Evaluating Alternative Registration Planes in Imageless, Computer-Assisted Navigation Systems for Direct Anterior Total Hip Arthroplasty

被引:0
|
作者
Farey, John E. [1 ]
Chai, Yuan [1 ,2 ]
Xu, Joshua [3 ]
Maes, Vincent [1 ,4 ]
Sadeghpour, Ameneh [5 ]
Baker, Neri A. [5 ]
Vigdorchik, Jonathan M. [6 ]
Walter, William L. [1 ,3 ]
机构
[1] Univ Sydney, Fac Med & Hlth, Sydney Musculoskeletal Hlth, Kolling Inst,Northern Clin Sch, Camperdown, NSW 2064, Australia
[2] South China Univ Technol, Inst Future Hlth, Guangzhou 511442, Peoples R China
[3] Royal North Shore Hosp, Dept Orthoped & Traumat Surg, St Leonards, NSW 2065, Australia
[4] Univ Hosp Leuven, Dept Orthoped Surg, Herestr 49, B-3000 Leuven, Belgium
[5] Navbit, Innovat Dept, Sydney, NSW 2000, Australia
[6] Hosp Special Surg, Adult Reconstruct & Joint Replacement Serv, New York, NY 10021 USA
关键词
computer assisted surgery; imageless navigation; optical sensor; total hip arthroplasty; acetabular orientation; registration plane; implant accuracy; ACETABULAR COMPONENT; DISLOCATION; REVISION; ACCURACY; POSITION; RISK; WEAR;
D O I
10.3390/s24217092
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
(1) Background: Imageless computer navigation systems have the potential to improve the accuracy of acetabular cup position in total hip arthroplasty (THA). Popular imageless navigation methods include locating the patient in a three-dimensional space (registration method) while using a baseline to angle the acetabular cup (reference plane). This study aims to compare the accuracy of different methods for determining postoperative acetabular cup positioning in THA via the direct anterior approach. (2) Methods: Fifty-one participants were recruited. Optical and inertial sensor imageless navigation systems were used simultaneously with three combinations of registration methods and reference planes: the anterior pelvic plane (APP), the anterior superior iliac spine (ASIS) and the table tilt (TT) method. Postoperative acetabular cup position, inclination, and anteversion were assessed using CT scans. (3) Results: For inclination, the mean absolute error (MAE) was lower using the TT method (2.4 degrees +/- 1.7 degrees) compared to the ASIS (2.8 degrees +/- 1.7 degrees, p = 0.17) and APP method (3.7 degrees +/- 2.1 degrees, p < 0.001). For anteversion, the MAE was significantly lower for the TT method (2.4 degrees +/- 1.8 degrees) in contrast to the ASIS (3.9 degrees +/- 3.2 degrees, p = 0.005) and APP method (9.1 degrees +/- 6.2 degrees, p < 0.001). (4) Conclusion: A functional reference plane is superior to an anatomic reference plane to accurately measure intraoperative acetabular cup inclination and anteversion in THA using inertial imageless navigation systems.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Computer-assisted fluoroscopic navigation system for removal of distal femoral bone cement in revision total hip arthroplasty
    Akiyama, Haruhiko
    Kawanabe, Keiichi
    Goto, Koji
    Ohnishi, Eijiro
    Nakamura, Takashi
    JOURNAL OF ARTHROPLASTY, 2007, 22 (03) : 445 - 448
  • [32] A comparison of registration errors with imageless computer navigation during MIS total knee arthroplasty versus standard incision total knee arthroplasty: a cadaveric study
    Davis, Edward T.
    Pagkalos, Joseph
    Gallie, Price A. M.
    Macgroarty, Kelly
    Waddell, James P.
    Schemitsch, Emil H.
    COMPUTER AIDED SURGERY, 2015, 20 (01) : 7 - 13
  • [33] Comparison of Computer-Assisted Navigation and Conventional Instrumentation for Bilateral Total Knee Arthroplasty
    Weng, Yi-Jan
    Hsu, Robert Wen-Wei
    Hsu, Wei-Hsiu
    JOURNAL OF ARTHROPLASTY, 2009, 24 (05) : 668 - 673
  • [34] Computer-Assisted Navigation in Total Knee Arthroplasty without Femoral Hardware Removal
    Hernandez-Vaquero, D.
    Suarez-Vazquez, A.
    Iglesias-Fernandez, S.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2012, 79 (04) : 331 - 334
  • [35] Clinical outcomes of computer-assisted total knee arthroplasty using pinless navigation
    Jiang, Lei
    Chen, Jerry Yongqiang
    Chong, Hwei-Chi
    Chia, Shi-Lu
    Lo, Ngai-Nung
    Yeo, Seng Jin
    JOURNAL OF ORTHOPAEDIC SURGERY, 2017, 25 (01):
  • [36] Computer-assisted surgery in total hip arthroplasty A review of the literature and current concepts
    Beckmann, J.
    Springorum, H. R.
    Lechler, P.
    Luering, C.
    Tingart, M.
    Grifka, J.
    MINERVA ORTOPEDICA E TRAUMATOLOGICA, 2010, 61 (04) : 285 - 292
  • [37] Readmission rate and healthcare utilization outcomes of computer-assisted fluoroscopy-based hip navigation versus manual total hip arthroplasty
    Hamilton, William G. G.
    Sershon, Robert A. A.
    Gupta, Anshu
    Goldstein, Laura
    Kabiri, Mina
    Holy, Chantal E. E.
    Diaz, Rodrigo
    EXPERT REVIEW OF MEDICAL DEVICES, 2023, 20 (09) : 779 - 789
  • [38] Does Robotic-Assisted Computer Navigation Affect Acetabular Cup Positioning in Total Hip Arthroplasty in the Obese Patient? A Comparison Study
    Gupta, Asheesh
    Redmond, John M.
    Hammarstedt, Jon E.
    Petrakos, Alexandra E.
    Vemula, S. Pavan
    Domb, Benjamin G.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (12) : 2204 - 2207
  • [39] Does computer-assisted surgery benefit leg length restoration in total hip replacement? Navigation versus conventional freehand
    Manzotti, Alfonso
    Cerveri, Pietro
    De Momi, Elena
    Pullen, Chris
    Confalonieri, Norberto
    INTERNATIONAL ORTHOPAEDICS, 2011, 35 (01) : 19 - 24
  • [40] Total knee arthroplasty using computer-assisted navigation in patients with deformities of the femur and tibia
    Klein, GR
    Austin, MS
    Smith, EB
    Hozack, WJ
    JOURNAL OF ARTHROPLASTY, 2006, 21 (02) : 284 - 288