Experimental investigation of an electromagnetic seismic isolation system with different configurations of inertance

被引:2
|
作者
Lin, Ging-Long [1 ]
Chang, Chang-Ching [2 ]
Lin, Chih-Shiuan [3 ]
Lin, Chi-Chang [4 ]
Lin, Tzu-Ting [5 ]
Li, Yi-Huan [1 ]
机构
[1] Natl Kaohsiung Univ Sci & Technol, Dept Construction Engn, Kaohsiung, Taiwan
[2] Natl Ctr Res Earthquake Engn, Taipei, Taiwan
[3] Natl Cent Univ, Dept Civil Engn, Taoyuan, Taiwan
[4] Chaoyang Univ Technol, Natl Chung Hsing Univ, Dept Civil Engn, Dept Construction Engn, Taichung, Taiwan
[5] Natl Chung Hsing Univ, Dept Civil Engn, Taichung, Taiwan
关键词
Electromagnetic damper; Inertance; Flywheel; Seismic isolation; Near-fault earthquakes; Shaking table test; MASS-DAMPER-INERTER; VIBRATION ISOLATION; DYNAMIC-ANALYSIS; DEVICES; DESIGN; PERFORMANCE;
D O I
10.1016/j.jsv.2024.118698
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Protecting seismic isolated equipment or buildings in a near-fault area is challenging because of the strong long-period velocity components of near-fault ground motions. These long-period pulses can cause excessive base displacement of conventional seismic isolation systems. In this study, an electromagnetic seismic isolation system with flywheels (EMSIS-FW) was experimentally investigated to reduce the base displacement of isolation systems during near-fault earthquakes. The EMSIS-FW consists of a sliding platform and rotary electromagnetic (EM) dampers, which can provide an EM damping force. With an additional flywheel installed on each EM damper, its moment of inertia can offer a considerable inertance for the EMSIS-FW. The inertance generated by the flywheel can be hundreds of times larger than its mass. Accordingly, the isolation frequency can be adjusted using different-sized flywheels. A prototype EMSIS-FW was designed and manufactured. A theoretical model was also developed to predict its dynamic behavior. Through shaking table tests, this study provided experimental verification of the effectiveness of inertance on isolation systems subjected to near-fault ground motions. The experimental results indicate that an increase in inertance reduces the isolation displacement, but it may increase the isolation acceleration during a typical far-field ground motion. In addition, the accuracy of the theoretical model was verified using the shaking table test.
引用
收藏
页数:22
相关论文
共 50 条
  • [1] Theoretical and experimental analysis of an electromagnetic seismic isolation system
    Lin, Ging-Long
    Lin, Chi-Chang
    Li, Yi-Huan
    Lin, Tzu-Ting
    ENGINEERING STRUCTURES, 2022, 250
  • [2] Development of a novel semiactive electromagnetic seismic isolation system
    Lin, Ging-Long
    Chang, Ming-Bin
    Lin, Jian-Zuo
    ENGINEERING STRUCTURES, 2025, 333
  • [3] Experimental investigation on the seismic isolation for a legged wine storage tank
    Colombo, J. I.
    Almazan, J. L.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 133 : 167 - 180
  • [4] Application of a damping switch controller in semiactive electromagnetic seismic isolation systems
    Lin, Ging-Long
    Lin, Chi-Chang
    Lin, Jian-Zuo
    JOURNAL OF VIBRATION AND CONTROL, 2025,
  • [5] Experimental investigation of negative resistance shunted electromagnetic damping vibration isolation system
    Yan B.
    Zhang X.-N.
    Zhang, Xi-Nong (xnzhang@mail.xjtu.edu.cn), 1600, Nanjing University of Aeronautics an Astronautics (29): : 1057 - 1061
  • [6] Experimental Investigation on Seismic Behaviour of Hybrid Precast Beam-column Joints with Different Connection Configurations
    Zhang, Jianxin
    Zhang, Biao
    Rong, Xian
    Li, Yanyan
    Ding, Chuanlin
    JOURNAL OF EARTHQUAKE ENGINEERING, 2022, 26 (06) : 3123 - 3147
  • [7] Experimental investigation of cavitation in elastomeric seismic isolation bearings
    Kumar, Manish
    Whittaker, Andrew S.
    Constantinou, Michael C.
    ENGINEERING STRUCTURES, 2015, 101 : 290 - 305
  • [8] Dynamic Characterization and Design of Scotch Yoke Inerter with Adjustable Inertance for Seismic Isolation
    Tai, Yu-ji
    Hua, Xu-gang
    Cheng, Lu-lu
    Huang, Zhi-Wen
    Wang, Shi-long
    Wang, Zhen
    JOURNAL OF STRUCTURAL ENGINEERING, 2024, 150 (11)
  • [9] An experimental study on a generalized Maxwell model for nonlinear viscoelastic dampers used in seismic isolation
    Lu, Lyan-Ywan
    Lin, Ging-Long
    Shih, Ming-Hsiang
    ENGINEERING STRUCTURES, 2012, 34 : 111 - 123
  • [10] Experimental study of FPS system in bridge seismic isolation
    Tsopelas, P
    Constantinou, MC
    Kim, YS
    Okamoto, S
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1996, 25 (01) : 65 - 78