Design evolution of indirect evaporative air-cooling system through multiple configurations for the enhancement of heat and mass transfer mechanism

被引:0
|
作者
Rasheed, Sabir [1 ]
Ali, Muzaffar [2 ,3 ]
Ali, Hassan [4 ]
Sheikh, Nadeem Ahmed [5 ]
Li, Guiqiang [3 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Shanghai 200240, Peoples R China
[2] Univ Engn & Technol, Energy Engn Dept, Taxila 47050, Pakistan
[3] Univ Sci & Technol China, Dept Thermal Sci & Energy Engn, Hefei 230026, Peoples R China
[4] Univ Birmingham, Sch Chem Engn, Dubai, U Arab Emirates
[5] Int Islamic Univ, Dept Mech Engn, Islamabad 44000, Pakistan
关键词
Indirect evaporative cooler; Maisotsenko cycle; Energy efficiency ratio; Thermal effectiveness; SDGs; SOLAR-ASSISTED DESICCANT; CROSS-FLOW; EXCHANGER; COOLER;
D O I
10.1016/j.icheatmasstransfer.2024.108393
中图分类号
O414.1 [热力学];
学科分类号
摘要
Cooling demand is escalating because of the climate change and population growth in emerging nations. One of the today's concerns is meeting exponentially raising cooling requirements. Additionally, sustainable development goals (SDGs) such as SDG 03, SDG 07, and SDG 13 emphasize the need of environmentally friendly cooling techniques for human thermal comfort. Therefore, it is essential to develop novel approaches for cooling indoor spaces. The current study presents the design evolution of a Maisotsenko cycle-based indirect evaporative aircooling system (IEC), with a focus on air-water flow patterns, structural design, and the improved energy efficiency by utilizing locally accessible low-cost polymeric materials. This study also comprises a thorough experimental investigation of an indirect evaporative cooling system by developing multiple configurations (Config) of heat and mass exchangers at the stack level. The experimental findings demonstrate that thermal efficiency of the IECs enhances by increasing the ambient air temperature and wetted area in wet channels. Overall, the resultant wetbulb and dewpoint effectiveness of Config 1-Config 6 vary from 0.29 to 1.12 and 0.22 to 0.86, respectively. Moreover, the configuration 6 has the maximum cooling capacity, coefficient of performance (COP), and energy efficiency ratio (EER) of 2.07 kW, 6.91, and 23.59, respectively under control conditions by utilizing the air conditioning laboratory unit. The results clearly indicate that proposed design configurations incorporating polymeric materials, having high CC and EER, are more effective for air-cooling in hot and dry climate conditions.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Enhancement in air-cooling through integration of desiccant coated channels with cross-flow indirect evaporative heat and mass exchanger
    Ali, Muzaffar
    Rasheed, Sabir
    Mohsin, Mohammad
    He, Suoying
    Arici, Muslum
    Li, Guiqiang
    ENERGY, 2025, 314
  • [2] An approach to the analysis of heat and mass transfer characteristics in indirect evaporative cooling with counter flow configurations
    Wan, Yangda
    Ren, Chengqin
    Xing, Li
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 108 : 1750 - 1763
  • [3] An analytical model for the heat and mass transfer processes in indirect evaporative cooling with parallel/counter flow configurations
    Ren, CQ
    Yang, HX
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2006, 49 (3-4) : 617 - 627
  • [4] Numerical Study of Heat and Mass Transfer Process in the Maisotsenko Cycle for Indirect Evaporative Air Cooling
    Anisimov, Sergey
    Pandelidis, Demis
    Maisotsenko, Valeriy
    HEAT TRANSFER ENGINEERING, 2016, 37 (17) : 1455 - 1465
  • [5] Optimal design of a regenerative heat and mass exchanger for indirect evaporative cooling
    Fakhrabadi, Farbod
    Kowsary, Farshad
    APPLIED THERMAL ENGINEERING, 2016, 102 : 1384 - 1394
  • [6] SIMULATION OF HEAT AND MASS TRANSFER IN INDIRECT EVAPORATIVE AIR-COOLER
    Barakov, A. V.
    Kozhukhov, N. N.
    Prutskikh, D. A.
    Dubanin, V. Yu.
    SCIENTIFIC HERALD OF THE VORONEZH STATE UNIVERSITY OF ARCHITECTURE & CIVIL ENGINEERING CONSTRUCTION & ARCHITECTURE, 2016, (02): : 24 - 29
  • [7] Optimization criteria for the performance of heat and mass transfer in indirect evaporative cooling systems
    Yuan Fang
    Chen Qun
    CHINESE SCIENCE BULLETIN, 2012, 57 (06): : 687 - 693
  • [8] Optimization criteria for the performance of heat and mass transfer in indirect evaporative cooling systems
    YUAN Fang & CHEN Qun Key Laboratory for Thermal Science and Power Engineering of Ministry of Education
    Chinese Science Bulletin, 2012, 57 (06) : 690 - 696
  • [9] Heat mass transfer analog of air-cooling rotating dise with naphthalene sublimation
    Cao, Yuzhang
    Lin, Yuzhen
    Feng, Huazhong
    Xu, Guoqing
    Qiu, Xuguang
    Journal of Aerospace Power/Hangkong Dongli Xuebao, 1993, 8 (03):
  • [10] Heat- and mass-transfer procesess in indirect evaporative air conditioners through the maisotsenko cycle
    Anisimov S.
    Pandelidis D.