A pilot study for continuous non-invasive intracranial pressure screening

被引:0
|
作者
Pose, Fernando [1 ]
Videla, Carlos [2 ]
Campanini, Giovanni [1 ]
Redelico, Francisco O. [1 ,3 ]
Ciarrocchi, Nicolas [2 ]
机构
[1] Instituto de Medicina Translacional e Ingeniería Biomédica, CONICET-Hospital Italiano de Buenos Aires- Instituto Universitario del Hospital Italiano de Buenos Aires, Potosi 4265, Ciudad Autonoma de Buenos Aires
[2] Servicio de Terapia Intensiva de Adultos, Hospital Italiano de Buenos Aires, Tte. Gral. Juan Domingo Perón 4190, Ciudad Autonoma de Buenos Aires
[3] Departamento de Ciencia y Tecnologia, Universidad Nacional de Quilmes, Roque Sáenz Peña 352, Bernal, Provincia de Buenos Aires
关键词
Electroencephalogram; Intracranial pressure; Screening;
D O I
10.1016/j.compbiomed.2024.109611
中图分类号
学科分类号
摘要
Intracranial hypertension (ICH) is a common and critical condition in neurocritical care, often requiring immediate intervention. Current methods for continuous intracranial pressure (ICP) monitoring are invasive and costly, limiting their use in resource-limited settings. This study investigates the potential of the electroencephalography (EEG) as a non-invasive alternative for ICP monitoring. Using a generalized additive model (GAM) applied to porcine models, we analyzed the correlation between ICP and EEG features, including total EEG energy and the slope of the EEG power spectral density. Our model achieved moderate specificity (0.75) and sensitivity (0.73), accurately identifying 85% of ICH episodes with a 3-second window. These findings support the feasibility of using the EEG to detect ICH, particularly in low-resource environments. While further validation in human subjects is needed, our approach offers a promising, cost-effective method for non-invasive continuous ICP monitoring, enhancing ICH detection where traditional methods are impractical or inaccessible. © 2024
引用
收藏
相关论文
共 50 条
  • [1] Non-invasive assessment of intracranial pressure
    Robba, C.
    Bacigaluppi, S.
    Cardim, D.
    Donnelly, J.
    Bertuccio, A.
    Czosnyka, M.
    ACTA NEUROLOGICA SCANDINAVICA, 2016, 134 (01): : 4 - 21
  • [2] Non-invasive intracranial pressure assessment
    Llewellyn C. Padayachy
    Child's Nervous System, 2016, 32 : 1587 - 1597
  • [3] Non-Invasive Intracranial Pressure Monitoring
    Mueller, Sebastian Johannes
    Henkes, Elina
    Gounis, Matthew J.
    Felber, Stephan
    Ganslandt, Oliver
    Henkes, Hans
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (06)
  • [4] Non-invasive intracranial pressure assessment
    Padayachy, Llewellyn C.
    CHILDS NERVOUS SYSTEM, 2016, 32 (09) : 1587 - 1597
  • [5] Non-invasive Methods of Estimating Intracranial Pressure
    Rosenberg, Jamie B.
    Shiloh, Ariel L.
    Savel, Richard H.
    Eisen, Lewis A.
    NEUROCRITICAL CARE, 2011, 15 (03) : 599 - 608
  • [6] Non-invasive Methods of Estimating Intracranial Pressure
    Jamie B. Rosenberg
    Ariel L. Shiloh
    Richard H. Savel
    Lewis A. Eisen
    Neurocritical Care, 2011, 15 : 599 - 608
  • [7] Accuracy of non-invasive intracranial pressure measurement
    Seddighi, Amir Saied
    Zadeh, Alireza Moqareh
    Seddighi, Afsoun
    Zali, Alireza
    CENTRAL EUROPEAN JOURNAL OF MEDICINE, 2012, 7 (02): : 169 - 175
  • [8] Non-invasive monitoring of intracranial pressure changes: healthy volunteers study
    Roldan, Maria
    Bradley, George R. E.
    Mejia-Mejia, Elisa
    Abay, Tomas Y.
    Kyriacou, Panayiotis A.
    FRONTIERS IN PHYSIOLOGY, 2023, 14
  • [9] Evoked potentials - non-invasive indicators for intracranial pressure
    Engelhardt, W
    ANASTHESIOLOGIE INTENSIVMEDIZIN NOTFALLMEDIZIN SCHMERZTHERAPIE, 1997, 32 (02): : S250 - +
  • [10] An Ultrasonic Transceiver for Non-Invasive Intracranial Pressure Sensing
    Topalli, Gerald
    Fan, Yingying
    Cheung, Matt Y.
    Veeraraghavan, Ashok
    Hirzallah, Mohammad
    Chi, Taiyun
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2024, 18 (06) : 1220 - 1232