Evaluating Alternative Registration Planes in Imageless, Computer-Assisted Navigation Systems for Direct Anterior Total Hip Arthroplasty

被引:0
|
作者
Farey, John E. [1 ]
Chai, Yuan [1 ,2 ]
Xu, Joshua [3 ]
Maes, Vincent [1 ,4 ]
Sadeghpour, Ameneh [5 ]
Baker, Neri A. [5 ]
Vigdorchik, Jonathan M. [6 ]
Walter, William L. [1 ,3 ]
机构
[1] Univ Sydney, Fac Med & Hlth, Sydney Musculoskeletal Hlth, Kolling Inst,Northern Clin Sch, Camperdown, NSW 2064, Australia
[2] South China Univ Technol, Inst Future Hlth, Guangzhou 511442, Peoples R China
[3] Royal North Shore Hosp, Dept Orthoped & Traumat Surg, St Leonards, NSW 2065, Australia
[4] Univ Hosp Leuven, Dept Orthoped Surg, Herestr 49, B-3000 Leuven, Belgium
[5] Navbit, Innovat Dept, Sydney, NSW 2000, Australia
[6] Hosp Special Surg, Adult Reconstruct & Joint Replacement Serv, New York, NY 10021 USA
关键词
computer assisted surgery; imageless navigation; optical sensor; total hip arthroplasty; acetabular orientation; registration plane; implant accuracy; ACETABULAR COMPONENT; DISLOCATION; REVISION; ACCURACY; POSITION; RISK; WEAR;
D O I
10.3390/s24217092
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
(1) Background: Imageless computer navigation systems have the potential to improve the accuracy of acetabular cup position in total hip arthroplasty (THA). Popular imageless navigation methods include locating the patient in a three-dimensional space (registration method) while using a baseline to angle the acetabular cup (reference plane). This study aims to compare the accuracy of different methods for determining postoperative acetabular cup positioning in THA via the direct anterior approach. (2) Methods: Fifty-one participants were recruited. Optical and inertial sensor imageless navigation systems were used simultaneously with three combinations of registration methods and reference planes: the anterior pelvic plane (APP), the anterior superior iliac spine (ASIS) and the table tilt (TT) method. Postoperative acetabular cup position, inclination, and anteversion were assessed using CT scans. (3) Results: For inclination, the mean absolute error (MAE) was lower using the TT method (2.4 degrees +/- 1.7 degrees) compared to the ASIS (2.8 degrees +/- 1.7 degrees, p = 0.17) and APP method (3.7 degrees +/- 2.1 degrees, p < 0.001). For anteversion, the MAE was significantly lower for the TT method (2.4 degrees +/- 1.8 degrees) in contrast to the ASIS (3.9 degrees +/- 3.2 degrees, p = 0.005) and APP method (9.1 degrees +/- 6.2 degrees, p < 0.001). (4) Conclusion: A functional reference plane is superior to an anatomic reference plane to accurately measure intraoperative acetabular cup inclination and anteversion in THA using inertial imageless navigation systems.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Robotic-Arm Assisted Direct Anterior Total Hip Arthroplasty; Improving Implant Accuracy
    Xu, Sheng
    Bernardo, Lawrence Irving Calderon
    Yew, Andy Khye Soon
    Pang, Hee Nee
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2021, 38
  • [42] Accuracy of robotic arm-assisted versus computed tomography-based navigation in total hip arthroplasty using the direct anterior approach: a retrospective study
    Okazaki, Tomoya
    Imagama, Takashi
    Matsuki, Yuta
    Tanaka, Hiroshi
    Shiigi, Eiichi
    Kaneoka, Takehiro
    Kawakami, Takehiro
    Yamazaki, Kazuhiro
    Sakai, Takashi
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [43] Development and evaluation of an image-free computer-assisted impingement detection technique for total hip arthroplasty
    Renkawitz, Tobias
    Haimerl, Martin
    Dohmen, Lars
    Woerner, Michael
    Springorum, Hans-Robert
    Sendtner, Ernst
    Heers, Guido
    Weber, Markus
    Grifka, Joachim
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2012, 226 (H12) : 911 - 918
  • [44] Computer-assisted surgery for acetabular cup positioning in total hip arthroplasty: comparative prospective randomized study
    Parratte, S.
    Argenson, J.-N.
    Flecher, X.
    Aubaniac, J.-M.
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2007, 93 (03): : 238 - 246
  • [45] Combining inertial navigation with transacetabular ligament in total hip arthroplasty via direct anterior approach results in excellent accuracy compared to standard manual technique
    Maes, Vincent
    Cossetto, David
    SICOT-J, 2024, 10
  • [46] A Novel Registration Method for Computer-Assisted Total Knee Arthroplasty Using a Patient-Specific Registration Guide
    Jang, Taeho
    Lee, Kunwoo
    SURGICAL INNOVATION, 2014, 21 (01) : 80 - 89
  • [47] The Effect of Obesity on Fluoroscopy-Assisted Direct Anterior Approach Total Hip Arthroplasty
    Davidovitch, Roy I.
    Riesgo, Aldo M.
    Bolz, Nicholas J.
    Murphy, Hamadi
    Anoushiravani, Afshin A.
    Snir, Nimrod
    BULLETIN OF THE HOSPITAL FOR JOINT DISEASES, 2020, 78 (03): : 187 - 194
  • [48] Radiation Exposure During Fluoro-Assisted Direct Anterior Total Hip Arthroplasty
    Pomeroy, Christopher L.
    Mason, J. Bohannon
    Fehring, Thomas K.
    Masonis, John L.
    Curtin, Brian M.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (08) : 1742 - 1745
  • [49] Reliability and Correlation of the Force-PRO Device and Computer-Assisted Navigation System for Measurement of Acetabular Cup Position in Total Hip Arthroplasty
    Vijittrakarnrung, Chaiyanun
    Manupibul, Udomporn
    Charoensuk, Warakorn
    Wongsak, Siwadol
    Sa-Ngasoongsong, Paphon
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2020, 36
  • [50] Accuracy and Precision of Two Computer-Assisted Methods of Radiographic Wear Measurement in Total Hip Arthroplasty
    Crockarell, John R., Jr.
    Snearly, Christine M.
    JOURNAL OF ARTHROPLASTY, 2012, 27 (01) : 37 - 40