Neutron holography measurement using multi array detector

被引:0
|
作者
Hayashi, Kouichi [1 ]
Ohoyama, Kenji [1 ]
Orimo, Shin-Ichi [1 ]
Nakamori, Yuko [1 ]
Takahashi, Hideyuki [2 ]
Shibata, Kaoru [3 ]
机构
[1] Institute for Materials Research, Tohoku University, Sendai 980-8577, Japan
[2] Graduate School for Environmental Science, Tohoku University, Sendai 980-8579, Japan
[3] J-PARC Center, Japan Atomic Energy Agency, Tokai, Ibaraki 319-1195, Japan
来源
Japanese Journal of Applied Physics | 2008年 / 47卷 / 4 PART 1期
关键词
Atomic-resolution neutron holography was carried out utilizing the powder diffrcatometer in JRR-3M reactor. Spherically emitted neutrons around a PdH 0.78 single crystal produced by incoherent neutron-proton scattering; which formed a hologram; were efficiently collected using multi array 3He detectors. In addition to the hologram data; strong undulation due to the elastic thermal scattering was observed. To exclude this effect; the thermal scattering pattern was calculated and subtracted from the measured data. From the resulting hologram data; neighboring Pd and H nuclei images were successfully reconstructed. © 2008 The Japan Society of Applied Physics;
D O I
暂无
中图分类号
学科分类号
摘要
Journal article (JA)
引用
收藏
页码:2291 / 2293
相关论文
共 50 条
  • [21] The NOMAD instrument neutron detector array at the SNS
    Beal, J. D.
    Berry, K. D.
    Riedel, R. A.
    Funk, L. L.
    Reynolds, W. B.
    Diawara, Y.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1018
  • [22] Electron-Neutron Detector Array (ENDA)
    Li, Bing-Bing
    Cui, Shu-Wang
    Shi, Cong
    Yang, Fan
    Zhang, Liang-Wei
    Liu, Ye
    Ma, Xin-Hua
    Gao, Wei
    Yin, Li-Qiao
    Stenkin, Yu, V
    Kuleshov, D. A.
    Levochkin, K. R.
    Shchegolev, O. B.
    Chen, Tian-Lu
    Danzengluobu
    Liu, Mao-Yuan
    Xiao, Di-Xuan
    PHYSICS OF ATOMIC NUCLEI, 2021, 84 (06) : 941 - 946
  • [23] Readout electronics for thermal neutron detector array
    Dong, Chunhui
    Huang, Qichang
    Ma, Xiao
    Yao, Jiadong
    Xiong, Hao
    Shen, Fengzhao
    Chen, Jian
    Zhang, Jinglong
    Zhou, Rong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 946
  • [25] A thermal neutron detector array communication protocol
    Huang, Qi-Chang
    Chen, Qi
    Dong, Chunhui
    JOURNAL OF INSTRUMENTATION, 2022, 17 (12):
  • [26] Study of Boron-Lined Straw-Tube Detector Array for Neutron Scattering Measurement
    Chen, Cai
    Yang, Yigang
    Zhu, Shounuo
    Huang, Weiqi
    Gong, Hui
    Wang, Xuewu
    Li, Yuanjing
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 176 - 179
  • [27] DIRECT MEASUREMENT OF NEUTRON DETECTOR EFFICIENCIES
    RIDDLE, RAJ
    HARRISON, GH
    ROOS, PG
    SALTMARSH, MJ
    NUCLEAR INSTRUMENTS & METHODS, 1974, 121 (03): : 445 - 447
  • [28] MEASUREMENT OF NEUTRON CAPTURE RESONANCES USING AN (N, GAMMA) SCINTILLATION DETECTOR
    ALBERT, RD
    GAERTTNER, ER
    PHYSICAL REVIEW, 1953, 91 (02): : 451 - 451
  • [29] MEASUREMENT OF FAST-NEUTRON FLUENCE USING NUCLEAR TRACK DETECTOR
    RAM, S
    BOSE, SK
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1986, 12 (1-6): : 577 - 579
  • [30] MEASUREMENT OF FAST NEUTRON FLUENCE USING NUCLEAR TRACK DETECTOR.
    Ram, S.
    Bose, S.K.
    Nuclear tracks, 1985, 12 (1-6): : 577 - 579