Biomechanical assessment of anterior plate system, bilateral pedicle screw and transdiscal screw system for high-grade spondylolisthesis: a finite element study

被引:0
|
作者
Dhar, Utpal K. [1 ]
Sultan, Hadi [2 ]
Aghayev, Kamran [3 ]
Tsai, Chi-Tay [1 ]
Vrionis, Frank D. [4 ]
机构
[1] Florida Atlantic Univ, Dept Ocean & Mech Engn, Boca Raton, FL USA
[2] Florida Atlantic Univ, Charles E Schmidt Coll Med, Boca Raton, FL USA
[3] BHT Clin, Istanbul, Turkiye
[4] Boca Raton Reg Hosp, Marcus Neurosci Inst, Dept Neurosurg, Boca Raton, FL 33486 USA
来源
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY | 2024年 / 12卷
关键词
spondylolisthesis; finite element study; internal fixation technique; range of motion; interbody cage; LUMBAR SPINE; SURGICAL-TREATMENT; MECHANICAL-BEHAVIOR; LUMBOSACRAL SPINE; LOAD; DIRECTIONS; FIXATION;
D O I
10.3389/fbioe.2024.1491420
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Introduction Limited information regarding the biomechanical evaluation of various internal fixation techniques for high-grade L5-S1 spondylolisthesis is available. The stiffness of the operated segment and stress on the hardware can profoundly influence clinical outcomes and patient satisfaction. The objective of this study was to quantitatively investigate biomechanical profiles of various fusion methods used for high-grade spondylolisthesis by using finite element (FE) analysis.Methods An FE lumbar spine model of healthy spine was developed based on a patient's CT scan. High-grade (III-IV) spondylolisthesis (SP model) was created by sliding L5 anteriorly and modifying L5-S1 facet joints. Three treatment scenarios were created by adding various implants to the model. These scenarios included L5-S1 interbody cage in combination with three different fixation methods-the anterior plate system (APS), bilateral pedicle screw system (BPSS), and transdiscal screw system (TSS). Range of motion (ROM), von Mises stress on cage, internal fixation as well as on the adjacent annuli were obtained and compared. The resistance to slippage was investigated by applying shear force on L5 vertebra and measuring its displacement regarding to S1.Results Under different loading conditions all treatment scenarios showed substantial reduction of ROM in comparison with SP model. No notable differences in ROM were observed between treatment models. There was no notable difference in cage stress among models. The von Mises stress on the internal fixation in the TSS model was less than in APS and BPSS. The TSS model demonstrated superior resistance to shear load compared to APS and BPSS. No discernible difference was observed between the SP, APS, BPSS, and TSS models when compared the ROM for adjacent level L4-L5. TSS's von Mises stress of the adjacent annulus was higher than in APS and BPSS.Conclusions The TSS model exhibited biomechanical superiority over the APS and BPSS models.
引用
收藏
页数:12
相关论文
共 42 条
  • [31] Comparative Biomechanical Analysis of Anterior Process Locking Plate Alone versus Combined with Percutaneous Cannulated Screw Fixation for Sanders Type II Calcaneal Fractures: A Finite Element Study
    Ma, Rongji
    Shaikh, Atik Badshah
    Zhang, Qinxin
    Su, Xiuyun
    Wang, Yonghua
    Pan, Fuhai
    Chen, Jianwen
    He, Kai
    MEDICAL SCIENCE MONITOR, 2023, 29
  • [32] Thoracic vertebra fixation with a novel screw-plate system based on computed tomography imaging and finite element method
    Zhang, Wencan
    Zhao, Junyong
    Jiang, Xiujuan
    Li, Le
    Yu, Chenxiao
    Zhao, Yuefeng
    Si, Haipeng
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2020, 187
  • [33] Design of a novel lateral mass screw-plate system for the treatment of unstable atlas fractures: a finite element analysis
    Niu, He-Gang
    Zhang, Jing-Jing
    Yan, Yi-Zhu
    Zhao, Cheng-Kun
    Yang, Kun
    Zhang, Yin-Shun
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01)
  • [34] Pilot study of oblique lumbar interbody fusion using mobile percutaneous pedicle screw and validation by a three-dimensional finite element assessment
    Eguchi, Yawara
    Orita, Sumihisa
    Yamada, Hiroyuki
    Suzuki, Munetaka
    Yamanaka, Hajime
    Tamai, Hiroshi
    Inage, Kazuhide
    Narita, Miyako
    Shiga, Yasuhiro
    Inoue, Masahiro
    Norimoto, Masaki
    Umimura, Tomotaka
    Sato, Takashi
    Suzuki, Masahiro
    Enomoto, Keigo
    Koda, Masao
    Furuya, Takeo
    Maki, Satoshi
    Hirosawa, Naoya
    Aoki, Yasuchika
    Nakamura, Junichi
    Hagiwara, Shigeo
    Akazawa, Tsutomu
    Takahashi, Hiroshi
    Takahashi, Kazuhisa
    Shiko, Yuki
    Kawasaki, Yohei
    Ohtori, Seiji
    JOURNAL OF CLINICAL NEUROSCIENCE, 2020, 76 : 74 - 80
  • [35] A comparison of the influence of three different lumbar interbody fusion approaches on stress in the pedicle screw fixation system: Finite element static and vibration analyses
    Fan, Wei
    Guo, Li-Xin
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2019, 35 (03)
  • [36] Comparison of locking and non-locking reconstruction plate-screw system in lateral mandibular defects by finite element analysis
    Muftuoglu, G.
    Bayram, B.
    Aydin, P.
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2021, 122 (04) : E65 - E69
  • [37] An Optimization Study of the Screw Orientation on the Interfacial Strength of the Anterior Lumbar Plate System Using Neurogenetic Algorithms and Experimental Validation
    Lee, Chian-Her
    Hsu, Ching-Chi
    Dinh Cong Huy
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2014, 136 (11):
  • [38] Establishing finite element model credibility of a pedicle screw system under compression-bending: An end-to-end example of the ASME V&V 40 standard
    Nagaraja, Srinidhi
    Loughran, Galyna
    Baumann, Andrew P.
    Kartikeya, Kumar
    Horner, Marc
    METHODS, 2024, 225 : 74 - 88
  • [39] A pedicle screw system and a lamina hook system provide similar primary and long-term stability: a biomechanical in vitro study with quasi-static and dynamic loading conditions
    Wilke, Hans-Joachim
    Kaiser, Dominik
    Volkheimer, David
    Hackenbroch, Carsten
    Pueschel, Klaus
    Rauschmann, Michael
    EUROPEAN SPINE JOURNAL, 2016, 25 (09) : 2919 - 2928
  • [40] Biomechanical assessment of composite versus metallic intramedullary nailing system in femoral shaft fractures: A finite element study
    Samiezadeh, Saeid
    Avval, Pouria Tavakkoli
    Fawaz, Zouheir
    Bougherara, Habiba
    CLINICAL BIOMECHANICS, 2014, 29 (07) : 803 - 810