Biomechanical assessment of anterior plate system, bilateral pedicle screw and transdiscal screw system for high-grade spondylolisthesis: a finite element study

被引:0
|
作者
Dhar, Utpal K. [1 ]
Sultan, Hadi [2 ]
Aghayev, Kamran [3 ]
Tsai, Chi-Tay [1 ]
Vrionis, Frank D. [4 ]
机构
[1] Florida Atlantic Univ, Dept Ocean & Mech Engn, Boca Raton, FL USA
[2] Florida Atlantic Univ, Charles E Schmidt Coll Med, Boca Raton, FL USA
[3] BHT Clin, Istanbul, Turkiye
[4] Boca Raton Reg Hosp, Marcus Neurosci Inst, Dept Neurosurg, Boca Raton, FL 33486 USA
来源
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY | 2024年 / 12卷
关键词
spondylolisthesis; finite element study; internal fixation technique; range of motion; interbody cage; LUMBAR SPINE; SURGICAL-TREATMENT; MECHANICAL-BEHAVIOR; LUMBOSACRAL SPINE; LOAD; DIRECTIONS; FIXATION;
D O I
10.3389/fbioe.2024.1491420
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Introduction Limited information regarding the biomechanical evaluation of various internal fixation techniques for high-grade L5-S1 spondylolisthesis is available. The stiffness of the operated segment and stress on the hardware can profoundly influence clinical outcomes and patient satisfaction. The objective of this study was to quantitatively investigate biomechanical profiles of various fusion methods used for high-grade spondylolisthesis by using finite element (FE) analysis.Methods An FE lumbar spine model of healthy spine was developed based on a patient's CT scan. High-grade (III-IV) spondylolisthesis (SP model) was created by sliding L5 anteriorly and modifying L5-S1 facet joints. Three treatment scenarios were created by adding various implants to the model. These scenarios included L5-S1 interbody cage in combination with three different fixation methods-the anterior plate system (APS), bilateral pedicle screw system (BPSS), and transdiscal screw system (TSS). Range of motion (ROM), von Mises stress on cage, internal fixation as well as on the adjacent annuli were obtained and compared. The resistance to slippage was investigated by applying shear force on L5 vertebra and measuring its displacement regarding to S1.Results Under different loading conditions all treatment scenarios showed substantial reduction of ROM in comparison with SP model. No notable differences in ROM were observed between treatment models. There was no notable difference in cage stress among models. The von Mises stress on the internal fixation in the TSS model was less than in APS and BPSS. The TSS model demonstrated superior resistance to shear load compared to APS and BPSS. No discernible difference was observed between the SP, APS, BPSS, and TSS models when compared the ROM for adjacent level L4-L5. TSS's von Mises stress of the adjacent annulus was higher than in APS and BPSS.Conclusions The TSS model exhibited biomechanical superiority over the APS and BPSS models.
引用
收藏
页数:12
相关论文
共 42 条
  • [21] Biomechanical evaluation of a new pedicle screw-based posterior dynamic stabilization device (Awesome Rod System) - a finite element analysis
    Chen-Sheng Chen
    Chang-Hung Huang
    Shih-Liang Shih
    BMC Musculoskeletal Disorders, 16
  • [22] Biomechanical evaluation of a new pedicle screw-based posterior dynamic stabilization device (Awesome Rod System) - a finite element analysis
    Chen, Chen-Sheng
    Huang, Chang-Hung
    Shih, Shih-Liang
    BMC MUSCULOSKELETAL DISORDERS, 2015, 16
  • [23] Anterior cervical transpedicular screw fixation system in subaxial cervical spine: A finite element comparative study
    Li, Jie
    Gan, Kaifeng
    Chen, Binhui
    Chen, Yilei
    Hong, Jinjiong
    Bei, Dikai
    Fan, Tengdi
    Zheng, Minzhe
    Zhao, Liujun
    Zhao, Fengdong
    MEDICINE, 2022, 101 (29) : E29316
  • [24] Screw angulation affects bone-screw stresses and bone graft load sharing in anterior cervical corpectomy fusion with a rigid screw-plate construct: a finite element model study
    Hussain, Mozammil
    Natarajan, Raghu N.
    Fayyazi, Amir H.
    Braaksma, Brian R.
    Andersson, Gunnar B. J.
    An, Howard S.
    SPINE JOURNAL, 2009, 9 (12) : 1016 - 1023
  • [25] A spontaneous anterior fusion of lumbar spine after posterolateral lumbar fusion with pedicle screw-plate system
    Kraiwattanapong, Chaiwat
    Chandrsawang, Issara
    Keorochana, Gun
    Rajinda, Panupol
    Chanplakorn, Pongsthorn
    Leelapattana, Pittavat
    Udomsubpayakul, Umaporn
    Lertudomphonwanit, Thamrong
    BMC MUSCULOSKELETAL DISORDERS, 2025, 26 (01)
  • [26] Effect of Calcar Screw in Locking Compression Plate System for Osteoporotic Proximal Humerus Fracture: A Finite Element Analysis Study
    Lee, Jung-Soo
    Kim, Jong Hoon
    Kim, Kwang Gi
    Yoon, Yong-Cheol
    BIOMED RESEARCH INTERNATIONAL, 2022, 2022
  • [27] Experimental study on the biomechanical stability of complex acetabular fractures in the quadrilateral area: application of a dynamic anterior titanium-plate screw system
    Wu, Yong-De
    Mei, Xian-Zhong
    Wu, Wei-Fei
    Zhang, Hong-Xi
    Liang, Jie
    Cai, Xian-Hua
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [28] Mechanical evaluation for the finite element analysis of intramedullary nailing and plate screw system used in humerus transverse fractures
    Akkurt, Ekrem
    Yildirim, Mucahid
    Erenler, Ferhat
    Tosun, Osman Mucahit
    Akkurt, Mustafa Ferit
    Akkurt, Burcu
    Sen, Zafer
    Olcar, Ahmet Hamdi
    JOURNAL OF ORTHOPAEDICS, 2025, 61 : 66 - 71
  • [29] Original Biomechanical analysis of a novel bone cement bridging screw system for the treatment of Kummell disease: a finite element analysis
    Wang, Biao
    Zhan, Yi
    Bai, Yesheng
    Kong, Lingbo
    Li, Liang
    Zhang, Haiping
    He, Simin
    Hao, Dingjun
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2022, 14 (10): : 7052 - 7062
  • [30] Effect of a pedicle-screw-based motion preservation system on lumbar spine biomechanics: A probabilistic finite element study with subsequent sensitivity analysis
    Rohlmann, Antonius
    Boustani, Hadi Nabil
    Bergmann, Georg
    Zander, Thomas
    JOURNAL OF BIOMECHANICS, 2010, 43 (15) : 2963 - 2969