Quantitative Comparison of Color-Coded Parametric Imaging Technologies Based on Digital Subtraction and Digital Variance Angiography: A Retrospective Observational Study

被引:0
|
作者
Gog, Istvan [1 ,2 ]
Sotonyi, Peter [1 ]
Nemes, Balazs [3 ]
Kiss, Janos P. [2 ]
Szigeti, Krisztian [4 ]
Osvath, Szabolcs [2 ,4 ]
Gyano, Marcell [2 ,3 ]
机构
[1] Semmelweis Univ, Heart & Vasc Ctr, Dept Vac & Endovasc Surg, Varosmajor Utca 68, H-1122 Budapest, Hungary
[2] Kinepict Hlth Ltd, Szilagyi Erzsebet Fasor 31, H-1027 Budapest, Hungary
[3] Semmelweis Univ, Heart & Vasc Ctr, Dept Intervent Radiol, Varosmajor Utca 68, H-1122 Budapest, Hungary
[4] Semmelweis Univ, Dept Biophys & Radiat Biol, Tuzolto U 37-47, H-1094 Budapest, Hungary
关键词
color-coded parametric imaging; digital subtraction angiography; digital variance angiography; time-density curve; peripheral artery disease; critical limb ischemia; ARTERY; FLOW;
D O I
10.3390/jimaging10100260
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
The evaluation of hemodynamic conditions in critical limb-threatening ischemia (CLTI) patients is inevitable in endovascular interventions. In this study, the performance of color-coded digital subtraction angiography (ccDSA) and the recently developed color-coded digital variance angiography (ccDVA) was compared in the assessment of key time parameters in lower extremity interventions. The observational study included 19 CLTI patients who underwent peripheral vascular intervention at our institution in 2020. Pre- and post-dilatational images were retrospectively processed and analyzed by a commercially available ccDSA software (Kinepict Medical Imaging Tool 6.0.3; Kinepict Health Ltd., Budapest, Hungary) and by the recently developed ccDVA technology. Two protocols were applied using both a 4 and 7.5 frames per second acquisition rate. Time-to-peak (TTP) parameters were determined in four pre- and poststenotic regions of interest (ROI), and ccDVA values were compared to ccDSA read-outs. The ccDVA technology provided practically the same TTP values as ccDSA (r = 0.99, R-2 = 0.98, p < 0.0001). The correlation was extremely high independently of the applied protocol or the position of ROI; the r value was 0.99 (R-2 = 0.98, p < 0.0001) in all groups. A similar correlation was observed in the change in passage time (r = 0.98, R-2 = 0.96, p < 0.0001). The color-coded DVA technology can reproduce the same hemodynamic data as a commercially available DSA-based software; therefore, it has the potential to be an alternative decision-supporting tool in catheter labs.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Quantitative color-coded digital subtraction neuroangiography for pediatric arteriovenous shunting lesions
    Grace M. Y. Ma
    Adam A. Dmytriw
    Premal A. Patel
    Nicholas Shkumat
    Timo Krings
    Manohar M. Shroff
    Prakash Muthusami
    Child's Nervous System, 2019, 35 : 2399 - 2403
  • [2] Quantitative color-coded digital subtraction neuroangiography for pediatric arteriovenous shunting lesions
    Ma, Grace M. Y.
    Dmytriw, Adam A.
    Patel, Premal A.
    Shkumat, Nicholas
    Krings, Timo
    Shroff, Manohar M.
    Muthusami, Prakash
    CHILDS NERVOUS SYSTEM, 2019, 35 (12) : 2399 - 2403
  • [3] Color-coded Digital Subtraction Angiography for Assessing Acute Skeletal Muscle Ischemia-Reperfusion Injury in a Rabbit Model
    Zhang, Yan
    Li, Chengzhi
    Zhang, Hong
    Li, Wanghai
    Li, Jinwei
    Wang, Xiaobai
    ACADEMIC RADIOLOGY, 2018, 25 (12) : 1609 - 1616
  • [4] Detection of Intracranial Arterial Stenosis Using Transcranial Color-Coded Duplex Sonography, Computed Tomographic Angiography, and Digital Subtraction Angiography
    Roubec, Martin
    Kuliha, Martin
    Jonszta, Tomas
    Prochazka, Vaclav
    Fadrna, Tana
    Filip, Michal
    Kanovsky, Petr
    Langova, Katerina
    Herzig, Roman
    Skoloudik, David
    JOURNAL OF ULTRASOUND IN MEDICINE, 2011, 30 (08) : 1069 - 1075
  • [5] Complex combination of femoropopliteal occlusive disease and arteriovenous fistula treated using color-coded digital subtraction angiography
    Iwakoshi, Shinichi
    Konishi, Kengo
    Inoue, Takeshi
    Watkins, Amelia Claire
    Ichihashi, Shigeo
    Kichikawa, Kimihiko
    JOURNAL OF VASCULAR SURGERY CASES AND INNOVATIVE TECHNIQUES, 2019, 5 (03): : 264 - 268
  • [6] Application of color-coded digital subtraction angiography in treatment of indirect carotid-cavernous fistulas: Initial experience
    Lin, Chung-Jung
    Luo, Chao-Bao
    Hung, Sheng-Che
    Guo, Wan-Yuo
    Chang, Feng-Chi
    Beilner, Janina
    Kowarschik, Markus
    Chu, Wei-Fa
    Chang, Cheng-Yen
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2013, 76 (04) : 218 - 224
  • [7] Evaluation of skeletal muscle perfusion in canine hind limb ischemia model using color-coded digital subtraction angiography
    Wang, Tao
    Su, Haobo
    Lou, Wensheng
    Gu, Jianping
    He, Xu
    Chen, Liang
    Chen, Guoping
    Song, Jinhua
    Shi, Wanyin
    Zee, Chishing
    Chen, Bihong T.
    MICROVASCULAR RESEARCH, 2019, 123 : 81 - 85
  • [8] Association of intracranial arteriovenous malformation embolization with more rapid rate of perfusion in the peri-nidal region on color-coded quantitative digital subtraction angiography
    Shellikeri, Sphoorti
    Bai, Harrison
    Setser, Randolph M.
    Hurst, Robert W.
    Cahill, Anne Marie
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2020, 12 (09) : 902 - +
  • [9] Characterizing tissue perfusion after lower extremity intervention using two-dimensional color-coded digital subtraction angiography
    Kim, Ann H.
    Shevitz, Andrew J.
    Morrow, Katherine L.
    Kendrick, Daniel E.
    Harth, Karem
    Baele, Henry
    Kashyap, Vikram S.
    JOURNAL OF VASCULAR SURGERY, 2017, 66 (05) : 1464 - 1472
  • [10] Parametric Color Coding of Digital Subtraction Angiography in the Evaluation of Carotid Cavernous Fistulas
    Goelitz, P.
    Struffert, T.
    Luecking, H.
    Roesch, J.
    Knossalla, F.
    Ganslandt, O.
    Deuerling-Zheng, Y.
    Doerfler, A.
    CLINICAL NEURORADIOLOGY, 2013, 23 (02) : 113 - 120