Characteristics of conductor dynamic tension during galloping for 500 kV power transmission line with 6-bundle

被引:0
|
作者
Yang, Xiao-Hui [1 ,2 ]
Zhang, Bo [2 ]
Yang, Wei [2 ]
Fu, Zheng-Cai [1 ]
机构
[1] Electric Department, Shanghai Jiaotong University, Shanghai,200030, China
[2] Electric Power Research Institute, Henan Electric Power Company, Zhengzhou,450052, China
关键词
Wind - Excited states - Electric lines;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:1218 / 1224
相关论文
共 50 条
  • [21] Impact analysis of transmission line span combination on dynamic characteristics of iced conductor
    Zhang, H. (zhangying03292000@yahoo.com.cn), 1600, Science Press (39):
  • [22] Fundamental characteristics of overhead transmission line galloping determined by simulating calculation using equivalent single-conductor method
    Yamaoka, M
    Hasegawa, J
    ELECTRICAL ENGINEERING IN JAPAN, 1995, 115 (07) : 11 - 28
  • [23] Research on Dynamic Simulation of Power Transmission Line Galloping in Three-Degree-of-Freedom Model
    Wu, Shijing
    Liu, Zhenhao
    Wang, Xiaosun
    Hu, Jicai
    Feng, Qingdong
    Ren, Hui
    Wu, Yuzhi
    PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING AND MECHANICS, VOLS 1 AND 2, 2009, : 1073 - 1081
  • [24] Determination of the transmission capacity of a 500-kV line equipped with flexible electric power transmission devices
    Ignatenko I.V.
    Konstantinov A.M.
    Demina L.S.
    Russian Electrical Engineering, 2016, 87 (2) : 104 - 106
  • [25] Experimental Research and Conductor Selection on Electromagnetic Environment of ±500kV DC Transmission Line at High Altitude
    Zhao L.
    Xiao B.
    Wang B.
    Yue S.
    Gao L.
    Dianwang Jishu/Power System Technology, 2021, 45 (02): : 794 - 801
  • [26] Thinking Outside the Box: Tennessee Valley Authority Uses the ACCR Conductor on a 500-kV Transmission Line
    Phillips, Jeffery
    Ryan, Mark
    Glass, Doyle
    ELECTRICAL TRANSMISSION AND SUBSTATION STRUCTURES 2015: TECHNICAL CHALLENGES AND INNOVATIVE SOLUTIONS IN GRID MODERNIZATION, 2015, : 227 - 236
  • [27] Development and Application of ±500 kV DC Transmission Line Arrester in China Power Grid
    Gu, Shanqiang
    Wan, Shuai
    Wang, Jian
    Chen, Jiahong
    Li, Tao
    IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (01) : 209 - 217
  • [28] Fundamental characteristics of overhead transmission line galloping determined by simulating calculation using equivalent single-conductor method
    Hokkaido Electric Power Co
    Electr Eng Jpn, 7 (11-28):
  • [29] Operation Recommendations for Tension Joints and Clamps on a 63 kV Overhead Transmission Line Conductor Based on Experimental Tests
    Samakosh, Jaber Dadashizadeh
    Enayati, Fardin
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2023, 51 (07) : 639 - 655
  • [30] Galloping characteristics of a 1000-kV UHV iced transmission line in the full range of wind attack angles
    Lou, Wenjuan
    Wu, Huihui
    Wen, Zuopeng
    Liang, Hongchao
    WIND AND STRUCTURES, 2022, 34 (02) : 173 - 183