Experimental study on thermal performance of a single-phase immersion cooling unit for high-density computing power data center

被引:1
作者
Sun, Xinshan [1 ]
Liu, Zhan [1 ]
Ji, Shenrui [1 ]
Yuan, Kaifeng [1 ]
机构
[1] China Univ Min & Technol, Sch Mech & Civil Engn, State Key Lab Intelligent Construct & Hlth Operat, Xuzhou 221116, Peoples R China
关键词
Single-phase immersion cooling; High-density computing power; Data center; Thermal performance; Power usage effectiveness;
D O I
10.1016/j.ijheatfluidflow.2024.109735
中图分类号
O414.1 [热力学];
学科分类号
摘要
Traditional air-cooling systems cannot meet special requirements of high-density computing power data centers (DCs). The single-phase immersion cooling (SPIC) is considered as one of the best ways to effectively cool highdensity computing power DC cabinets. In this study, a SPIC unit was experimentally investigated with dielectric fluid Noah 3000D under a designed heat load of 20 kW. The impact of the cooling water flow rate qv2 on the thermal characteristics, flow resistance and power consumption of the SPIC unit were investigated. The results show that the temperatures of both the coolant and cooling water decrease with the increase of qv2, but the temperature difference of coolant increases with the increase of qv2. An increase in coolant temperature difference means an increase in temperature non-uniformity. The increase in qv2 also leads to an increase in system flow resistance. In this experiment, the pressure loss of the heat exchanger and pipelines on the coolant side, account for about 56 % and 44 %, respectively. The power usage effectiveness of the cooling system in DC (cPUE) and coefficient of performance (COP) of the SPIC unit vary in the range of 1.08-1.09 and 5.69-7.21, respectively. Moreover, it is found that simply increasing qv2 cannot significantly improve the heat exchange of SPIC units, but will increase system's energy consumption to a certain extent. The present study mainly focuses on the laboratory experimental test on the SPIC unit, and the related conclusions are significant to the design and operation of SPIC units in high-density computing power DCs.
引用
收藏
页数:13
相关论文
共 26 条
  • [1] Brill K.G., 2007, white paper, P2
  • [2] Design of a single-phase immersion cooling system through experimental and numerical analysis
    Cheng, Chin-Chi
    Chang, Po-Chun
    Li, Hsing-Chieh
    Hsu, Fu-, I
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 160
  • [3] Indirect evaporative cooling: Past, present and future potentials
    Duan, Zhiyin
    Zhan, Changhong
    Zhang, Xingxing
    Mustafa, Mahmud
    Zhao, Xudong
    Alimohammadisagvand, Behrang
    Hasan, Ala
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (09) : 6823 - 6850
  • [4] Conjugate heat transfer for single phase immersion cooling of CPU
    Gajjar, Kathan
    Huang, Huei-Ping
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2023, 52
  • [5] Experimental research on the humidity in a passenger car cabin equipped with an air cooling system- development of a simplified model
    Gladyszewska-Fiedoruk, Katarzyna
    Teleszewski, Tomasz Janusz
    [J]. APPLIED THERMAL ENGINEERING, 2023, 220
  • [6] Resistance trends among clinical isolates in China reported from CHINET surveillance of bacterial resistance, 2005-2014
    Hu, F-P.
    Guo, Y.
    Zhu, D-M.
    Wang, F.
    Jiang, X-F.
    Xu, Y-C.
    Zhang, X-J.
    Zhang, C-X.
    Ji, P.
    Xie, Y.
    Kang, M.
    Wang, C-Q.
    Wang, A-M.
    Xu, Y-H.
    Shen, J-L.
    Sun, Z-Y.
    Chen, Z-J.
    Ni, Y-X.
    Sun, J-Y.
    Chu, Y-Z.
    Tian, S-F.
    Hu, Z-D.
    Li, J.
    Yu, Y-S.
    Lin, J.
    Shan, B.
    Du, Y.
    Han, Y.
    Guo, S.
    Wei, L-H.
    Wu, L.
    Zhang, H.
    Kong, J.
    Hu, Y-J.
    Ai, X-M.
    Zhuo, C.
    Su, D-H.
    Yang, Q.
    Jia, B.
    Huang, W.
    [J]. CLINICAL MICROBIOLOGY AND INFECTION, 2016, 22 : S9 - S14
  • [7] Natural and forced convection heat transfer characteristics of single-phase immersion cooling systems for data centers
    Huang, Yongping
    Ge, Junlei
    Chen, Yongping
    Zhang, Chengbin
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2023, 207
  • [8] Thermal management in legacy air-cooled data centers: An overview and perspectives
    Isazadeh, Amin
    Ziviani, Davide
    Claridge, David E.
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2023, 187
  • [9] Numerical analysis of single-phase liquid immersion cooling for lithium-ion battery thermal management using different dielectric fluids
    Jithin, K., V
    Rajesh, P. K.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 188
  • [10] Twenty first century cooling solution: Microchannel heat sinks
    Kadam, Sambhaji T.
    Kumar, Ritunesh
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2014, 85 : 73 - 92