Cyclic performance of precast segmented bridge pier with inner column socket connection: A parametric study

被引:0
|
作者
Al-Shaebi, Rashad [1 ]
Al-Haaj, Mohammed [1 ]
Zhang, Dan [2 ]
Li, Ning [1 ,3 ,4 ,5 ]
Jia, Junfeng [6 ]
机构
[1] School of Civil Engineering, Tianjin University, Tianjin,300350, China
[2] School of Civil and Transportation Engineering, Hebei University of Technology, Tianjin,300401, China
[3] State Key Laboratory of Hydraulic Engineering Intelligent Construction and Operation, Tianjin,300350, China
[4] Key Laboratory of Coast Civil Structures Safety of Ministry of Education (Tianjin University), Tianjin,300350, China
[5] Key Laboratory of Earthquake Engineering Simulation and Seismic Resilience of China Earthquake Administration (Tianjin University), Tianjin,300350, China
[6] Key Laboratory of Urban Security and Disaster Engineering of Ministry of Education, Beijing University of Technology, Beijing,100124, China
来源
Structures | 2024年 / 62卷
基金
中国国家自然科学基金;
关键词
ABAQUS - Bearing capacity - Cementing (shafts) - Energy dissipation - Hysteresis - Reinforcement - Software testing - Stiffness;
D O I
暂无
中图分类号
学科分类号
摘要
To enhance the lateral bearing capacity and resilience of precast segmented bridge piers (PSBPs), a novel inner column (IC) socket connection at the bottom of the pier was proposed. The performance of the joint of the precast column and footing block determines the lateral bearing capacity of the pier and the bridge. Therefore, the joint adopts high-performance concrete (HPC) and engineered cementation composite (ECC) ICs. The cyclic performance of IC socket connection under pseudo-static tests with constant vertical loading was investigated. Numerical models against four bridge pier-tested specimens cited in the references were developed utilizing the OpenSees platform and ABAQUS software to verify modeling accuracy. Accordingly, three piers, two PSBPs with varying IC materials, and one standard PSBP without an IC were studied to confirm the effectiveness of IC in the PSBP system. Then, parametric analyses of their impact on PSBPs with IC were conducted, examining variables of the height ratio, cross-section area, concrete strength, reinforcement ratio, and reinforcement yield strength ratios of the IC in addition to vertical loading ratio and post-tension tendon area. The findings indicate that existing the IC improves PSBP performance in terms of hysteretic behavior, ductility, energy dissipation, and stiffness while ensuring self-centering behavior is within the acceptable range. Furthermore, a well-designed IC can effectively regulate the lateral resistance capacity and resilience performance of PSBPs. For PSBP construction, the IC socket connection utilizing modern materials is an effective connector and versatile for future bridge structure applications. © 2024 Institution of Structural Engineers
引用
收藏
相关论文
共 50 条
  • [41] The Performance Assessment of a Precast, Panel-Segmented Arch Bridge with Outriggers
    Jeon, Seok Hyeon
    Cho, Kwang-Il
    Huh, Jungwon
    Ahn, Jin-Hee
    APPLIED SCIENCES-BASEL, 2019, 9 (21):
  • [42] Cyclic Loading Tests of Novel Precast Bridge Columns with Off-Site Post-Tensioned Tendons and On-Site Socket Connection
    Jia, Junfeng
    Bian, Jiachen
    Xu, Kun
    Qiu, Canxing
    Du, Xiuli
    Guo, He
    Pang, Wei
    JOURNAL OF EARTHQUAKE ENGINEERING, 2025, 29 (04) : 791 - 815
  • [43] Seismic performance of precast assembled bridge piers with hybrid connection
    Zou, Shuang
    Wenliuhan, Heisha
    Liu, Yanhui
    Zhai, Zhipeng
    Zhang, Chongbin
    STRUCTURAL ENGINEERING AND MECHANICS, 2023, 85 (03) : 407 - 417
  • [44] Cyclic shear test on a dowel beam-to-column connection of precast buildings
    Magliulo, Gennaro
    Ercolino, Marianna
    Cimmino, Maddalena
    Capozzi, Vittorio
    Manfredi, Gaetano
    EARTHQUAKES AND STRUCTURES, 2015, 9 (03) : 541 - 562
  • [45] Precast Concrete Column Beam Connection Using Dowels Due to Cyclic Load
    Tumengkol, Herman A.
    Irmawaty, Rita
    Parung, Herman
    Amiruddin, Arwin
    INTERNATIONAL JOURNAL OF ENGINEERING, 2022, 35 (01):
  • [46] Experimental and numerical study on precast socket columns due to impact at the column top
    Meng, Dongliang
    Peng, Wenqiang
    Yang, Menggang
    Hu, Renkang
    Hu, Shangtao
    STRUCTURES, 2025, 73
  • [47] Performance of the Modified Precast Beam to Column Connection Placed on a Concrete Corbel
    Bahrami, S.
    Madhkhan, M.
    CIVIL ENGINEERING INFRASTRUCTURES JOURNAL-CEIJ, 2019, 52 (02): : 365 - 377
  • [48] Precast segmental bridge pier structure with combined shear keys and seismic performance analysis
    Li, Chen
    Jiang, Hui
    Guo, Hui
    Ma, Xinyi
    Song, Guangsong
    Zhendong yu Chongji/Journal of Vibration and Shock, 2021, 40 (20): : 117 - 126
  • [49] Experimental investigation of a new precast column-foundation connection under cyclic loading
    Cogurcu, Mustafa Tolga
    Uzun, Mehmet
    JOURNAL OF BUILDING ENGINEERING, 2022, 50
  • [50] Experimental study of a new beam-to-column connection for precast concrete frames under reversal cyclic loading
    Guan, Dongzhi
    Guo, Zhengxing
    Xiao, Quandong
    Zheng, Yongfeng
    ADVANCES IN STRUCTURAL ENGINEERING, 2016, 19 (03) : 529 - 545