessment in Brain Injured Patients Using Ultrasound-Based Methods
    Robba, Chiara
    Cardim, Danilo
    Tajsic, Tamara
    Pietersen, Justine
    Bulman, Michael
    Rasulo, Frank
    Bertuetti, Rita
    Donnelly, Joseph
    Liu Xiuyun
    Czosnyka, Zofia
    Cabeleira, Manuel
    Smielewski, Peter
    Matta, Basil
    Bertuccio, Alessandro
    Czosnyka, Marek
    INTRACRANIAL PRESSURE & NEUROMONITORING XVI, 2018, 126 : 69 - 73
  • [46] Influence of the mode of heating on cerebral blood flow, non-invasive intracranial pressure and thermal tolerance in humans
    Gibbons, Travis D.
    Ainslie, Philip N.
    Thomas, Kate N.
    Wilson, Luke C.
    Akerman, Ashley P.
    Donnelly, Joseph
    Campbell, Holly A.
    Cotter, Jim D.
    JOURNAL OF PHYSIOLOGY-LONDON, 2021, 599 (07): : 1977 - 1996
  • [47] Non-Invasive Intracranial Pressure Monitoring with Transcranial Doppler in a Patient with Progressive Cerebral Venous Sinus Thrombosis
    Wakerley, Benjamin
    Yohana, Kusuma
    Teoh, Hock Luen
    Tan, Clement W.
    Chan, Bernard P. L.
    Sharma, Vijay K.
    JOURNAL OF NEUROIMAGING, 2014, 24 (03) : 302 - 304
  • [48] Refining non-invasive techniques to measure intracranial pressure: comparing evoked and spontaneous tympanic membrane displacements
    Finch, Laurie C.
    Marchbanks, Robert J.
    Bulters, Diederik
    Birch, Anthony A.
    PHYSIOLOGICAL MEASUREMENT, 2018, 39 (02)
  • [49] New non-invasive biomarkers for colorectal cancer screening
    Duran-Sanchon, Saray
    Herrera-Pariente, Cristina
    Moreira, Leticia
    REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS, 2020, 112 (08) : 642 - 648
  • [50] Non-Invasive Methods for Intracranial Pressure Monitoring in Traumatic Brain Injury Using Transcranial Doppler: A Scoping Review
    Martinez-Palacios, Karol
    Vasquez-Garcia, Sebastian
    Fariyike, Olubunmi A.
    Robba, Chiara
    Rubiano, Andres M.
    JOURNAL OF NEUROTRAUMA, 2024, 41 (11-12) : 1282 - 1298