Simultaneous degradation of contaminants of emerging concern and disinfection by solar photoelectro-Fenton process at circumneutral pH in a solar electrochemical raceway pond reactor

被引:2
|
作者
Herrera-Muñoz J. [1 ,2 ,3 ]
Cabrera-Reina A. [2 ]
Miralles-Cuevas S. [2 ]
Piña S. [1 ]
Salazar-González R. [3 ]
机构
[1] Facultad de Química y Biología, Universidad de Santiago de Chile, USACH, Casilla 40, Correo 33, Santiago
[2] Programa Institucional de Fomento a la I+D+i, Universidad Tecnológica Metropolitana, Ignacio Valdivieso 2409, P.O. Box 8940577, Santiago, San Joaquín
[3] Grupo de Investigación de Análisis, Tratamiento, Electroquímica, Recuperación y Reúso de Agua (WATER2), Departamento de Química Inorgánica, Facultad de Química y de Farmacia, Pontificia Universidad Católica de Chile
关键词
Circumneutral pH; Pilot plant; Real secondary effluent; Response surface model; Solar wastewater treatment;
D O I
10.1016/j.chemosphere.2023.139978
中图分类号
学科分类号
摘要
Simultaneous contaminants of emerging concern (CECs) removal and wild microorganisms’ inactivation was evaluated by applying solar photoelectro-Fenton (SPEF) process in actual secondary effluent collected from a real municipal wastewater treatment plant (MWWTP). 20 L of a mixture of four CECs was used as model pollutants (200 μg/L of acetaminophen, caffeine, sulfamethazine, and sulfamethoxazole each one). The SPEF process was carried out on fully sunny days, at circumneutral pH using the complex Fe3+-EDDS, in a solar electrochemical – raceway pond reactor (SEC-RPR). Initially, the optimal conditions for CECs degradation were determined using a response surface model based on current density, iron complex concentration and Fe3+-EDDS addition time (to allow previous accumulation of H2O2) as model inputs. A current density of 24.6 mA/cm2, a Fe3+-EDDS complex concentration of 0.089 mM and 3.8 min of previous H2O2 accumulation were the resulting optimum conditions that were afterwards applied for the simultaneous degradation of the CECs synthetic mixture and wild microorganisms inactivation in actual secondary effluent. About 85% CECs removal and complete E. coli inactivation were achieved in 30 min, approximately, while E. faecalis and total coliforms could be inactivated under detection limit in 60 min and 75 min, respectively. © 2023
引用
收藏
相关论文
共 3 条
  • [1] Removal of contaminants of emerging concern by continuous flow solar photo-Fenton process at neutral pH in open reactors
    Arzate, S.
    Campos-Manas, M. C.
    Miralles-Cuevas, S.
    Aguera, A.
    Garcia Sanchez, J. L.
    Sanchez Perez, J. A.
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2020, 261
  • [2] An efficient simultaneous degradation of sulfamethoxazole and trimethoprim by photoelectro-Fenton process under non-modified pH using a natural citric acid source: study of biodegradability, ecotoxicity, and antibacterial activity
    Carlos Andrés Delgado-Vargas
    Paula Andrea Espinosa-Barrera
    Paola Villegas-Guzman
    Diana Martínez-Pachón
    Alejandro Moncayo-Lasso
    Environmental Science and Pollution Research, 2022, 29 : 42275 - 42289
  • [3] An efficient simultaneous degradation of sulfamethoxazole and trimethoprim by photoelectro-Fenton process under non-modified pH using a natural citric acid source: study of biodegradability, ecotoxicity, and antibacterial activity
    Andres Delgado-Vargas, Carlos
    Andrea Espinosa-Barrera, Paula
    Villegas-Guzman, Paola
    Martinez-Pachon, Diana
    Moncayo-Lasso, Alejandro
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2022, 29 (28) : 42275 - 42289