Experimental investigation on the effect of concentration on the resonance frequency of lipid coated ultrasonically excited microbubbles

被引:0
|
作者
Haghi, Hossein [1 ,2 ,3 ]
Yaali, Mahshid [1 ,2 ,3 ]
Exner, Agata A. [4 ]
Kolios, Michael C. [1 ,2 ,3 ]
机构
[1] Toronto Metropolitan Univ, 350 Victoria St, Toronto, ON, Canada
[2] St Michaels Hosp, Inst Biomed Engn Sci & Technol iBEST, 209 Victoria St, Toronto, ON, Canada
[3] Toronto Metropolitan Univ, 209 Victoria St, Toronto, ON, Canada
[4] Case Western Reserve Univ, Dept Radiol, Cleveland, OH 44106 USA
基金
加拿大自然科学与工程研究理事会;
关键词
Bubble dynamics; Cavitation; Ultrasound; Bubble-bubble interaction; Microbubbles; Ultrasound contrast agents; ULTRASOUND CONTRAST AGENTS; BLOOD-BRAIN-BARRIER; FOCUSED ULTRASOUND; ENCAPSULATED MICROBUBBLES; CAVITATION; THERAPY; MONODISPERSE; TEMPERATURE; SENSITIVITY; ABLATION;
D O I
10.1016/j.ultsonch.2024.107170
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This study presents an experimental investigation of the influence of MB concentration on the resonance frequency of lipid-coated microbubbles (MBs). Expanding on theoretical models and numerical simulations from previous research, this work experimentally investigates the effect of MB size on the rate of resonance frequency increase with concentration, a phenomenon observed across MBs with two different lipid compositions: propylene glycol (PG) and propylene glycol and glycerol (PGG). Employing a custom-designed ultrasound attenuation measurement setup, we measured the frequency-dependent attenuation of MBs, isolating MBs based on size to generate distinct monodisperse sub-populations for analysis. The resonance frequency of MBs was determined by identifying the attenuation peak in the broadband attenuation ultrasound attenuation measurements. Our experimental findings confirm that larger MBs ( approximate to 2 . 1 mu m) demonstrate amore significant shift in resonance frequency (approximate to 5 MHz, approximate to 40%) as a function of MB concentration. In contrast, smaller MBs ( approximate to 1 . 3 mu m) show a minor shift in the resonant frequency (approximate to 1.8 MHz, approximate to 8%), underlining the importance of size in determining acoustic behavior compared to changes in the lipid shell properties. Additionally, we observed that resonance frequency increase with concentration reaching a saturation point at higher concentrations. This plateau occurs at higher concentrations for larger MBs ( approximate to 2 . 1 mu m ), while smaller MBs ( approximate to 1 . 6 mu m and approximate to 1.3 mu m) reach this saturation point at lower concentrations. Furthermore, the study highlights the small effect of bubble-bubble interactions on the resonance frequency of MB populations, particularly at lower MB concentrations and for smaller MBs. This insight is important for applications utilizing MB clusters, such as contrast-enhanced ultrasound imaging and MB-mediated therapies. While both size and lipid shell composition influence resonance frequency, MB size has a more significant effect. In conclusion, our findings affirm the need to consider both MB size and concentration when utilizing MBs for clinical and industrial ultrasonic applications.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Numerical and Experimental Stability Investigation of a Parametrically Excited Cantilever Beam at Combination Parametric Resonance
    Tehrani, G. Ghannad
    Gastaldi, C.
    Berruti, T. M.
    EXPERIMENTAL MECHANICS, 2023, 63 (01) : 177 - 190
  • [22] AN EXPERIMENTAL INVESTIGATION OF DOPPLER EFFECT AT ELECTRON CYCLOTRON FREQUENCY
    IVANOV, BI
    SOVIET PHYSICS JETP-USSR, 1969, 28 (01): : 23 - &
  • [23] INVESTIGATION OF HUMAN TACTILE STOCHASTIC RESONANCE DEPENDING ON FREQUENCY EFFECT
    Beceren, Kadir
    Ohka, Masahiro
    Miyaoka, Tetsu
    Yussof, Hanafiah
    Makhtar, Ahmad Khushairy
    Basir, Siti Nora
    INTERNATIONAL JOURNAL ON SMART SENSING AND INTELLIGENT SYSTEMS, 2013, 6 (05) : 2334 - 2349
  • [24] EXPERIMENTAL INVESTIGATION AND REVIEW OF THE SOLIDS CONCENTRATION EFFECT IN ADSORPTION STUDIES
    MCKINLEY, JP
    JENNE, EA
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1991, 25 (12) : 2082 - 2087
  • [25] An Experimental Investigation on Effect of Cutting Fluids in Turning with Coated Carbides Tool
    Isik, Yahya
    STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2010, 56 (03): : 195 - 201
  • [26] An experimental investigation on effect of cutting fluids in turning with coated carbides tool
    University of Uludaǧ, Department of Technical Science, Vocational School of Higher Education, Turkey
    Stroj Vest, 3
  • [27] Experimental investigation of the electron sheath resonance (ESR) effect in parallel plate radio-frequency capacitively coupled plasmas
    Ding, Ling-ling
    Lu, Wen-qi
    Zhang, Quan-zhi
    Xu, Jun
    Ding, Zhen-feng
    Wang, You-nian
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2022, 31 (04):
  • [28] Experimental investigation on effect of corrosion on resonant frequency of concrete cylinders
    Kanchana Devi, A.
    Sivasubramanian, K.
    Ramajaneyulu, K.
    Journal of Structural Engineering (India), 2015, 42 (02): : 106 - 113
  • [29] EXPERIMENTAL INVESTIGATION OF ULTRASONIC FREQUENCY EFFECT ON AN OSCILLATING HEAT PIPE
    Zhao, Nannan
    Fu, Benwei
    Ma, Hongbin
    Su, Fengmin
    PROCEEDINGS OF THE ASME 5TH INTERNATIONAL CONFERENCE ON MICRO/NANOSCALE HEAT AND MASS TRANSFER, 2016, VOL 2, 2016,
  • [30] EXPERIMENTAL RESULTS ON RESONANCE FREQUENCY DUE TO DYNAMIC EFFECT OF LIQUID CORE
    BLUM, PA
    HATZFELD, D
    WITTLINGER, G
    COMPTES RENDUS HEBDOMADAIRES DES SEANCES DE L ACADEMIE DES SCIENCES SERIE B, 1973, 277 (10): : 241 - 244