Quantitative Comparison of Color-Coded Parametric Imaging Technologies Based on Digital Subtraction and Digital Variance Angiography: A Retrospective Observational Study

被引:0
|
作者
Gog, Istvan [1 ,2 ]
Sotonyi, Peter [1 ]
Nemes, Balazs [3 ]
Kiss, Janos P. [2 ]
Szigeti, Krisztian [4 ]
Osvath, Szabolcs [2 ,4 ]
Gyano, Marcell [2 ,3 ]
机构
[1] Semmelweis Univ, Heart & Vasc Ctr, Dept Vac & Endovasc Surg, Varosmajor Utca 68, H-1122 Budapest, Hungary
[2] Kinepict Hlth Ltd, Szilagyi Erzsebet Fasor 31, H-1027 Budapest, Hungary
[3] Semmelweis Univ, Heart & Vasc Ctr, Dept Intervent Radiol, Varosmajor Utca 68, H-1122 Budapest, Hungary
[4] Semmelweis Univ, Dept Biophys & Radiat Biol, Tuzolto U 37-47, H-1094 Budapest, Hungary
关键词
color-coded parametric imaging; digital subtraction angiography; digital variance angiography; time-density curve; peripheral artery disease; critical limb ischemia; ARTERY; FLOW;
D O I
10.3390/jimaging10100260
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
The evaluation of hemodynamic conditions in critical limb-threatening ischemia (CLTI) patients is inevitable in endovascular interventions. In this study, the performance of color-coded digital subtraction angiography (ccDSA) and the recently developed color-coded digital variance angiography (ccDVA) was compared in the assessment of key time parameters in lower extremity interventions. The observational study included 19 CLTI patients who underwent peripheral vascular intervention at our institution in 2020. Pre- and post-dilatational images were retrospectively processed and analyzed by a commercially available ccDSA software (Kinepict Medical Imaging Tool 6.0.3; Kinepict Health Ltd., Budapest, Hungary) and by the recently developed ccDVA technology. Two protocols were applied using both a 4 and 7.5 frames per second acquisition rate. Time-to-peak (TTP) parameters were determined in four pre- and poststenotic regions of interest (ROI), and ccDVA values were compared to ccDSA read-outs. The ccDVA technology provided practically the same TTP values as ccDSA (r = 0.99, R-2 = 0.98, p < 0.0001). The correlation was extremely high independently of the applied protocol or the position of ROI; the r value was 0.99 (R-2 = 0.98, p < 0.0001) in all groups. A similar correlation was observed in the change in passage time (r = 0.98, R-2 = 0.96, p < 0.0001). The color-coded DVA technology can reproduce the same hemodynamic data as a commercially available DSA-based software; therefore, it has the potential to be an alternative decision-supporting tool in catheter labs.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Digital subtraction angiography findings of stroke in young adult population: a multi-center record-based study
    Tini, Kumara
    Tedyanto, Eric Hartono
    Andaka, Deddy
    Pramana, Nyoman Angga Krishna
    Widyadharma, I. Putu Eka
    EGYPTIAN JOURNAL OF NEUROLOGY PSYCHIATRY AND NEUROSURGERY, 2023, 59 (01)
  • [42] Assessment of carotid atherosclerotic disease using three-dimensional cardiovascular magnetic resonance vessel wall imaging: comparison with digital subtraction angiography
    Wang, Zhenjia
    Lu, Mi
    Liu, Wen
    Zheng, Tiejin
    Li, Debiao
    Yu, Wei
    Fan, Zhaoyang
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2020, 22 (01)
  • [43] Diagnosis and treatment efficacy of digital subtraction angiography and transcatheter arterial embolization in post-pancreatectomy hemorrhage: A single center retrospective cohort study
    Fang, Yuan
    Han, Xu
    Liu, Lingxiao
    Lou, Wenhui
    INTERNATIONAL JOURNAL OF SURGERY, 2018, 51 : 223 - 228
  • [44] Comparison Between Time-Resolved Magnetic Resonance Angiography and Diagnostic Digital Subtraction Angiography in the Vascular Assessment of Nonspecific Aorto-Arteritis Patients: A Prospective Study
    Chandrashekhara, Sheragaru Hanumanthappa
    Gulati, Gurpreet Singh
    Sharma, Sanjiv
    Jagia, Priya
    Kumar, Sanjeev
    Choudhary, Shiv
    VASCULAR AND ENDOVASCULAR SURGERY, 2021, 55 (06) : 586 - 592
  • [45] Parametric Color Coding of Digital Subtraction Angiography in the Evaluation of Carotid Cavernous FistulasParametrische Farbkodierung der digitalen Subtraktionsangiografie für die Evaluierung von Karotis-avernosus Fisteln
    P. Gölitz
    T. Struffert
    H. Lücking
    J. Rösch
    F. Knossalla
    O. Ganslandt
    Y. Deuerling-Zheng
    A. Doerfler
    Clinical Neuroradiology, 2013, 23 (2) : 113 - 120
  • [46] Application of zero echo time MR angiography in follow-up of intracranial aneurysm remnant and in-stent lumen after embolization: a comparison study with digital subtraction angiography
    Song, Yan
    Qi, Peng
    Huang, Juan
    Jiao, Sheng
    Zhang, Jintao
    Wang, Daming
    Chen, Min
    ACTA RADIOLOGICA, 2020, 61 (04) : 480 - 486
  • [47] Quantitative contrast enhanced magnetic resonance imaging for the evaluation of peripheral arterial disease: a comparative study versus standard digital angiography
    Chris Pavlovic
    Hideki Futamatsu
    Dominick J. Angiolillo
    Luis A. Guzman
    Norbert Wilke
    Daniel Siragusa
    Peter Wludyka
    Robert Percy
    Martin Northrup
    Theodore A. Bass
    Marco A. Costa
    The International Journal of Cardiovascular Imaging, 2007, 23
  • [48] Imaging modalities for renal artery stenosis in suspected renovascular hypertension: Prospective intraindividual comparison of color Doppler US, CT angiography, GD-enhanced MR angiography, and digital substraction angiography
    Rountas, C.
    Vlychou, M.
    Vassiou, K.
    Liakopoulos, V.
    Kapsalaki, E.
    Koukoulis, G.
    Fezoulidis, I. V.
    Stefanidis, I.
    RENAL FAILURE, 2007, 29 (03) : 295 - 302
  • [49] Quantitative contrast enhanced magnetic resonance imaging for the evaluation of peripheral arterial disease: a comparative study versus standard digital angiography
    Pavlovic, Chris
    Futamatsu, Hideki
    Angiolillo, Dominick J.
    Guzman, Luis A.
    Wilke, Norbert
    Siragusa, Daniel
    Wfudyka, Peter
    Percy, Robert
    Northrup, Martin
    Bass, Theodore A.
    Costa, Marco A.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2007, 23 (02) : 225 - 232
  • [50] Preoperative Evaluation of Hilar Cholangiocarcinoma with Contrast-enhanced Three-dimensional Fast Imaging with Steady-state Precession Magnetic Resonance Angiography: Comparison with Intraarterial Digital Subtraction Angiography
    Moon-Gyu Lee
    Kwang Bo Park
    Yong Moon Shin
    Hyun Ki Yoon
    Kyu Bo Sung
    Myung Hwan Kim
    Sung Gyu Lee
    Eun Mee Kang
    World Journal of Surgery, 2003, 27 : 278 - 283